<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>standard technický &#8211; PROFESIS</title>
	<atom:link href="https://profesis.ckait.cz/klicova-slova/standard-technicky/feed/" rel="self" type="application/rss+xml" />
	<link>https://profesis.ckait.cz</link>
	<description>Profesní informační systém ČKAIT</description>
	<lastBuildDate>Fri, 31 Jul 2026 12:36:13 +0000</lastBuildDate>
	<language>cs</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://profesis.ckait.cz/wp-content/uploads/2020/05/cropped-favicon-profesis-v4-jpg-32x32.jpg</url>
	<title>standard technický &#8211; PROFESIS</title>
	<link>https://profesis.ckait.cz</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TS 01 &#8211; Stanovení minimální návrhové světlé výšky místností (Technický standard ČKAIT)</title>
		<link>https://profesis.ckait.cz/dokumenty-ckait/ts-01/</link>
		
		<dc:creator><![CDATA[CKAIT Profesis Admin]]></dc:creator>
		<pubDate>Tue, 07 Jul 2020 11:57:39 +0000</pubDate>
				<guid isPermaLink="false">https://profesis.ckait.cz/?post_type=dokumenty&#038;p=1378</guid>

					<description><![CDATA[Stanovení bezpečné návrhové světlé výšky tak, aby po realizaci byly bezpečně splněny požadavky právních předpisů. Navýšení je stanoveno na základě výpočtového postupu mezních geometrických odchylek světlé výšky místností. Technický standard je určen pro projektanty i zhotovitele.]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>Autoři:</strong> <a href="/autori/klecka-jan/">Ing. Jan Klečka</a>, <a href="/autori/vesela-linda/">Ing. Linda Veselá, Ph.D.</a></p>



<p class="wp-block-paragraph"><strong>Stav:</strong>  verze 3, vydání červen 2026</p>



<p class="wp-block-paragraph"><strong>Účinnost:</strong>&nbsp;od 1. 7. 2026</p>



<div style="height:30px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph"><strong>JEDNOTLIVÁ VYDÁNÍ:</strong></p>



<p class="wp-block-paragraph"><strong>Účinnost verze 3:</strong> od 1. 7. 2026</p>



<div class="wp-block-file"><a id="wp-block-file--media-a46e7de5-d28e-4d18-9f97-273bff79e741" href="https://profesis.ckait.cz/wp-content/uploads/2026/07/ts01-ckait-v3-od-20260701-sestaveni-20260729.pdf">TS 01-2026 ČKAIT ve formátu PDF ke stažení</a><a href="https://profesis.ckait.cz/wp-content/uploads/2026/07/ts01-ckait-v3-od-20260701-sestaveni-20260729.pdf" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-a46e7de5-d28e-4d18-9f97-273bff79e741">Stáhnout</a></div>



<div style="height:30px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph"><strong><a href="/upozorneni-k-textum">Upozornění k textu</a></strong></p>



<hr class="wp-block-separator aligncenter has-alpha-channel-opacity is-style-wide"/>



<p class="wp-block-paragraph"><strong>PŘEDMLUVA</strong></p>



<p class="wp-block-paragraph">Návrh světlých výšek místností musí respektovat požadavky na minimální předepsané výšky podle právních předpisů, případně i podle technických norem. Zároveň návrh musí respektovat technologické možnosti výstavby jednotlivých konstrukcí – geometrické odchylky.</p>



<p class="wp-block-paragraph">Soustava českých technických norem pro geometrickou přesnost předpokládá, že projektant určí funkční geometrické parametry pro konkrétní stavbu. Výpočtem je ověřuje v tzv. „geometrickém plánu“ v DPS, přičemž funkční geometrické parametry mají být stanoveny především pro kritické prvky, to znamená pro konstrukce, jejichž geometrická přesnost je důležitá pro provádění následných prací, jako jsou technologie vyžadující vysokou přesnost, specifické konstrukce apod.</p>



<p class="wp-block-paragraph">Předpokladem je, že projektanti zapracují odchylky geometrické přesnosti především při tvorbě prostorových parametrů stavebních konstrukcí, čímž by mělo být zajištěno, že budou dodrženy minimální rozměrové požadavky na dokončené konstrukce.</p>



<p class="wp-block-paragraph">Aby byly dodrženy minimální rozměrové požadavky na dokončené konstrukce, měly by být odchylky geometrické přesnosti stanoveny podle požadavků technických norem pro provádění jednotlivých částí stavebních konstrukcí anebo pro jejich navrhování.</p>



<p class="wp-block-paragraph">Cílem tohoto standardu je stanovení bezpečné návrhové světlé výšky tak, aby po realizaci byly bezpečně splněny požadavky právních předpisů. Navýšení je stanoveno na základě výpočtového postupu mezních geometrických odchylek světlé výšky místností.</p>



<p class="wp-block-paragraph">Výpočet uvažuje doporučené odchylky geometrické přesnosti prováděcích/návrhových norem. Dodavatelé stavebních konstrukcí výpočet využijí pro stanovení rizik v rámci kontroly projektové dokumentace.</p>



<p class="wp-block-paragraph">Technický standard slouží i pro stanovení výšky stavby, uváděné pro územní nebo stavební řízení.</p>



<hr class="wp-block-coblocks-dynamic-separator is-style-wide tenky-oddelovac is-style-fullwidth" style="height:20px"/>



<p class="wp-block-paragraph"><strong>Technický standard ČKAIT</strong> je doporučený dokument obsahující technické informace, které mají být respektovány, a instrukce popisující činnost, která se má provést. Stanovuje technické požadavky, které má stavební konstrukce, proces, nebo služba splňovat. Technický standard může také uvádět postupy, jejichž pomocí lze určit, zda jsou dané požadavky splněny.</p>



<p class="wp-block-paragraph">Technické standardy ČKAIT nejsou obecně závazné, jsou to však odborně kvalifikované předpisy, na&nbsp;které se mohou odkazovat smluvní strany při specifikaci předmětu smlouvy a podmínek jejího plnění nebo státní autorita ve svých obecně závazných předpisech.</p>



<p class="wp-block-paragraph"><strong>OBSAH</strong></p>


<figure class="wp-block-table">
<table style="border-style: hidden;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="border-style: hidden; width: 15px; text-align: right;"> </td>
<td style="border-style: hidden;"><a href="#predmluva"><strong>Předmluva</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>1</strong></td>
<td style="border-style: hidden;"><a href="#1"><strong>Předmět</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>2</strong></td>
<td style="border-style: hidden;"><a href="#2"><strong>Termíny a definice</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.1</td>
<td style="border-style: hidden;"><a href="#2-1">Světlá výška (Headroom)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.2</td>
<td style="border-style: hidden;"><a href="#2-2">Konstrukční výška (Construction height)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.3</td>
<td style="border-style: hidden;"><a href="#2-3">Mezní odchylka (Permitted deviation)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.4</td>
<td style="border-style: hidden;"><a href="#2-4">Tolerance (Tolerance)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>3</strong></td>
<td style="border-style: hidden;"><a href="#3"><strong>Odchylky světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>4</strong></td>
<td style="border-style: hidden;"><a href="#4"><strong>Doporučené návrhové hodnoty navýšení světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>5</strong></td>
<td style="border-style: hidden;"><a href="#5"><strong>Výpočet doporučené světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>6</strong></td>
<td style="border-style: hidden;"><a href="#6"><strong>Doporučené hodnoty pro výpočet světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.1</td>
<td style="border-style: hidden;"><a href="#6-1">Odchylky nosné konstrukce</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.2</td>
<td style="border-style: hidden;"><a href="#6-2">Odchylka tloušťky podlahy (Δt<sub>p</sub>)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.3</td>
<td style="border-style: hidden;"><a href="#6-3">Povrchová úprava spodního líce stropu (t<sub>ps</sub>)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.4</td>
<td style="border-style: hidden;"><a href="#6-4">Podhled (t<sub>ps</sub>)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.5</td>
<td style="border-style: hidden;"><a href="#6-5">Průhyb stropní konstrukce (p)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>7</strong></td>
<td style="border-style: hidden;"><a href="#7"><strong>Využití pomůcky pro stanovení návrhové světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>8</strong></td>
<td style="border-style: hidden;"><a href="#8"><strong>Měření světlé výšky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>9</strong></td>
<td style="border-style: hidden;"><a href="#9"><strong>Literatura, citované normy a předpisy</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"> </td>
<td style="border-style: hidden;">
<p><strong><a href="#Příloha-1">Příloha 1 – výběr požadovaných světlých výšek podle předpisů</a></strong></p>
<p><a href="#Příloha-2"><strong>Příloha 2 – pomocný výpočet pro stanovení návrhové světlé výšky</strong></a></p>
</td>
</tr>
</tbody>
</table>
</figure>


<hr class="wp-block-separator has-css-opacity is-style-wide"/>



<h3 id="1" class="wp-block-heading">1 PŘEDMĚT</h3>



<p class="wp-block-paragraph">V rámci tohoto dokumentu jsou popsány postupy výpočtu mezních geometrických odchylek světlé výšky pro běžné stavby, pokud projektant nenavrhne podrobněji. Veškeré použité podklady vycházejí z&nbsp;požadavků a&nbsp;definic, technických požadavků na stavby a&nbsp;technických norem.</p>



<p class="wp-block-paragraph">Nedílnou součástí dokumentu je program pro výpočet a&nbsp;kontrolu odchylek světlých výšek ve&nbsp;formátu&nbsp;XLSX.</p>



<p class="wp-block-paragraph">Tento technický standard ČKAIT platí pro návrh a&nbsp;kontrolu navrhované světlé výšky navrhovaných místností pozemních staveb. Pro stavební úpravy stávajících budov, pro konstrukce nestandardních tvarů (např.&nbsp;klenby), schodišť nebo jiných šikmých konstrukcí lze tento standard použít přiměřeně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="2" class="wp-block-heading">2 TERMÍNY A DEFINICE</h3>



<p class="wp-block-paragraph">Pro účely dokumentu platí dále uvedené termíny a definice.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="2-1" class="wp-block-heading">2.1&nbsp;SVĚTLÁ VÝŠKA (HEADROOM)</h3>



<p class="wp-block-paragraph">Světlou výškou se rozumí svislá vzdálenost mezi horním lícem nášlapné vrstvy podlahy a rovinou spodního líce stropu nebo zavěšeného stropního podhledu v jednom podlaží. U trámových stropů s viditelnými trámy se měří po&nbsp;spodní líc podhledu stropu mezi trámy, u stropů klenbových do spodního líce vrcholu klenby. U&nbsp;šikmých stropů se světlá výška zjišťuje k nejvyššímu bodu zešikmení.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="2-2" class="wp-block-heading">2.2&nbsp;KONSTRUKČNÍ VÝŠKA (CONSTRUCTION HEIGHT)</h3>



<p class="wp-block-paragraph">Konstrukční výška je výška podlaží vymezená dvěma nad sebou následujícími vrchními líci nosné konstrukce stropu nebo výška od horního líce základové konstrukce k&nbsp;vrchními líci nosné konstrukce nejnižšího stropu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="2-3" class="wp-block-heading">2.3&nbsp;MEZNÍ ODCHYLKA (PERMITTED DEVIATION)</h3>



<p class="wp-block-paragraph">Mezní odchylka je parametr geometrické přesnosti, který může nabývat kladných i&nbsp;záporných hodnot (bývá většinou uváděn se znaménkem „±“, např.&nbsp;±5 mm&nbsp;nebo +2 mm&nbsp;/ -1 mm). Skutečný rozměr může být o&nbsp;tuto hodnotu zmenšen, resp. zvětšen vzhledem k&nbsp;hodnotě základního rozměru. Mezní odchylkou se vyjadřují především odchylky délkových rozměrů, půdorysné polohy, výšky, umístění otvorů apod.polohy, výšky, umístění otvorů apod.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="2-4" class="wp-block-heading">2.4&nbsp;TOLERANCE (TOLERANCE)</h3>



<p class="wp-block-paragraph">Tolerance je absolutní hodnota rozdílu mezních odchylek (např.&nbsp;tolerance mezní odchylky ±5 mm&nbsp;je 10&nbsp;mm). Hodnota uvedená v&nbsp;normě ČSN bez znaménka „±“ (tolerance v&nbsp;absolutní hodnotě) může nabývat kladných a&nbsp;záporných hodnot pouze tehdy, pokud se vydělí dvěma (např.&nbsp;tolerance 9 mm&nbsp;nemůže nabývat hodnot ±9 mm, ale může nabývat hodnot ±4,5 mm).</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="3" class="wp-block-heading">3 ODCHYLKY SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">(1) Skutečné světlé výšky místností mohou být ovlivněny především těmito geometrickými parametry, zejména:</p>



<p class="wp-block-paragraph">a) odchylkou konstrukční výšky,<br>b) skutečnou tloušťkou podlah,<br>c) průhybem vodorovných konstrukcí.</p>



<p class="wp-block-paragraph">(2) Při návrhu a provádění nosné konstrukce je třeba počítat s geometrickou přesností nejen samotné nosné konstrukce, ale i s odchylkami podlahy, podhledu, povrchové úpravy stropu a průhybu nosné konstrukce. K minimální světlé výšce je tak potřeba připočíst přípustné odchylky skutečného provedení nosných konstrukcí, podlahy, navrhovaného průhybu stropů a povrchové úpravy spodního líce stropní konstrukce.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img fetchpriority="high" decoding="async" width="488" height="263" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/crop-0-0-488-263-0-ts01_3_1.gif" alt="" class="wp-image-1071"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 3.1</em>&nbsp;&nbsp;Stanovení navrhované světlé výšky místností</p>



<p class="wp-block-paragraph">(3) Světlá výška musí být navržena s rezervou na odchylky při provedení konstrukcí tak, aby byly dodrženy předepsané minimální technické požadavky při použití běžných technologií realizace.</p>



<p class="wp-block-paragraph">(4) Podkladem pro výpočet odchylky světlé výšky jsou odchylky rozměrů doporučené v ČSN pro navrhování nebo provádění jednotlivých konstrukcí. Pokud není odchylka uvedena v normě, stanoví se individuálně.</p>



<p class="wp-block-paragraph">(5) Pro snadnější stanovení odchylky světlé výšky jsou níže uvedeny doporučené hodnoty přípustných odchylek uvažovaných geometrických parametrů včetně případného odkazu na příslušný technický dokument, ve kterém jsou uvedeny.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="4" class="wp-block-heading">4 DOPORUČENÉ NÁVRHOVÉ HODNOTY NAVÝŠENÍ SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">(1) Návrhová hodnota světlé výšky se stanoví jako požadovaná minimální hodnota světlé výšky plus doporučené navýšení uvedené v tab. 4.1, pokud není navrženo podrobněji. Výsledná hodnota na kótě ve výkresu bude odpovídat návrhové hodnotě světlé výšky plus doporučené navýšení plus povrchová úprava spodního líce stropu (pokud se nekótuje samostatně, více v <a href="#6-3">kap.&nbsp;6.3</a>). Návrhová hodnota konstrukční výšky podlaží se stanoví podle&nbsp;<a href="#3">kap. 3</a>.</p>



<p class="wp-block-paragraph">(2) Protože v prvních fázích projektových prací (studie, DÚR, DSP) nejsou často známy všechny údaje potřebné ke stanovení bezpečného navýšení světlé výšky, jsou v tabulkách uvedeny doporučené minimální rezervy.</p>



<p class="wp-block-paragraph">(3) U konstrukcí s rozpětím větším než 8 m, se postupuje individuálně, např. podle výpočtu uvedeného v&nbsp;<a href="#5">kap. 5</a>.</p>



<p class="wp-block-paragraph"><em>Tab. 4.1</em>&nbsp;&nbsp;Doporučené zvětšení světlé výšky [mm]</p>



<table style="border-collapse: collapse; width: 100%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td rowspan="2"><strong data-rich-text-format-boundary="true">Konstrukční výška <em>h</em><sub>kv</sub></strong></td>
<td style="text-align: center;" colspan="4"><strong data-rich-text-format-boundary="true">Rozpětí stropu <em>L</em> [m]</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">≤ 3,0</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">≤ 4,0</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">≤ 6,0</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">≤ 8,0</strong></td>
</tr>
<tr>
<td><em>h</em><sub>kv</sub>&nbsp;≤ 4 m</td>
<td style="text-align: center;">40</td>
<td style="text-align: center;">45</td>
<td style="text-align: center;">50</td>
<td style="text-align: center;">55</td>
</tr>
<tr>
<td>4 m &lt; <em>h</em><sub>kv</sub>&nbsp;≤ 8 m</td>
<td style="text-align: center;">45</td>
<td style="text-align: center;">50</td>
<td style="text-align: center;">55</td>
<td style="text-align: center;">60</td>
</tr>
<tr>
<td>8 m &lt; <em>h</em><sub>kv</sub>&nbsp;≤ 16 m</td>
<td style="text-align: center;">50</td>
<td style="text-align: center;">55</td>
<td style="text-align: center;">60</td>
<td style="text-align: center;">65</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading has-text-align-left" id="5">5 VÝPOČET DOPORUČENÉ SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">(1) Pro individuální stanovení světlé výšky místností včetně navýšení na případně odchylky geometrické přesnosti pro provádění lze v rámci DÚR využít postup výpočtu, který je popsán níže včetně všech uvažovaných proměnných, které by měly být ve výpočtu uvažovány.</p>



<p class="wp-block-paragraph">(2) Požadavky na minimální světlé výšky jsou uvedeny v&nbsp;<a href="#P-1.1">příloze č. 1.1</a>.</p>



<p class="wp-block-paragraph">(3)&nbsp;<strong>Doporučená světlá výška</strong>&nbsp;(<em>h</em><sub>sv,dop</sub>) se vypočte podle následujícího vztahu:</p>



<div class="wp-block-columns are-vertically-aligned-top is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:66.66%">
<p class="has-text-align-left is-style-vzorec-svisla-cara wp-block-paragraph"><em>h</em><sub>sv,dop</sub>&nbsp;= <em>h</em><sub>norm</sub>&nbsp;+ (Δ<em>h</em><sub>kv</sub>&nbsp;+ Δ<em>t</em><sub>sd</sub>&nbsp;+ Δ<em>t</em><sub>p</sub>&nbsp;+ <em>t</em><sub>ps</sub>&nbsp;+ <em>p</em>) · <em>k</em><sub>0,95</sub></p>
</div>



<div class="wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:33.33%">
<p class="has-text-align-right wp-block-paragraph">(5.1)</p>
</div>
</div>



<p class="wp-block-paragraph">kde je</p>



<p class="wp-block-paragraph"><em>h</em><sub>norm</sub> &#8230; požadovaná minimální světlá výška (viz <a href="#P-1.1">příloha č. 1.1</a>);<br>Δ<em>h</em><sub>kv</sub> &#8230; odchylka konstrukční výšky (viz <a href="#6-1">kap. 6.1</a>);<br>Δ<em>t</em><sub>sd</sub> &#8230; odchylka tloušťky stropní desky (viz <a href="#6-1">kap. 6.1</a>);<br>Δ<em>t</em><sub>p</sub> &#8230; odchylka tloušťky podlahy (viz <a href="#6-2">kap. 6.2</a>);<br><em>t</em><sub>ps</sub> &#8230; tloušťka povrchové úpravy spodního líce stropní desky (viz <a href="#6-3">kap. 6.3</a> a <a href="#6-4">6.4</a>);<br><em>p</em> &#8230; předpokládaný průhyb stropní konstrukce (viz <a href="#6-5">kap. 6.5</a>);<br><em>k</em><sub>0,95</sub> &#8230; koeficient pravděpodobnosti výskytu maximálních odchylek.<br>Odchylky jsou uvažovány v kladných hodnotách.</p>



<p class="wp-block-paragraph">(4) V rámci výpočtu je uvažováno s maximálními možnými odchylkami. Ve skutečnosti nelze předpokládat, že by se maximální odchylky vyskytly všechny najednou. V rámci výpočtu je proto zaveden koeficient k<sub>0,95</sub>, jehož doporučená hodnota je 0,71. Tato hodnota odpovídá zhruba 95% kvantilu a byla stanovena experimentálně na základě skutečně změřených hodnot.</p>


<div class="wp-block-image">
<figure class="aligncenter size-large"><img decoding="async" width="590" height="227" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts01_5_1.gif" alt="" class="wp-image-1001"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 5.1</em>&nbsp;&nbsp;95% kvantil náhodné veličiny s normálním rozdělením</p>



<p class="wp-block-paragraph">(5) U konstrukce s podhledem není nutné započítávat povrchovou úpravu stropu.</p>



<p class="wp-block-paragraph">(6) Pokud je povrchovou úpravou stropu podhled s volnou výškou, je možné z výše uvedeného vztahu vynechat předpokládaný průhyb stropu.</p>



<p class="wp-block-paragraph">(7) Přípustné mezní odchylky světlé výšky by měly být uvedeny ve výkresech jedním z následujících způsobů:</p>



<p class="wp-block-paragraph">a) stanovením mezních odchylek v rámci kótovaných rozměrů, např. 2&nbsp;650 (±35) nebo 2&nbsp;650 (+20; -50);<br>b) stanovením mezních odchylek v rámci poznámek k legendě výkresu.</p>



<p class="wp-block-paragraph">Při navrhované minimální světlé výšce stanovené předpisem nelze použít zápornou mezní odchylku.</p>



<p class="wp-block-paragraph">(8) Pokud nejsou v návrhu stavby uvedeny mezní odchylky světlé výšky, předpokládá se, že návrhová světlá výška je stanovena tak, aby skutečná světlá výška, která může být vyšší nebo nižší v souladu s odchylkami příslušných norem, nebyla nižší než požadovaná světlá výška podle platných předpisů. Výše uvedené odchylky se nepovažují za vadu.</p>



<p class="wp-block-paragraph">(9) Pro dodržení normových nebo právních požadavků na&nbsp;<strong>minimální světlou výšku</strong>&nbsp;musí být&nbsp;<strong>návrhová světlá výška</strong>&nbsp;stanovena&nbsp;následovně:</p>



<div class="wp-block-katex-display-block katex-eq" data-katex-display="true"><pre>\begin{gathered}
h_{sv,pd} \ge h_{sv,dop} &gt; h_{sv,norm}
\end{gathered}</pre></div>



<p class="has-text-align-right wp-block-paragraph">(5.2)</p>



<p class="wp-block-paragraph">kde je</p>



<p class="wp-block-paragraph"><em>h</em><sub>sv,pd</sub> &#8230; návrhová světlá výška;<br><em>h</em><sub>sv,dop</sub> &#8230; vypočtená doporučená minimální světlá výška;<br><em>h</em><sub>sv,norm</sub> &#8230; předepsaná minimální světlá výška (viz <a href="#P-1.1">příloha č. 1</a>.<a href="#10">1</a>).</p>



<p class="wp-block-paragraph"><strong>POZOR:</strong>&nbsp;Pokud bude v projektové dokumentaci navržena světlá výška shodná s minimálními požadavky technických norem nebo právních předpisů, velmi pravděpodobně dojde během realizace stavby vlivem přípustných tolerancí k jejímu snížení a tím k nedodržení minimálních požadavků.</p>



<p class="wp-block-paragraph">(10) Při podrobném návrhu nebo kontrole světlé výšky v rámci dokumentace pro provedení stavby lze využít výpočetní pomůcku, která je přílohou tohoto standardu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="6" class="wp-block-heading">6 DOPORUČENÉ HODNOTY PRO VÝPOČET SVĚTLÉ VÝŠKY</h3>



<h3 id="6-1" class="wp-block-heading">6.1 ODCHYLKY NOSNÉ KONSTRUKCE</h3>



<p class="wp-block-paragraph">(1) Výšku nosné konstrukce bez povrchových úprav může výrazně ovlivnit odchylka konstrukční výšky. K této odchylce je ještě potřeba připočíst odchylku tloušťky horní stropní desky. V případě, že horní líc desky je např. vybetonován v souladu s požadavky projektové dokumentace (dále PD), ale spodní líc desky je ve skutečnosti níž než navrhovaná výšková úroveň (např. vinou poklesu bednění při betonáži), může zvětšený průřez horní stropní desky negativně ovlivnit výšku hrubých konstrukcí.</p>



<p class="wp-block-paragraph">(2)&nbsp;<strong>Odchylka konstrukční výšky</strong>&nbsp;(Δ<em>h</em><sub>kv</sub>) &#8211; přípustná hodnota odchylky se stanoví podle typu nosné konstrukce, případně podle navrhované konstrukční výšky.</p>



<p class="wp-block-paragraph"><em>Tab. 6.1</em>&nbsp;&nbsp;Doporučené normové odchylky konstrukční výšky</p>



<table style="border-collapse: collapse; width: 100%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Betonové monolitické a prefabrikované konstrukce</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Ocelové konstrukce</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Zděné, dřevěné a ostatní konstrukce</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;" rowspan="3">Konstrukční výška</td>
<td style="vertical-align: middle; text-align: center;" rowspan="3">±20 mm</td>
<td style="vertical-align: middle; text-align: center;" rowspan="3">
<p>Třída 1: ±10 mm<br>Třída 2: ±5 mm</p>
</td>
<td style="text-align: center;">±25 mm pro <em>h</em> ≤ 4 m</td>
</tr>
<tr>
<td style="text-align: center;">±30 mm pro 4 m &lt; <em>h</em> ≤ 8 m</td>
</tr>
<tr>
<td style="text-align: center;">±40 mm pro 8 m &lt; <em>h</em> ≤ 16 m</td>
</tr>
<tr>
<td style="vertical-align: middle;">Norma</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=86077&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 13670</a>, obr. G.3e</td>
<td style="text-align: center;"><a href="https://csnonline.agentura-cas.cz/Detailnormy.aspx?k=519940" target="_blank" rel="noopener">ČSN EN&nbsp;1090-2+A1</a>, B.15-2</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 0205</a> tab. A.1</td>
</tr>
<tr>
<td colspan="4"><em>h</em> je konstrukční výška.</td>
</tr>
<tr>
<td colspan="4">U ocelových konstrukcí jsou hodnoty odchylek uvedeny pro dvě toleranční třídy. Zvolená toleranční třída musí být specifikována v prováděcí dokumentaci. Pokud v dokumentaci není uvedena toleranční třída, je závazná toleranční třída 1.</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">(3) U konstrukcí, kde není požadavek na odchylku konstrukční výšky v prováděcí normě definován, musí přípustnou odchylku konstrukční výšky stanovit projektant v rámci návrhu světlé výšky. Jako podklad lze využít přílohu A, tab. A.1 normy pro navrhování geometrické přesnosti&nbsp;ČSN 73 0205&nbsp;tak, aby vznikla dostatečná rezerva výšky.</p>



<p class="wp-block-paragraph">(4)&nbsp;<strong>Odchylka tloušťky stropní desky</strong>&nbsp;(Δ<em>t</em><sub>sd</sub>) &#8211; přípustná hodnota odchylky se stanoví podle typu konstrukce a tloušťky stropní desky.</p>



<p class="wp-block-paragraph"><em>Tab. 6.2</em>&nbsp;&nbsp;Doporučené normové odchylky tloušťky stropní konstrukce</p>



<table style="border-collapse: collapse; width: 100%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Betonové monolitické a prefabrikované konstrukce</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Ocelové konstrukce</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Zděné, dřevěné a ostatní konstrukce</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;" rowspan="3">Tloušťka stropní konstrukce</td>
<td style="text-align: center;">±10 mm pro <em>t</em> ≤ 150 mm</td>
<td style="vertical-align: middle; text-align: center;" rowspan="3">Třída 1: ±10 mm
<p>Třída 2: ±5 mm</p>
</td>
<td style="vertical-align: middle; text-align: center;" rowspan="3">Není stanoveno normami,
<p>doporučená hodnota ±10 mm</p>
</td>
</tr>
<tr>
<td style="text-align: center;">±15 mm pro <em>t</em> = 400 mm<br>pro monolit, deskové dílce;</td>
</tr>
<tr>
<td style="text-align: center;">±15 mm pro <em>t</em> = 250 mm<br>pro dutinové panely</td>
</tr>
<tr>
<td style="vertical-align: middle;">Norma</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=86077&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 13670</a> obr. 4a,<br><a href="https://csnonline.agentura-cas.cz/Detailnormy.aspx?k=90588" target="_blank" rel="noopener">ČSN EN 1168+A3</a>,&nbsp;čl. 4.3.1.1.1a</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://csnonline.agentura-cas.cz/Detailnormy.aspx?k=519940" target="_blank" rel="noopener">ČSN EN&nbsp;1090-2+A1</a>, B.15-6</td>
<td style="text-align: center;">&nbsp;</td>
</tr>
<tr>
<td colspan="4"><em>t</em> je tloušťka konstrukce; pro betonové konstrukce lze mezilehlé hodnoty interpolovat.</td>
</tr>
<tr>
<td colspan="4">U ocelových konstrukcí se bere v úvahu výšková odchylka úrovně horního líce sousedních stropních nosníků.</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(5) U konstrukcí, kde není požadavek na odchylku tloušťky stropní desky v prováděcí normě definován, musí přípustnou odchylku tloušťky stropní desky stanovit projektant v rámci návrhu světlé výšky.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="6-2" class="wp-block-heading">6.2 ODCHYLKA TLOUŠŤKY PODLAHY (Δ<em>t</em><sub>p</sub>)</h3>



<p class="wp-block-paragraph">(1) Odchylku tloušťky podlahy může výrazně ovlivnit odchylka tloušťky roznášecí vrstvy podlahy a také tloušťka vyrovnávací vrstvy mezi hrubou podlahou na nášlapnou vrstvou.</p>



<p class="wp-block-paragraph">(2) V rámci výpočtu doporučené světlé výšky lze uvažovat odchylky podlahy (Δ<em>t</em><sub>p</sub>) uvedené v tab. 6.3.</p>



<p class="wp-block-paragraph"><em>Tab. 6.3</em>&nbsp;&nbsp;Doporučené odchylky tloušťky podlahy</p>



<table style="border-collapse: collapse; width: 100%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Podlaha v občanských a bytových stavbách</strong></td>
<td style="text-align: center;"><strong data-rich-text-format-boundary="true">Průmyslová podlaha</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;" rowspan="2">Tloušťka podlahy</td>
<td style="text-align: center;">17 mm pro <em>t</em><sub>p</sub>&nbsp;≤ 150 mm</td>
<td style="vertical-align: middle; text-align: center;" rowspan="2">0,2 . <em>t</em><sub>p</sub>&nbsp;(v mm)</td>
</tr>
<tr>
<td style="text-align: center;">0,125 . <em>t</em><sub>p</sub>&nbsp;(v mm) pro <em>t</em><sub>p</sub>&nbsp;&gt; 150 mm</td>
</tr>
<tr>
<td colspan="3"><em>t</em><sub>p</sub>&nbsp;je celková tloušťka podlahy.</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<h3 id="6-3" class="wp-block-heading">6.3 POVRCHOVÁ ÚPRAVA SPODNÍHO LÍCE STROPU (<em>t</em><sub>ps</sub>)</h3>



<p class="wp-block-paragraph">(1) Povrchová úprava stropů se v projektové dokumentaci zpravidla nekótuje. Pokud je navržena povrchová úprava formou omítky, musí být v rámci navrhované světlé výšky uvažováno s rezervou, která pokryje tloušťku navržené povrchové úpravy.</p>



<p class="wp-block-paragraph">(2) V rámci výpočtu doporučené minimální světlé výšky lze uvažovat následující dva základní typy úpravy spodního líce stropní konstrukce:</p>



<p class="wp-block-paragraph">a)&nbsp;<strong>Kontaktní povrchová úprava stropu</strong>&nbsp;(např. omítka nebo stěrka) – v rámci výpočtu je třeba počítat s tloušťkou povrchové úpravy (<em>t</em><sub>ps</sub>&nbsp;= navrhovaná tloušťka povrchové úpravy);</p>



<p class="wp-block-paragraph">b)&nbsp;<strong>Pohledový beton</strong>&nbsp;– tuto variantu lze zvolit v případě, že spodní líc stropní konstrukce nebude mít žádnou následnou povrchovou úpravu (<em>t</em><sub>ps</sub>&nbsp;= 0).</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="6-4" class="wp-block-heading">6.4 PODHLED (<em>t</em><sub>ps</sub>)</h3>



<p class="wp-block-paragraph">(1) Výška spodního líce podhledu musí být navržena tak, aby byly dodrženy předepsané minimální technické nebo normové požadavky na světlé výšky i po započtení rezervy na provedení nosných konstrukcí a povrchových úprav podlahy.</p>



<p class="wp-block-paragraph">(2) Při vedení rozvodů TZB (kanalizace, VZT, silnoproud, datové kabely atd.) v části podhledu je potřeba navrhnout výšku (tloušťku) podhledu tak, aby byla započítána potřebná výška pro rozvody potrubí včetně jeho izolací (s respektováním minimálních spádů a křížení potrubí). Je třeba nezapomenout také na rezervu výšky potřebnou pro instalaci rozvodů nebo světel do podhledu.</p>



<p class="wp-block-paragraph">(3) V rámci výpočtu doporučené světlé výšky uvažovat odchylku osazení výšky podhledu ±10 mm. Odchylku lze uvést v rámci povrchové úpravy stropu (<em>t</em><sub>ps</sub>&nbsp;= 10 mm).</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="6-5" class="wp-block-heading">6.5 PRŮHYB STROPNÍ KONSTRUKCE (<em>p</em>)</h3>



<p class="wp-block-paragraph">(1) Předpokládaný průhyb stropní konstrukce by měl být stanoven výpočtem v příslušné části projektové dokumentace. Pokud průhyb není stanoven, měl by být v rámci výpočtu doporučené minimální světlé výšky určen odhadem nebo jako limitní, podle druhu stropní konstrukce. Pro beton a ocel je uvažována limitní hodnota l/250 rozpětí mezi podpěrami.</p>



<p class="wp-block-paragraph">(2) Nadvýšení předpjatých panelů se zanedbává.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="7" class="wp-block-heading">7 VYUŽITÍ POMŮCKY PRO STANOVENÍ NÁVRHOVÉ SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">(1) Přílohou k tomuto technickému standardu je výpočetní pomůcka naprogramovaná v prostředí MS Excel, která slouží jako</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>pomůcka pro projektanty ke správnému návrhu (list „Návrh světlé výšky”)</li>



<li>pomůcka pro zhotovitele k posouzení PD (list „Posouzení světlé výšky”)</li>
</ul>



<p class="wp-block-paragraph">Výpočetní pomůcka slouží ke stanovení doporučeného navrhovaného nadvýšení tak, aby po realizaci stavby byl splněn požadavek na minimální světlou výšku nebo ke kontrole zhotovené PD, zdali je nadvýšení dostatečné. Postup, jak pracovat s pomůckou, je uveden vpravo na každém z výpočetních listů.</p>



<p class="wp-block-paragraph">(2) Tvůrce výpočetní pomůcky odpovídá za její funkčnost a soulad s tímto standardem, neodpovídá však za zadané údaje a z nich vyplývající výsledek ve vztahu k navrhovanému projektu a posuzované stavbě.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="8" class="wp-block-heading">8 MĚŘENÍ SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">(1) Výšky místností se kontrolují ve vzdálenosti 100 mm od stěn, sloupů, uprostřed délky a šířky místností. Výšky průvlaků a podobných konstrukcí se kontrolují 100 mm od líce podpůrné konstrukce (stěny nebo čel úložných konzol), popř. ještě uprostřed půdorysného rozměru.</p>


<div class="wp-block-image">
<figure class="aligncenter size-large"><img decoding="async" width="457" height="273" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts01_8_1.gif" alt="" class="wp-image-1002"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 8.1</em>&nbsp;&nbsp;Měření svislých rozměrů místností (světlá výška)</p>



<p class="wp-block-paragraph">(2) Výška místnosti s trámovým stropem se kontroluje v ose trámu, ve vzdálenosti 100 mm od svislých podpor (stěny, sloupy) a uprostřed rozpětí trámu.</p>


<div class="wp-block-image">
<figure class="aligncenter size-large"><img loading="lazy" decoding="async" width="484" height="257" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts01_8_2.gif" alt="" class="wp-image-1003"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 8.2</em>&nbsp;&nbsp;Měření světlé výšky místnosti s trámovým stropem</p>



<p class="wp-block-paragraph">(3) Odsazení měření zhruba 100 mm od hran svislých podpor (stěn, sloupů) je doporučeno z důvodů výskytu možných větších nerovností povrchové úpravy na hranách konstrukce. Požadavky na jiná místa měření musí být uvedeny v dokumentaci.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>Odsazení o 100 mm umožňuje vyloučit vliv nepodstatných nerovností stropu nebo podlahy u podpěr.</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="9" class="wp-block-heading">9 LITERATURA, CITOVANÉ NORMY A PŘEDPISY</h3>



<p class="wp-block-paragraph">[1]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=70325&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73 4301</a>&nbsp;Obytné budovy, ČNI, Praha 2004.</p>



<p class="wp-block-paragraph">[2]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=72329&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73 5305</a>&nbsp;Administrativní budovy a prostory, ČNI, Praha 2005.</p>



<p class="wp-block-paragraph">[3]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=15183&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73 5105</a>&nbsp;Výrobní průmyslové budovy, ČNI, Praha 1994.</p>



<p class="wp-block-paragraph">[4]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=88898&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73 6058</a>&nbsp;Jednotlivé, řadové a hromadné garáže, ÚNMZ, Praha 2011.</p>



<p class="wp-block-paragraph">[5]&nbsp;<a href="https://csnonline.agentura-cas.cz/DetailNormy.aspx?k=85172" target="_blank" rel="noreferrer noopener nofollow">ČSN 73 4130</a> Schodiště a šikmé rampy – Základní požadavky, ÚNMZ, Praha 2010</p>



<p class="wp-block-paragraph">[6] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17347&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73&nbsp;0202</a>&nbsp;Geometrická přesnost ve výstavbě. Základní ustanovení, ČNI, Praha 1995.</p>



<p class="wp-block-paragraph">[7] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73&nbsp;0205</a>&nbsp;Geometrická přesnost ve výstavbě. Navrhování geometrické přesnosti, ČNI, Praha 1995.</p>



<p class="wp-block-paragraph">[8] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=20601&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73&nbsp;0212-3</a>&nbsp;Geometrická přesnost ve výstavbě. Kontrola přesnosti. Část 3: Pozemní stavební objekty, ČNI, Praha 1997.</p>



<p class="wp-block-paragraph">[9] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=86077&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN EN&nbsp;13670</a>&nbsp;Provádění betonových konstrukcí, ÚNMZ, Praha 2010.</p>



<p class="wp-block-paragraph">[10] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90588&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN EN&nbsp;1168+A3</a>&nbsp;Betonové prefabrikáty –&nbsp;Dutinové panely, ÚNMZ, Praha 2012.</p>



<p class="wp-block-paragraph">[11] <a href="https://csnonline.agentura-cas.cz/Detailnormy.aspx?k=77706" target="_blank" rel="noreferrer noopener nofollow">ČSN EN 1996-2</a> Eurokód 6: Navrhování zděných konstrukcí –&nbsp;Část 2: Volba materiálů, konstruování a&nbsp;provádění zdiva, Česká agentura pro standardizaci, Praha 2007.</p>



<p class="wp-block-paragraph">[12] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=32694&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 73&nbsp;2810</a>&nbsp;Dřevěné stavební konstrukce –&nbsp;Provádění, FÚNM, Praha 1993.</p>



<p class="wp-block-paragraph">[13] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=95221&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN EN&nbsp;336</a>&nbsp;Konstrukční dřevo –&nbsp;Rozměry, dovolené odchylky, ÚNMZ, Praha 2014.</p>



<p class="wp-block-paragraph">[14] <a href="https://csnonline.agentura-cas.cz/Detailnormy.aspx?k=519940" target="_blank" rel="noreferrer noopener nofollow">ČSN EN 1090-2+A1</a>&nbsp;Provádění ocelových konstrukcí a&nbsp;hliníkových konstrukcí –&nbsp;Část 2: Technické požadavky na ocelové konstrukce, Česká agentura pro standardizaci, Praha 2024.</p>



<p class="wp-block-paragraph">[15] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=89997&amp;cid=5" target="_blank" rel="noreferrer noopener nofollow">ČSN 74&nbsp;4505</a>&nbsp;Podlahy –&nbsp;Společná ustanovení, Česká agentura pro standardizaci, Praha 2025.</p>



<p class="wp-block-paragraph">[16] Vyhláška MMR <a href="https://e-sbirka.gov.cz/sb/2024/146?zalozka=text" target="_blank" rel="noreferrer noopener nofollow">č. 146/2024 Sb.</a>, o požadavcích na výstavbu, ve znění pozdějších předpisů</p>



<p class="wp-block-paragraph">[17] Vyhláška MMR&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noreferrer noopener nofollow">č. 268/2009 Sb.</a>, o&nbsp;technických požadavcích na stavby.</p>



<p class="wp-block-paragraph">[18] Nařízení&nbsp;<a href="https://sbirkapp.gov.cz/detail/SPPWYQ6L6EMQU2XO" target="_blank" rel="noreferrer noopener nofollow">č. 10/2016 Sb.&nbsp;hl. m.&nbsp;Prahy</a>, kterým se stanovují obecné požadavky na využívání území a&nbsp;technické požadavky na stavby v&nbsp;hlavním městě Praze (pražské stavební předpisy, platné do 30. 6. 2024).</p>



<p class="wp-block-paragraph">[19] Nařízení vlády&nbsp;<a href="https://e-sbirka.gov.cz/sb/2007/361?zalozka=text" target="_blank" rel="noreferrer noopener nofollow">č. 361/2007 Sb.</a>, kterým se stanoví podmínky ochrany zdraví při&nbsp;práci.</p>



<p class="wp-block-paragraph">[20] Nařízení hlavního města Prahy <a href="https://sbirkapp.gov.cz/vyhledavani/vysledek?hlavni_typ=pp&amp;typ=narizeni&amp;ovm=&amp;kod_vusc=19&amp;nazev=Na%C5%99%C3%ADzen%C3%AD+hlavn%C3%ADho+m%C4%9Bsta+Prahy+o+po%C5%BEadavc%C3%ADch+na+v%C3%BDstavbu&amp;number=&amp;vydano_od=&amp;vydano_do=&amp;zverejneno_od=&amp;zverejneno_do=&amp;ucinnost_od=&amp;ucinnost_do=&amp;platnost=" target="_blank" rel="noreferrer noopener nofollow">č. 12/2024,</a> o požadavcích na výstavbu v&nbsp;hl. m. Praze (pražské stavební předpisy, platné od 1. 7. 2024)</p>



<p class="wp-block-paragraph">[21] Nařízení <a href="https://sbirkapp.gov.cz/detail/SPPFAUNEEHOB4WDO" target="_blank" rel="noreferrer noopener nofollow">č. 14/2024</a>, o požadavcích na výstavbu ve statutárním městě Brně (brněnské stavební předpisy, platné od 1. 7. 2024)</p>



<p class="wp-block-paragraph"><br></p>



<h3 id="Příloha-1" class="wp-block-heading">PŘÍLOHA 1 – VÝBĚR POŽADOVANÝCH SVĚTLÝCH VÝŠEK PODLE PŘEDPISŮ</h3>



<p class="wp-block-paragraph">Níže uvedené hodnoty požadovaných světlých výšek vyplývajících z předpisů jsou minimální. Návrhová hodnota světlé výšky v konkrétní stavbě pro daný účel splnit všechny základní požadavky na stavby, především požadavek na ochranu zdraví. Například dle čl. 5.2.2.11 normy ČSN 73 4301 má být objem místnosti pro spaní 1&nbsp;osoby nejméně 20 m<sup>3</sup>, objem místnosti pro spaní 2 osob nejméně 30 m<sup>3</sup> apod. Z toho vyplývá, že u minimálních rozměrů místností (8 m<sup>2</sup>, potažmo 12 m<sup>2</sup>), nesmí být světlá výška lokálně snížena při limitním návrhu.</p>



<h3 id="P-1.1" class="wp-block-heading">P 1.1 Bytové domy, rodinné domy a&nbsp;jejich nástavby či&nbsp;přístavby</h3>



<figure class="wp-block-table"></figure>



<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td rowspan="2"><strong>Prostor</strong></td>
<td style="text-align: center;" colspan="8"><strong>Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><a href="https://csnonline.agentura-cas.cz/DetailNormy.aspx?k=70325" target="_blank" rel="noopener">ČSN 73 4301</a><br>(platná do 30. 6. 2026)</td>
<td style="text-align: center;" colspan="2"><a href="https://csnonline.agentura-cas.cz/DetailNormy.aspx?k=523811" target="_blank" rel="noopener">ČSN 73 4301</a><br>(platná od 1.&nbsp;7. 2026)</td>
<td style="text-align: center;" colspan="2">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener">č.268/2009 Sb.</a>&nbsp;(platná do 30. 6. 2024)</td>
<td style="text-align: center;" colspan="2">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2024/146?zalozka=text" target="_blank" rel="noopener">č. 146/2024 Sb.</a><br>(platná od 1.&nbsp;7. 2024)</td>
</tr>
<tr>
<td><strong>Světlá výška obytné a pobytové místnosti</strong> bytových domů</td>
<td style="text-align: center;">
<p>2 600 <span style="font-family: inherit; font-size: 1em; font-weight: inherit;">mm</span></p>
</td>
<td style="text-align: center;">čl.5.2.2.9</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">
<p>2&nbsp;600 <span style="font-family: inherit; font-size: 1em; font-weight: inherit;">mm</span><sup style="font-family: inherit; font-weight: inherit;">1)</sup></p>
</td>
<td style="text-align: center;">§10 odst. 5</td>
<td style="text-align: center;">2&nbsp;500 mm<sup>2)</sup></td>
<td style="text-align: center;">§38 odst. 1</td>
</tr>
<tr>
<td><strong>Světlá výška obytné a pobytové místnosti</strong> rodinných domů a domů pro rodinnou rekreaci</td>
<td style="text-align: center;">2 500 mm</td>
<td style="text-align: center;">čl.5.2.2.9</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">2 500 mm<sup>1)</sup></td>
<td style="text-align: center;">§40 odst. 2</td>
<td style="text-align: center;">2 500 mm<sup>2)</sup></td>
<td style="text-align: center;">§38 odst. 1</td>
</tr>
<tr>
<td><strong>Světlá výška obytné a pobytové místnosti</strong> rodinných domů a domů pro rodinnou rekreaci v podkroví<sup>3)</sup></td>
<td style="text-align: center;">2 300 mm</td>
<td style="text-align: center;">čl.5.2.2.10</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">2 300 mm</td>
<td style="text-align: center;">§40 odst. 2</td>
<td style="text-align: center;">2&nbsp;200 mm</td>
<td style="text-align: center;">§38, odst. 1</td>
</tr>
<tr>
<td><strong>Podchodná výška</strong> hlavních <strong>schodišť a chodeb </strong>rodinných domů a domů pro rodinnou rekreaci</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">2 100 mm</td>
<td style="text-align: center;">§40 odst. 3</td>
<td style="text-align: center;" colspan="2">NPD<sup>4)</sup></td>
</tr>
<tr>
<td><strong>Podchodná</strong> výška<strong> vstupního prostoru bytu</strong></td>
<td style="text-align: center;">2&nbsp;100 mm</td>
<td style="text-align: center;">čl. 5.2.3.4</td>
<td style="text-align: center;">
<p>2&nbsp;100 <span style="font-family: inherit; font-size: 1em; font-weight: inherit;">mm</span></p>
</td>
<td style="text-align: center;">čl. 8.5.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Podchodná výška </strong>dalších <strong>prostor bytu</strong></td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">
<p>2&nbsp;100 <span style="font-family: inherit; font-size: 1em; font-weight: inherit;">mm</span></p>
</td>
<td style="text-align: center;">čl. 8.6.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Světlá výška</strong> prostoru<strong> pro vařen</strong>í</td>
<td style="text-align: center;">&nbsp;=výšce obytné/pobytové místnosti</td>
<td style="text-align: center;">čl. 5.2.3.8</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Světlá výška</strong> prostoru<strong> pro osobní hygienu</strong>, prostoru pro<strong> umístění záchodové mísy</strong></td>
<td style="text-align: center;">=výšce&nbsp;obytné/ pobytové místnosti, ≥2&nbsp;300 mm</td>
<td style="text-align: center;">čl. 5.2.3.15</td>
<td style="text-align: center;">2&nbsp;200 mm</td>
<td style="text-align: center;">čl. 8.4.3</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Podchodná</strong> výška domovní<strong> komunikace</strong></td>
<td style="text-align: center;">2 100 mm</td>
<td style="text-align: center;">čl. 5.3.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Světlá výška</strong> místnosti pro ukládání odpadků a společné místnosti (sklad, úklidová komora, sušárna apod.),</td>
<td style="text-align: center;">2 500 mm</td>
<td style="text-align: center;">čl.&nbsp;5.4.2.2</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Světlá výška</strong> ostatních místností a prostorů <strong>domovního vybavení</strong></td>
<td style="text-align: center;">2 500 mm</td>
<td style="text-align: center;">čl.&nbsp;5.4.2.2</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong>Podchodná</strong> výška <strong>ostatních místností a prostor domovního vybavení</strong></td>
<td style="text-align: center;">2&nbsp;100 mm</td>
<td style="text-align: center;">čl.&nbsp;5.4.2.2</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Světlá výška místností a prostorů <strong>domovního vybavení rodinných domů</strong></td>
<td style="text-align: center;">2 100&nbsp;mm</td>
<td style="text-align: center;">čl.&nbsp;5.4.2.4</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Sušárny, prádelny a žehlírny rodinných domů</td>
<td style="text-align: center;">2&nbsp;300 mm</td>
<td style="text-align: center;">čl.&nbsp;5.4.2.4</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td colspan="9"><sup>1)</sup> <strong>V Praze </strong>lze minimální světlou výšku <strong>obytné místnosti</strong> snížit na 2,4 m, pokud je součástí bytu <strong>alespoň jedna obytná místnost</strong> o výšce min. 2,6 m a ploše větší než 16 m<sup>2</sup> (§44,&nbsp;odst.&nbsp;1). U <strong>staveb pro rodinnou rekreaci v Praze</strong> může být světlá výška <strong>pobytových místností</strong> snížena na 2,4 m. (Pražské stavební předpisy platné do 30. 6. 2024, §44)</td>
</tr>
<tr>
<td colspan="9"><sup>2)</sup> <strong>V Praze</strong> je možné snížit světlou výšku <strong>obytné místnosti nebo pobytové místnosti</strong> stavby pro bydlení na 2,4 m, pokud je v bytě <strong>alespoň jedna obytná místnost s obytným prostorem</strong> o světlé výšce 2,5 m (Pražské stavební předpisy platné od 1. 7. 2024, §42). <strong>V Brně</strong> musí být světlá výška <strong>obytné místnosti</strong> nebo<strong> pobytové místnost</strong>i stavby pro bydlení minimálně 2,6 m, ale je možné ji snížit na 2,4 m, pokud je v bytě alespoň jedna obytná místnost s obytným prostorem o světlé výšce alespoň 2,6 m (Brněnské stavební předpisy platné od 1. 7. 2024, §42). <strong>Světlá výška může být snížena</strong> až na 2,2 m, <strong>nejvýše nad polovinou podlahové plochy</strong> obytné místnosti (vyhláška č. 146/2024 Sb.). Požadavky na minimální světlou výšku se <strong style="font-size: revert; font-family: inherit;">netýkají staveb pro rodinnou rekreaci</strong><span style="font-size: revert; font-family: inherit; font-weight: inherit;">.</span></td>
</tr>
<tr>
<td colspan="9"><sup>3)</sup> V <strong>obytné místnosti se šikmým stropem</strong> musí být nejmenší světlá výška dosažena <strong>minimálně nad polovinou podlahové plochy</strong> prostoru. U prostorů se šikmými stropy se do <strong>plochy obytné místnosti nezapočítává</strong> plocha se světlou výškou menší než 1,2 m (podle vyhlášky č. 268/2009 Sb., vyhlášky č. 146/2024 Sb.), resp. 1300 mm (podle ČSN 73 4301 platné do 30. 6. 2026).</td>
</tr>
<tr>
<td colspan="9"><sup>4)</sup> <strong>Podchodná výška schodiště</strong> není od 1. 7. 2024 řešena vyhláškou 146/2024 Sb., ale požadavek na minimální podchodnou výšku 2&nbsp;100 mm je předepsán v&nbsp;ČSN 73 4130, čl. 6.7.4 pro hlavní schodiště v&nbsp;rodinných domech, schodiště uvnitř bytů, schodiště v&nbsp;objektech pro rodinnou rekreaci a pro pomocná schodiště.</td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading">P 1.2 Jednotlivé, řadové a&nbsp;hromadné garáže</h3>



<table style="border-collapse: collapse; width: 100%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td style="width: 46.6783%;" rowspan="2">
<p><strong>Prostor</strong> pro vozidla skupiny 1 (osobní vozidla a lehká užitková vozidla – dodávky) s pohybem vozidel vlastní silou</p>
</td>
<td style="width: 53.3217%; text-align: center;" colspan="4">
<p><strong>Předpis</strong></p>
</td>
</tr>
<tr>
<td style="width: 26.5734%; text-align: center;" colspan="2">
<p>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener">č. 268/2009 Sb</a>. (platná do 30. 6. 2024) a ČSN 73 6058</p>
</td>
<td style="width: 26.7483%; text-align: center;" colspan="2">
<p>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2024/146?zalozka=text" target="_blank" rel="noopener">č. 146/2024 Sb.</a> (platná od 1. 7. 2024)</p>
</td>
</tr>
<tr>
<td style="width: 46.6783%;">
<p><strong>Volná (podjezdná) výška <em>h</em></strong> v prostoru garáže</p>
</td>
<td style="width: 13.986%; text-align: center;">
<p>2 200 mm<sup>1)</sup></p>
</td>
<td style="width: 12.5874%; text-align: center;">
<p>§47 a čl. 5.1.3</p>
</td>
<td style="width: 13.8112%; text-align: center;">
<p>2 200 mm<sup>2)</sup></p>
</td>
<td style="width: 12.9371%; text-align: center;">
<p>§38, odst. 3</p>
</td>
</tr>
<tr>
<td style="width: 46.6783%;">
<p><strong>Volná (podjezdná) výška <em>h</em></strong> v&nbsp;místě zavazadlového prostoru vozidla</p>
</td>
<td style="width: 13.986%; text-align: center;">
<p>2&nbsp;400 mm</p>
</td>
<td style="width: 12.5874%; text-align: center;">
<p>§47 a čl. 5.1.4</p>
</td>
<td style="width: 26.7483%; text-align: center;" colspan="2">
<p>NPD</p>
</td>
</tr>
<tr>
<td style="width: 46.6783%;">
<p><strong>Volná výška</strong> v místech <strong>přechodu mezi rampami</strong> s různým podélným sklonem nebo nad rampami s podélným sklonem ≥ 8 %</p>
</td>
<td style="width: 13.986%; text-align: center;">
<p>2 300 mm</p>
</td>
<td style="width: 12.5874%; text-align: center;">
<p>§47 a čl. 5.1.5</p>
</td>
<td style="width: 13.8112%; text-align: center;">
<p>2 300 mm</p>
</td>
<td style="width: 12.9371%; text-align: center;">
<p>§38, odst. 3</p>
</td>
</tr>
<tr>
<td style="width: 100%;" colspan="5">
<p>Výška <strong>průjezdního profilu</strong> (volná výška <em>h</em>) <strong>musí být</strong> zachována v místě všech <strong>zařízení v garáži</strong>, kde je umožněn <strong>pohyb</strong> nebo <strong>parkování</strong> vozidel.</p>
</td>
</tr>
<tr>
<td style="width: 100%;" colspan="5">
<p>Volná výška h v prostoru garáže se navrhuje nejméně o 200&nbsp;mm větší, než je výška nejvyššího projektem předpokládaného vozidla, minimálně 2&nbsp;200 mm.</p>
</td>
</tr>
<tr>
<td style="width: 100%;" colspan="5">
<p><sup>1)</sup> <strong>V Praze</strong> lze v prostoru garáží <strong>snížit podchodnou výšku</strong> na 1,8 m do hloubky 0,7 m <strong>podél zadní stěny</strong> vázaných kolmých nebo vázaných šikmých stání. Za podchodnou výšku se považuje volná výška vnitřního prostoru stavby mezi jeho podlahou a stropem, do které nezasahují žádné části ani vybavení stavby. (Pražské stavební předpisy platné do 31.&nbsp;12.&nbsp;2023, §57, odst.1)</p>
</td>
</tr>
<tr>
<td style="width: 100%;" colspan="5">
<p><sup>2) </sup><strong>V&nbsp;Praze a Brně</strong> lze v prostoru garáží <strong>snížit podchodnou výšku</strong> na 1,8 m do hloubky 0,7 m <strong>podél zadní stěny</strong> vázaných kolmých nebo vázaných šikmých stání. Za podchodnou výšku se považuje volná výška vnitřního prostoru stavby mezi jeho podlahou a stropem, do které nezasahují žádné části ani vybavení stavby. (Pražské stavební předpisy 2024, Brněnské stavební předpisy platné od 1. 7. 2024, §43, odst. 2)</p>
</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading">P 1.3 Výrobní průmyslové budovy</h3>



<table style="border-collapse: collapse; width: 99.1752%;" border="1" cellpadding="5px">
<tbody>
<tr>
<td style="vertical-align: middle; width: 63.8112%;" rowspan="2"><strong data-rich-text-format-boundary="true">Prostor</strong></td>
<td style="vertical-align: middle; text-align: center; width: 32.3566%;" colspan="4"><strong data-rich-text-format-boundary="true">Předpis</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center; width: 14%;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=15183&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 5105</a></td>
<td style="vertical-align: middle; text-align: center; width: 18.3566%;" colspan="2">NV&nbsp;<a href="https://e-sbirka.gov.cz/sb/2007/361?zalozka=text" target="_blank" rel="noopener noreferrer">č. 361/2007 Sb.</a><sup>2)</sup></td>
</tr>
<tr>
<td style="width: 63.8112%;"><strong data-rich-text-format-boundary="true">Světlá výška</strong>&nbsp;prostoru určeného pro&nbsp;<strong>trvalou práci</strong>&nbsp;při ploše</td>
<td style="vertical-align: middle; text-align: center; width: 14%;" colspan="2">&nbsp;</td>
<td style="vertical-align: middle; text-align: center; width: 18.3566%;" colspan="2">&nbsp;</td>
</tr>
<tr>
<td style="width: 63.8112%;">do 20 m<sup>2</sup></td>
<td style="vertical-align: middle; text-align: center; width: 14%;" colspan="2">NPD<sup>3)</sup></td>
<td style="vertical-align: middle; text-align: center; width: 9.44056%;">2 500 mm</td>
<td style="vertical-align: middle; text-align: center; width: 8.91608%;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst. 1</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p>do 50&nbsp;m<sup>2</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>2&nbsp;500 mm<sup>1)</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 5.1.2</p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>2&nbsp;600 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;1</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p>od 51 do 100&nbsp;m<sup>2</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>2&nbsp;700 mm<sup>1)</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 5.1.2</p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>2&nbsp;700 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;1</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p>od 101 do 2&nbsp;000&nbsp;m<sup>2</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>3&nbsp;000 mm<sup>1)</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 5.1.2</p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>3&nbsp;000 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;1</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p>více než 2&nbsp;000&nbsp;m<sup>2</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>3&nbsp;250 mm<sup>1)</sup></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 5.1.2</p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>3&nbsp;250 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;1</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p><strong>Světlá výška</strong>&nbsp;prostoru určeného pro práci se&nbsp;<strong>šikmým stropem</strong>&nbsp;při&nbsp;ploše do 20&nbsp;m<sup>2</sup></p>
</td>
<td style="width: 14%; text-align: center;" colspan="2" width="15%">
<p>NPD<sup>3)</sup></p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>2&nbsp;300 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;2</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p><strong>Světlá výška</strong>&nbsp;prostoru určeného pro práci, na kterém se vykonává práce&nbsp;<strong>výjimečně</strong>&nbsp;nebo po&nbsp;dobu kratší než 4 hodiny za&nbsp;směnu</p>
</td>
<td style="width: 14%; text-align: center;" colspan="2" width="15%">
<p>NPD<sup>3)</sup></p>
</td>
<td style="width: 9.44056%; text-align: center;" width="7%">
<p>2&nbsp;100 mm</p>
</td>
<td style="width: 8.91608%; text-align: center;" width="9%">
<p><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46">§&nbsp;46</a>, odst.&nbsp;2</p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p><strong>Světlá výška</strong>&nbsp;v&nbsp;provozech&nbsp;<strong>bez</strong>&nbsp;denního světla</p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>4&nbsp;500 mm</p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 5.1.3</p>
</td>
<td style="width: 18.3566%; text-align: center;" colspan="2" width="17%">
<p>NPD<sup>3)</sup></p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p><strong>Světlá výška</strong>&nbsp;komunikací pro&nbsp;<strong>dopravu břemen</strong></p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>2&nbsp;400 mm</p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 7.2.8 Z1</p>
</td>
<td style="width: 18.3566%; text-align: center;" colspan="2" width="17%">
<p>NPD<sup>3)</sup></p>
</td>
</tr>
<tr>
<td style="width: 63.8112%;" width="67%">
<p><strong>Světlá výška</strong>&nbsp;komunikací pro automobilový provoz</p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>3&nbsp;600 mm</p>
</td>
<td style="width: 7%; text-align: center;" width="7%">
<p>čl. 7.2.8 Z1</p>
</td>
<td style="width: 18.3566%; text-align: center;" colspan="2" width="17%">
<p>NPD<sup>3)</sup></p>
</td>
</tr>
<tr>
<td style="width: 96.1678%;" colspan="5">
<p><sup>1)</sup>&nbsp;Světlou výšku lze v&nbsp;odůvodněných případech snížit, v&nbsp;žádném případě nesmí být ale nižší než 2&nbsp;500 mm.</p>
</td>
</tr>
<tr>
<td style="width: 96.1678%;" colspan="5">
<p><sup>2)</sup>&nbsp;Světlé výšky uvedené v&nbsp;odstavci 1 písm. c) až d) mohou být v&nbsp;prodejním prostoru, kanceláři a&nbsp;v&nbsp;jiném obdobném prostoru určeném pro práci, v&nbsp;němž se vykonává práce zařazená do třídy I&nbsp;nebo IIa podle&nbsp;<a href="https://e-sbirka.gov.cz/sb/2007/361#prilohy" target="_blank" rel="noopener">přílohy č.&nbsp;1</a>&nbsp;k&nbsp;tomuto nařízení, části A, tabulky č.&nbsp;1 sníženy za předpokladu, že bude zajištěn pro každého zaměstnance objemový prostor podle&nbsp;<a href="https://e-sbirka.gov.cz/sb/2007/361#par_47" target="_blank" rel="noopener">§&nbsp;47</a>&nbsp;odst. 1 písm. a) nebo b), bude vyloučeno oslňování zaměstnance a&nbsp;světlá výška nebude nižší než 2,60&nbsp;m.</p>
</td>
</tr>
<tr>
<td style="width: 96.1678%;" colspan="5">
<p><sup>3)</sup>&nbsp;NPD –&nbsp;není požadováno</p>
</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading">P 1.4 Administrativní budovy a&nbsp;prostory</h3>



<table style="width: 100%; border-collapse: collapse;" border="1" cellpadding="5px">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong>Světlá výška</strong></td>
<td style="text-align: center; vertical-align: middle;" colspan="4"><strong>Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=72329&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 5305</a></td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NV č. <a href="https://e-sbirka.gov.cz/sb/2007/361?zalozka=text" target="_blank" rel="noopener noreferrer">361/2007 Sb.</a> <sup>1)</sup></td>
</tr>
<tr>
<td style="vertical-align: middle;"><strong>Světlá výška</strong> prostoru určeného pro <strong>trvalou práci</strong> při ploše</td>
<td style="text-align: center; vertical-align: middle;">&nbsp;</td>
<td style="text-align: center; vertical-align: middle;">&nbsp;</td>
<td style="text-align: center; vertical-align: middle;">&nbsp;</td>
<td style="text-align: center; vertical-align: middle;">&nbsp;</td>
</tr>
<tr>
<td>
<p>do 20 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;" rowspan="7">
<p>Minimální světlá výška kancelářských prostor 2 700 mm.</p>
<p>Doporučená světlá výška kancelářských prostor 3 000 mm.</p>
</td>
<td style="text-align: center; vertical-align: middle;" rowspan="7">čl. 5.2.4.1</td>
<td style="text-align: center; vertical-align: middle;">2&nbsp;500 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;1</td>
</tr>
<tr>
<td>
<p>do 50 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;">2&nbsp;600 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;1</td>
</tr>
<tr>
<td>
<p>od 51 do 100 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;">2&nbsp;700 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;1</td>
</tr>
<tr>
<td>
<p>od 101 do 2000 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;">3&nbsp;000 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;1</td>
</tr>
<tr>
<td>
<p>více než 2000 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;">3&nbsp;250 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;1</td>
</tr>
<tr>
<td>
<p><strong>Světlá výška</strong> prostoru určeného pro práci se <strong>šikmým stropem</strong> při ploše do 20 m<sup>2</sup></p>
</td>
<td style="text-align: center; vertical-align: middle;">2&nbsp;300 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;2</td>
</tr>
<tr>
<td>
<p><strong>Světlá výška</strong> prostoru určeného pro práci, na kterém se vykonává práce <strong>výjimečně</strong> nebo po dobu kratší než 4 hodiny za směnu</p>
</td>
<td style="text-align: center; vertical-align: middle;">2&nbsp;100 mm</td>
<td style="text-align: center; vertical-align: middle;"><a href="https://e-sbirka.gov.cz/sb/2007/361#par_46" target="_blank" rel="noopener noreferrer">§&nbsp;46</a>, odst.&nbsp;2</td>
</tr>
<tr>
<td>
<p><strong>Světlá výška</strong> komunikačních koridorů velkoprostorových, kombinovaných a flexibilních kanceláří a v buňkových kancelářích v jejich částech zpravidla navazujících na chodbový trakt, vždy mimo vlastní pracovní plochu.</p>
</td>
<td style="text-align: center; vertical-align: middle;">2 500 mm</td>
<td style="text-align: center; vertical-align: middle;">čl. 5.2.4.2</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td>
<p><strong>Světlá výška</strong> kancelářských pracovišť s vazbou na <strong>hotelové ubytování</strong> a na <strong>obytné prostory</strong> (domácí pracovny) v případě, že plocha kanceláře nepřesáhne 50 m<sup>2</sup> a je zaručena dostatečná výměna vzduchu a osvětlení.</p>
</td>
<td style="text-align: center; vertical-align: middle;">2 600 mm</td>
<td style="text-align: center; vertical-align: middle;">čl. 5.2.4.3</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td>
<p>Minimální <strong>světlá výška</strong><strong> jednacích a shromažďovacích </strong>prostor</p>
</td>
<td style="text-align: center; vertical-align: middle;">2 700 mm</td>
<td style="text-align: center; vertical-align: middle;">čl. 5.3.4</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td>
<p>Doporučená <strong>světlá výška</strong><strong> jednacích a shromažďovacích </strong>prostor</p>
</td>
<td style="text-align: center; vertical-align: middle;">3 000 mm</td>
<td style="text-align: center; vertical-align: middle;">čl. 5.3.4</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle; width: 49.4665%;" colspan="5"><sup>1)</sup> Světlé výšky uvedené v odstavci 1 písm. c) až d) mohou být v prodejním prostoru, kanceláři a v jiném obdobném prostoru určeném pro práci, v němž se vykonává práce zařazená do třídy I nebo IIa podle <a href="https://e-sbirka.gov.cz/sb/2007/361/2026-01-01#pril_1-cast_A" target="_blank" rel="noopener noreferrer" data-wplink-edit="true">přílohy č. 1</a> k tomuto nařízení, části A, tabulky č. 1 sníženy za předpokladu, že bude zajištěn pro každého zaměstnance objemový prostor podle <a href="https://e-sbirka.gov.cz/sb/2007/361#par_47" target="_blank" rel="noopener noreferrer">§ 47</a> odst. 1 písm. a) nebo b), bude vyloučeno oslňování zaměstnance a světlá výška nebude nižší než 2,60 m.</td>
</tr>
</tbody>
</table>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading">P 1.5 Ostatní stavby</h3>



<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td><strong>Prostor</strong></td>
<td style="text-align: center;" colspan="4"><strong>Předpis</strong></td>
</tr>
<tr>
<td><strong><em>Stavby ubytovacích zařízení</em></strong></td>
<td style="text-align: center;" colspan="2">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text">č. 268/2009 Sb</a>. (platná do 30. 6. 2024)</td>
<td style="text-align: center;" colspan="2">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2024/146?zalozka=text" target="_blank" rel="noopener">č. 146/2024 Sb.</a> (platná od 1. 7. 2024)</td>
</tr>
<tr>
<td>Světlá výška pokoje hosta</td>
<td style="text-align: center;">2 600 mm</td>
<td style="text-align: center;">§43 odst.4</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td><strong><em>Stavby škol, předškolních, školských a tělovýchovných zařízení</em></strong></td>
<td style="text-align: center;" colspan="2">Vyhláška č. 268/2009 Sb.</td>
<td style="text-align: center;" colspan="2">Vyhláška č. 146/2024 Sb. (platná od 1. 7. 2024)</td>
</tr>
<tr>
<td>Světlá výška pobytové místnosti mateřské školy a speciální mateřské školy<sup>1)</sup></td>
<td style="text-align: center;">3 000 mm</td>
<td style="text-align: center;" rowspan="5">§49 odst.1</td>
<td style="text-align: center;">2 500 mm</td>
<td style="text-align: center;">§38 odst.2</td>
</tr>
<tr>
<td>Světlá výška u základních, středních, vyšších a speciálních škol<sup>2)</sup></td>
<td style="text-align: center;">3 300 mm</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Světlá výška u tělocvičen rozměrů 12 m x 18 m a 12 m x 24 m</td>
<td style="text-align: center;">6 000 mm</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Světlá výška u tělocvičen rozměrů 18 m x 30 m a větších</td>
<td style="text-align: center;">7 000 mm</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Světlá výška u šaten</td>
<td style="text-align: center;">2 500 mm</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td colspan="5"><sup>1)</sup> Snížení na světlou výšku 2 500 mm lze připustit, pokud je dodržena kubatura vzduchu 12 m<sup>3</sup> na jedno dítě.</td>
</tr>
<tr>
<td colspan="5"><sup>2)</sup> Při dodržení všech podmínek denního osvětlení na pracovní plochy je možné snížení na světlou výšku 3 000 mm, pokud je dodržena kubatura vzduchu 5,3 m<sup>3</sup> na jednoho žáka.</td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph"><br></p>



<h3 id="Příloha-2" class="wp-block-heading">PŘÍLOHA 2 – POMOCNÝ VÝPOČET PRO STANOVENÍ NÁVRHOVÉ SVĚTLÉ VÝŠKY</h3>



<p class="wp-block-paragraph">Pomocný výpočet pro stanovení návrhové světlé výšky:</p>



<div class="wp-block-file alignright"><a id="wp-block-file--media-50c04ed4-6f09-4e28-94d7-267b2abb6061" href="https://profesis.ckait.cz/wp-content/uploads/2020/07/ts01-2026-7-priloha02.xlsx">Příloha 2</a><a href="https://profesis.ckait.cz/wp-content/uploads/2020/07/ts01-2026-7-priloha02.xlsx" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-50c04ed4-6f09-4e28-94d7-267b2abb6061">Stáhnout</a></div>



<p class="wp-block-paragraph"><strong><em>Upozornění:</em></strong><em>&nbsp;Tabulka (xlsx) není určena pro ANDROID a pro MAC OS.</em></p>



<p class="wp-block-paragraph"></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TS 02 &#8211; Geometrická přesnost schodišť a šikmých ramp (Technický standard ČKAIT)</title>
		<link>https://profesis.ckait.cz/dokumenty-ckait/ts-02/</link>
		
		<dc:creator><![CDATA[CKAIT Profesis Admin]]></dc:creator>
		<pubDate>Tue, 07 Jul 2020 11:59:42 +0000</pubDate>
				<guid isPermaLink="false">https://profesis.ckait.cz/?post_type=dokumenty&#038;p=1381</guid>

					<description><![CDATA[Požadavky geometrické přesnosti schodišť a šikmých ramp s dokončeným povrchem. Cílem tohoto standardu je stanovit pravidla pro kontrolu a vyhodnocení geometrické přesnosti schodišť a šikmých ramp s dokončeným povrchem s ohledem na technologické možnosti provedení konstrukce při zachování co největší bezpečnosti pohybu po těchto konstrukcích.]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>Autor:</strong> <a href="/autori/vesela-linda/">Ing. Linda Veselá, Ph.D.</a></p>



<p class="wp-block-paragraph"><strong>Stav:</strong> vydání únor 2021</p>



<p class="wp-block-paragraph"><strong>Účinnost:</strong> od 1. 7. 2021</p>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong>JEDNOTLIVÁ VYDÁNÍ:</strong></p>



<p class="wp-block-paragraph"><strong>Účinnost verze 1:</strong> od 1. 7. 2021</p>



<div class="wp-block-file"><a id="wp-block-file--media-0eaa0dda-90f3-4e5f-8b5a-4c643796927a" href="https://profesis.ckait.cz/wp-content/uploads/2020/07/ts-ckait-02-2021.pdf">TS 02-2021 ČKAIT ve formátu PDF ke stažení</a><a href="https://profesis.ckait.cz/wp-content/uploads/2020/07/ts-ckait-02-2021.pdf" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-0eaa0dda-90f3-4e5f-8b5a-4c643796927a">Stáhnout</a></div>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong><a href="/upozorneni-k-textum">Upozornění k textu</a></strong></p>



<hr class="wp-block-separator has-css-opacity is-style-wide"/>



<h3 class="wp-block-heading" id="predmluva">PŘEDMLUVA</h3>



<p class="wp-block-paragraph">Schodiště a šikmé rampy jsou nedílnou součástí většiny budov. Podléhají stejným technologickým principům a omezením jako ostatní stavební konstrukce. Schodiště a šikmé rampy musí splňovat základní technické požadavky, včetně bezpečnosti, která je do značné míry ovlivněna jejich navrženou geometrií a přesností skutečných rozměrů.</p>



<p class="wp-block-paragraph">Požadavky na vybrané technické parametry (rozměry, sklon, protiskluznost) schodišťových stupňů a šikmých ramp jsou definovány v českých technických normách a předpisech. Právní předpisy a technické normy stanoví zejména technické požadavky na navrhování schodišť a šikmých ramp, ale nestanoví požadavky na jejich provádění.</p>



<p class="wp-block-paragraph">Obecně lze technické požadavky shrnout následovně:</p>



<ul class="wp-block-list">
<li>Všechny stupně v jednom schodišťovém rameni musí mít stejnou výšku a šířku a musí být vodorovné, bez sklonu v příčném nebo podélném směru.</li>



<li>Podélný sklon ramene šikmé rampy má být konstantní po celé jeho délce. Je-li výšková úroveň překonávána jednou šikmou rampou se dvěma, popř. více rameny, má být podélný sklon všech ramen stejný.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">V praxi se setkáváme se situacemi, kdy stavebníci využívají ustanovení i technických norem a předpisů ve svůj prospěch a odmítnou převzít dokončené schodiště. Jako argument používají výše uvedené formulace a vyžadují, aby dokončené konstrukce měly nulové odchylky geometrické přesnosti. Výše uvedené formulace nelze brát bezvýhradně, protože z technologického hlediska není možné zhotovit schodišťové stupně bez určitých odchylek těchto rozměrů. Odchylky geometrické přesnosti dokončených konstrukcí jsou technologicky nevyhnutelné, což připouští i sami vydavatelé závazných předpisů v rámci svých vyjádření k této problematice.</p>



<p class="wp-block-paragraph">Cílem tohoto standardu je stanovit pravidla pro kontrolu a vyhodnocení geometrické přesnosti schodišť a šikmých ramp s dokončeným povrchem s ohledem na technologické možnosti provedení konstrukce při zachování co největší bezpečnosti pohybu po těchto konstrukcích.</p>



<p class="wp-block-paragraph"></p>



<hr class="wp-block-separator has-css-opacity is-style-wide"/>



<p class="wp-block-paragraph"><strong>Technický standard ČKAIT</strong> je doporučený dokument obsahující technické informace, které mají být respektovány, a instrukce popisující činnost, která se má provést. Stanovuje technické požadavky, které má stavební konstrukce, proces, nebo služba splňovat. Technický standard může také uvádět postupy, jejichž pomocí lze určit, zda jsou dané požadavky splněny. Technické standardy nejsou obecně závazné, jsou to však odborně kvalifikované předpisy, na které se mohou odkazovat smluvní strany při specifikaci předmětu smlouvy a podmínek jejího plnění nebo státní autorita ve svých obecně závazných předpisech. </p>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong>OBSAH</strong></p>


<figure class="wp-block-table">
<table style="border-style: hidden;" cellspacing="0" cellpadding="0" border="0">
<tbody>
<tr>
<td style="border-style: hidden; width: 15px; text-align: right;">&nbsp;</td>
<td style="border-style: hidden;"><a href="#predmluva"><strong>Předmluva</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>1</strong></td>
<td style="border-style: hidden;"><a href="#1"><strong>Předmět</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>2</strong></td>
<td style="border-style: hidden;"><a href="#2"><strong>Termíny a definice</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.1</td>
<td style="border-style: hidden;"><a href="#2-1">Schodiště (Staircase)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.2</td>
<td style="border-style: hidden;"><a href="#2-2">Atypické schodiště (Atypical staircase)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.3</td>
<td style="border-style: hidden;"><a href="#2-3">Šikmá rampa (Sliding ramp)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.4</td>
<td style="border-style: hidden;"><a href="#2-4">Schodišťové rameno (Flight of stairs)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.5</td>
<td style="border-style: hidden;"><a href="#2-5">Rameno šikmé rampy (Flight of sliding ramp)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.6</td>
<td style="border-style: hidden;"><a href="#2-6">Výstupní čára (Pitch line)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.7</td>
<td style="border-style: hidden;"><a href="#2-7">Sklon ramene (α) (Pitch)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.8</td>
<td style="border-style: hidden;"><a href="#2-8">Stupeň (Schodišťový stupeň) (Stair step)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.9</td>
<td style="border-style: hidden;"><a href="#2-9">Stupnice (Tread)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.10</td>
<td style="border-style: hidden;"><a href="#2-10">Výška stupně (h) (Rise)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.11</td>
<td style="border-style: hidden;"><a href="#2-11">Šířka stupně (b) (Going)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.12</td>
<td style="border-style: hidden;"><a href="#2-12">Mezní odchylka (Permitted deviation)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>3</strong></td>
<td style="border-style: hidden;"><a href="#3"><strong data-rich-text-format-boundary="true">Navrhování stupňů schodišťového ramene nebo ramene šikmé rampy s dokončenou povrchovou úpravou</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">3.1 <strong><br /></strong></td>
<td style="border-style: hidden;"><a href="#3-1">Zjednodušený návrh rozměru a tvaru schodišť a/nebo šikmých ramp</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">&nbsp;3.2</td>
<td style="border-style: hidden;"><a href="#3-2">Podrobný návrh rozměru a tvaru schodišť a/nebo šikmých ramp</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>4</strong></td>
<td style="border-style: hidden;"><a href="#4"><strong data-rich-text-format-boundary="true">Doporučené odchylky geometrické přesnosti schodišťových ramen a ramen šikmých ramp, které vyplývají z provádění</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.1</td>
<td style="border-style: hidden;"><a href="#4-1">Odchylka šířky schodišťových ramen a šikmých ramp</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.2</td>
<td style="border-style: hidden;"><a href="#4-2">Odchylka sklonu schodišťových ramen a šikmých ramp</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.3</td>
<td style="border-style: hidden;"><a href="#4-3">Odchylka geometrické přesnosti schodišťových stupňů a podest s povrchovou úpravou</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>5</strong></td>
<td style="border-style: hidden;"><a href="#5"><strong data-rich-text-format-boundary="true">Měření geometrických parametrů schodišť a šikmých ramp</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.1</td>
<td style="border-style: hidden;"><a href="#5-1">Použitá měřidla</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.2</td>
<td style="border-style: hidden;"><a href="#5-2">Postup měření</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.3</td>
<td style="border-style: hidden;"><a href="#5-3">Vyhodnocení přesnosti měření</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>6</strong></td>
<td style="border-style: hidden;"><a href="#6"><strong data-rich-text-format-boundary="true">Literatura, citované normy a předpisy</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">&nbsp;</td>
<td style="border-style: hidden;"><a href="#priloha-1"><strong data-rich-text-format-boundary="true">Příloha 1 – Požadované rozměry schodišťových ramen a šikmých ramp</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">&nbsp;</td>
<td style="border-style: hidden;"><a href="#priloha-2"><strong data-rich-text-format-boundary="true">Příloha 2 – Bezpečnost pohybu po schodišti a šikmé rampě</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">&nbsp;</td>
<td style="border-style: hidden;"><strong data-rich-text-format-boundary="true"><a href="#priloha-3">Příloha 3 – Posouzení návrhu schodiště z hlediska úrazovosti</a></strong></td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<hr class="wp-block-separator has-css-opacity is-style-wide"/>



<h3 class="wp-block-heading" id="1">1 PŘEDMĚT</h3>



<p class="wp-block-paragraph">Technický standard ČKAIT stanoví požadavky geometrické přesnosti schodišť a šikmých ramp s dokončeným povrchem, pokud je projektant nenavrhne podrobněji.</p>



<p class="wp-block-paragraph">Tento standard se nevztahuje na:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>pohyblivá schodiště a rampy;</li>



<li>schodiště a šikmé rampy tvořící součást technologických vybavení a zařízení podle&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=502315&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN EN ISO 14122-3</a>:2017;</li>



<li>vnitřní a venkovní šikmé rampy určené pouze pro pojezd vozidel a jízdních kol;</li>



<li>schodiště a šikmé rampy při obnově památkově chráněných budov.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">Tento Technický standard ČKAIT platí pro návrh a kontrolu geometrické přesnosti schodišť, vyrovnávacích stupňů a šikmých ramp s dokončeným povrchem. Pro změny dokončených staveb lze tento standard použít přiměřeně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2">2 TERMÍNY A DEFINICE</h3>



<p class="wp-block-paragraph">Použité termíny a definice vycházejí ze souvisejících technických norem <a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank">ČSN 73 4130</a> a <a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17347&amp;cid=5" target="_blank">ČSN 73 0202</a>.<br>Pro účely tohoto dokumentu platí dále uvedené termíny a definice.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-1">2.1 SCHODIŠTĚ (STAIRCASE)</h3>



<p class="wp-block-paragraph">Stavební konstrukce určená k překonávání rozdílů výškových úrovní chůzí, skládající se ze schodišťových ramen a podest.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-2">2.2 ATYPICKÉ SCHODIŠTĚ (ATYPICAL STAIRCASE)</h3>



<p class="wp-block-paragraph">Schodiště, jehož geometrické parametry nejsou definovány normou nebo předpisem.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>Schodiště, jehož schodišťové rameno není přímé, zakřivené nebo smíšené, ale má jiný půdorysný tvar (například schodiště se šikmým schodišťovým ramenem). Dále schodiště, které má schodišťové rameno, jehož nástupní (první, nejnižší) nebo výstupní (poslední, nejvyšší) schodišťový stupeň nemá stejnou výšku v rámci šířky schodišťového ramene. Zpravidla se jedná o schodiště, které slouží k vyrovnání výškových rozdílů mezi úrovní vstupu do budovy a původním terénem nebo k vyrovnání výškových rozdílů mezi dvěma komunikacemi.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-3">2.3 ŠIKMÁ RAMPA (SLIDING RAMP)</h3>



<p class="wp-block-paragraph">Stavební konstrukce tvořená skloněnou rovinou, popř. zakřivenou plochou, určená k překonávání rozdílu výškových úrovní chůzí nebo pojezdem, skládající se z ramen rampy a z podest. Za šikmou rampu se nepovažuje konstrukce pro překonání výškového rozdílu v terénu, která nesouvisí se stavbou.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-4">2.4 SCHODIŠŤOVÉ RAMENO (FLIGHT OF STAIRS)</h3>



<p class="wp-block-paragraph">Souvislá a vzájemně na sebe bezprostředně navazující řada nejméně tří schodišťových stupňů spojující dvě různé výškové úrovně. Je-li rozdíl výškových úrovní překonán jedním nebo dvěma schodišťovými stupni, nejedná se o schodišťové rameno, ale o vyrovnávací výškové stupně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-5">2.5 RAMENO ŠIKMÉ RAMPY (FLIGHT OF SLIDING RAMP)</h3>



<p class="wp-block-paragraph">Souvislá, nepřerušená skloněná plocha spojující dvě různé výškové úrovně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-6">2.6 VÝSTUPNÍ ČÁRA (PITCH LINE)</h3>



<p class="wp-block-paragraph">Výstupní čára schodišťového ramene je myšlená čára spojující souvisle přední hrany nástupního a výstupního stupně každého schodišťového ramene v teoretické ose výstupu. Na výstupní čáře schodišťového ramene musí mít stupeň navržený rozměr (šířku stupně <em>b</em> a výšku stupně <em>h</em>).</p>



<p class="wp-block-paragraph">Výstupní čára ramene šikmé rampy je myšlená čára spojující souvisle hrany počátku a konce sklonu ramene šikmé rampy vzhledem k vodorovné rovině podest v teoretické ose výstupu.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>Schodišťové rameno může mít více výstupních čar.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-7">2.7 SKLON RAMENE (<em>α</em>) (PITCH)</h3>



<p class="wp-block-paragraph">Sklon schodišťového ramene je úhel ve svislé rovině mezi výstupní čarou a vodorovnou rovinou. Sklon ramene šikmé rampy je úhel ve svislé rovině mezi výstupní čarou a vodorovnou rovinou. Sklon ramene může být vyjádřen také tangentou úhlu α, tj. podílem výšky a délky ramene.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-8">2.8 STUPEŇ (SCHODIŠŤOVÝ STUPEŇ) (STAIR STEP)</h3>



<p class="wp-block-paragraph">Prvek k překonání výškového rozdílu, který má požadované rozměry.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-9">2.9 STUPNICE (TREAD)</h3>



<p class="wp-block-paragraph">Nášlapná horní vodorovná plocha stupně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-10">2.10 VÝŠKA STUPNĚ (<em>h</em>) (RISE)</h3>



<p class="wp-block-paragraph">Svislá vzdálenost stupnic dvou následujících stupňů.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-11">2.11 ŠÍŘKA STUPNĚ (<em>b</em>) (GOING)</h3>



<p class="wp-block-paragraph">Vodorovná vzdálenost předních hran stupnic dvou následujících stupňů měřená na výstupní čáře.</p>


<div class="wp-block-image">
<figure class="aligncenter size-large" id="obr-2-1"><img loading="lazy" decoding="async" width="386" height="272" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts02-obr2-1.gif" alt="" class="wp-image-1107"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 2.1</em>&nbsp;&nbsp;Části schodišťového ramene</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-12">2.12 MEZNÍ ODCHYLKA (PERMITTED DEVIATION)</h3>



<p class="wp-block-paragraph">Rozdíl mezi skutečnou hodnotou stanovenou měřením na dokončené konstrukci a hodnotou navrženou nebo požadovanou. Mezní odchylka je parametr geometrické přesnosti, který může nabývat kladných i záporných hodnot (bývá uváděn ve tvaru ±5 mm nebo +2 mm/ -1 mm).</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3">3 NAVRHOVÁNÍ STUPŇŮ SCHODIŠŤOVÉHO RAMENE NEBO RAMENE ŠIKMÉ RAMPY S DOKONČENOU POVRCHOVOU ÚPRAVOU</h3>



<p class="wp-block-paragraph">(1) Při návrhu a provádění schodišť a šikmých ramp je třeba počítat s geometrickou přesností nejen samotné konstrukce schodiště, ale i s odchylkami geometrické přesnosti ohraničujících svislých konstrukcí a povrchových úprav stěn a konstrukce schodiště. K minimálním (limitním) rozměrům je tak potřeba připočíst odchylky geometrické přesnosti skutečného provedení nosné konstrukce schodiště/šikmé rampy, ohraničující svislé konstrukce a jejich povrchové úpravy.</p>



<p class="wp-block-paragraph">(2) Rozměry a tvar schodišť/šikmých ramp musí být navrženy tak, aby při reálných odchylkách při provádění stavebních konstrukcí bylo dosaženo návrhových/požadovaných rozměrů. Doporučené postupy návrhu jsou uvedeny v následujících kapitolách.</p>



<p class="wp-block-paragraph">(3) Podkladem pro stanovení navrhovaných rozměrů musí být minimální (limitní) rozměry stanovené právním předpisem, technickou normou nebo funkčními parametry a odchylky geometrické přesnosti jednotlivých parametrů uvedené v ČSN pro provádění stavebních konstrukcí a povrchových úprav.</p>



<p class="wp-block-paragraph">(4) Pokud není určitá odchylka geometrické přesnosti řešena příslušnou ČSN, je její hodnota doporučena na základě jiné obdobné české nebo zahraniční technické normy.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3-1">3.1 ZJEDNODUŠENÝ NÁVRH ROZMĚRU A TVARU SCHODIŠŤ A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph">(1) Zjednodušený návrh rozměru schodišť a šikmých ramp lze použít v prvních fázích přípravných a projektových prací (studie, DÚR, DSP), kdy nejsou často známy všechny údaje potřebné ke stanovení bezpečného navýšení tvaru a rozměrů schodiště nebo šikmé rampy.</p>



<p class="wp-block-paragraph">(2) Pokud je nějakým předpisem navrhovaný rozměr limitován (např. minimální šířka, maximální výška, minimální nebo maximální sklon), je v projektu vhodné tento limitovaný rozměr zvětšit nebo zmenšit o hodnoty uvedené v&nbsp;<em>tab. 3.1</em>. Zamezí se tím problémům, které mohou vzniknout vlivem výrobních odchylek, při přeměřování hotové konstrukce.</p>



<p class="wp-block-paragraph">Podrobné stanovení výrobních odchylek je v&nbsp;<a href="#4">kap. 4</a>.</p>



<p class="wp-block-paragraph"><em>Tab. 3.1</em>&nbsp;&nbsp;Doporučená úprava navržených geometrických parametrů schodišť a šikmých ramp</p>


<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td><strong>Geometrický parametr</strong></td>
<td style="text-align: center;"><strong>Doporučená minimální úprava parametru</strong></td>
</tr>
<tr>
<td>Šířka schodišťového ramene/rampy</td>
<td style="text-align: center;">+50 mm</td>
</tr>
<tr>
<td>Minimální podélný sklon (maximum)</td>
<td style="text-align: center;">+1,5 %</td>
</tr>
<tr>
<td>Maximální podélný sklon</td>
<td style="text-align: center;">-1,5 %</td>
</tr>
<tr>
<td>Výška schodišťového stupně</td>
<td style="text-align: center;">-5 mm</td>
</tr>
<tr>
<td>Šířka schodišťového stupně</td>
<td style="text-align: center;">+5 mm</td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3-2">3.2 PODROBNÝ NÁVRH ROZMĚRU A TVARU SCHODIŠŤ A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph">(1) Podrobný návrh rozměru schodišť a šikmých ramp lze použít v případě, kdy je v rámci projektových prací přesně známo materiálové složení konstrukce schodiště a ohraničujících konstrukcí.</p>



<p class="wp-block-paragraph">(2) Pro podrobný návrh geometrických parametrů schodišť a šikmých ramp včetně navýšení na případné odchylky geometrické přesnosti pro provádění lze v rámci projektových prací využít postup výpočtu, který je popsán níže včetně všech proměnných, které by měly být ve výpočtu vzaty v úvahu.</p>



<p class="wp-block-paragraph">(3) Požadavky na minimální a maximální rozměry (světlá šířka, sklon, výška nebo šířka schodišťového stupně) jsou uvedeny v příloze.</p>



<p class="wp-block-paragraph">(4) Doporučené odchylky geometrické přesnosti, které by měl použít projektant jako podklad pro podrobný výpočet navrhovaných rozměrů a tvaru schodišť nebo šikmých ramp, jsou uvedeny v&nbsp;<a href="#4">kap. 4</a>. Jedná se o odchylky, které lze reálně dosáhnout při provádění stavebních konstrukcí a dokončovacích prací.</p>



<p class="wp-block-paragraph">(5)&nbsp;<strong>Doporučená minimální navrhovaná světlá šířka</strong>&nbsp;(<em>l</em><sub>ss,dop</sub>) schodišťového ramene/šikmé rampy se stanoví podle následujícího vztahu</p>



<div class="wp-block-katex-display-block katex-eq" data-katex-display="true"><pre>\begin{gathered}
l_{ss,dop} = l_{norm} + \Delta l_{hk} + t_{ps}
\end{gathered}</pre></div>



<p class="has-text-align-right wp-block-paragraph">(3.1)</p>



<p class="wp-block-paragraph">Kde je</p>



<p class="wp-block-paragraph"><em>l</em><sub>norm</sub> &#8230; požadovaná minimální světlá šířka (viz&nbsp;<a href="#priloha-1">příloha č. 1</a>)<br><em>Δl</em><sub>hk</sub> &#8230; odchylka vzdálenosti protilehlých hrubých svislých konstrukcí (v případě schodišťového ramene, které ohraničují svislé konstrukce) nebo odchylka šířky schodišťového ramene (v případě, že schodišťové rameno není ohraničeno, nebo je ohraničeno jen z jedné strany svislými konstrukcemi) (viz&nbsp;<a href="#4-1">kap. 4.1</a>)<br><em>t</em><sub>ps</sub> &#8230; tloušťka navrhované povrchové úpravy svislé konstrukce</p>



<p class="wp-block-paragraph">(6)&nbsp;<strong>Doporučený minimální navrhovaný sklon</strong>&nbsp;(<em>α</em><sub>min,dop</sub>) schodišťového ramene/šikmé rampy se stanoví podle následujícího vztahu</p>



<div class="wp-block-katex-display-block katex-eq" data-katex-display="true"><pre>\begin{gathered}
\alpha_{min,dop} = \alpha_{min,norm} + \Delta \alpha
\end{gathered}</pre></div>



<p class="has-text-align-right wp-block-paragraph">(3.2)</p>



<p class="wp-block-paragraph">Kde je</p>



<p class="wp-block-paragraph"><em>α</em><sub>min,norm</sub> &#8230; požadovaný minimální sklon (viz&nbsp;<a href="#priloha-1">příloha č. 1</a>)<br><em>Δα</em> &#8230; odchylka sklonu (viz&nbsp;<a href="#4-2">kap. 4.2</a>)</p>



<p class="wp-block-paragraph">(7)&nbsp;<strong>Doporučený maximální navrhovaný sklon</strong>&nbsp;(<em>α</em><sub>max,dop</sub>) schodišťového ramene/šikmé rampy se stanoví podle následujícího vztahu</p>



<div class="wp-block-katex-display-block katex-eq" data-katex-display="true"><pre>\begin{gathered}
\alpha_{min,dop} = \alpha_{min,norm} - \Delta \alpha
\end{gathered}</pre></div>



<p class="has-text-align-right wp-block-paragraph">(3.3)</p>



<p class="wp-block-paragraph">Kde je<br><em>α</em><sub>max,norm</sub> &#8230; požadovaný maximální sklon (viz&nbsp;<a href="#priloha-1">příloha č. 1</a>)<br><em>Δα</em> &#8230; odchylka sklonu (viz&nbsp;<a href="#4-2">kap. 4.2</a>)</p>



<p class="wp-block-paragraph">(8) Odchylky jsou uvažovány v&nbsp;<strong>absolutních hodnotách</strong>.</p>



<p class="wp-block-paragraph">(9) Přípustné mezní odchylky geometrických parametrů by měly být uvedeny ve výkresech jedním z následujících způsobů:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>stanovením mezních odchylek v rámci kótovaných rozměrů, např. 1200 (±20) nebo 1200 (+30; -20);</li>



<li>stanovením mezních odchylek v rámci poznámek k legendě výkresu.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">(10) Pokud nejsou v návrhu stavby uvedeny mezní odchylky geometrických parametrů schodišť a šikmých ramp, předpokládá se, že návrhové rozměry jsou stanoveny tak, aby skutečné rozměry vyhověly platným předpisům i po započtení mezních odchylek geometrické přesnosti. Odchylky geometrické přesnosti dokončených konstrukcí, které jsou v souladu s tímto předpisem, se nepovažují za vadu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4">4 DOPORUČENÉ ODCHYLKY GEOMETRICKÉ PŘESNOSTI SCHODIŠŤOVÝCH RAMEN A RAMEN ŠIKMÝCH RAMP, KTERÉ VYPLÝVAJÍ Z PROVÁDĚNÍ</h3>



<p class="wp-block-paragraph">(1) V této kapitole jsou uvedeny doporučené odchylky geometrické přesnosti rozměrů a tvaru schodišť a šikmých ramp, které by měly být splněny v rámci provádění stavebních konstrukcí a dokončovacích prací.</p>



<p class="wp-block-paragraph">(2) Doporučené hodnoty vycházejí z ustanovení norem ČSN pro provádění konstrukcí a dokončovacích prací. Pokud není určitá odchylka geometrické přesnosti řešena příslušnou ČSN, je její hodnota doporučena na základě jiné obdobné české nebo zahraniční technické normy.</p>



<p class="wp-block-paragraph">(3) Níže uvedené odchylky geometrické přesnosti schodišť platí i pro výrobu prefabrikovaných schodišťových ramen a musí být uvedeny v zadávací dokumentaci.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br><a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=79965&amp;cid=5" target="_blank">ČSN EN 14843</a>:2008<a href="#literatura-7">[7]</a> pro prefabrikovaná schodiště neřeší geometrii schodišť z hlediska funkčnosti, tyto odchylky je možné stanovit v rámci národních předpisů. Odchylky geometrické přesnosti uvedené v&nbsp;<a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=79965&amp;cid=5" target="_blank">ČSN EN 14843</a>:2008<a href="#literatura-7">[7]</a>, resp.&nbsp;<a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=94048&amp;cid=5" target="_blank">ČSN EN 13369</a>:2019<a href="#literatura-6">[6]</a> se použijí v případě, že nejsou stanoveny přísnější požadavky v národních předpisech nebo zadávací dokumentaci.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4-1">4.1 ODCHYLKA ŠÍŘKY SCHODIŠŤOVÝCH RAMEN A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph">(1) Šířka schodišťových ramen a šikmých ramp může být ovlivněna především těmito geometrickými parametry:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>odchylkou vzdálenosti protilehlých svislých konstrukcí bez povrchových úprav (tzv. hrubých konstrukcí), které ohraničují schodišťové rameno/šikmou rampu;</li>



<li>odchylkou šířky schodišťových ramen (v případě, že schodišťové rameno/šikmá rampa není ohraničena, nebo je ohraničena jen z jedné strany svislými konstrukcemi);</li>



<li>tloušťkou povrchové úpravy ohraničujících protilehlých svislých konstrukcí.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">(2) Při návrhu a provádění nosné konstrukce schodišť je třeba počítat s geometrickou přesností monolitické nebo prefabrikované konstrukce nejen z pohledu schodišťového ramene, ale i z pohledu ohraničujících svislých konstrukcí.</p>



<p class="wp-block-paragraph">(3) Pro výpočet šířky schodišťových ramen a šikmých ramp je potřeba stanovit parametry odchylky geometrické přesnosti podle půdorysného tvaru schodišťového ramene nebo šikmé rampy:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>V případě schodišťového ramene (šikmé rampy) z obou stran ohraničeného svislými konstrukcemi bude odchylka šířky schodišťových ramen nebo šikmých ramp stanovena na základě mezní odchylky&nbsp;<strong>vzdálenosti protilehlých konstrukcí</strong>&nbsp;uvedené v <a href="#tab-4-1"><em>tab. 4.1</em></a>, které schodišťové rameno nebo šikmou rampu ohraničují;</li>



<li>V případě schodišťového ramene (šikmé rampy) stojícího volně v prostoru bude odchylka šířky schodišťových ramen nebo šikmých ramp stanovena na základě mezní odchylky šířky schodišťového ramene nebo šikmé rampy uvedené v <em><a href="#tab-4-2">tab. 4.2</a></em>;</li>



<li>V případě schodišťového ramene (šikmé rampy) ohraničeného svislou konstrukcí pouze z jedné strany se pro stanovení odchylky šířky schodišťových ramen nebo šikmých ramp použije větší z hodnot uvedených v <em><a href="#tab-4-1">tab. 4.1</a></em> nebo <em><a href="#tab-4-2">tab. 4.2</a></em>.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">(4) Mezní odchylka&nbsp;<strong>vzdálenosti protilehlých konstrukcí</strong>&nbsp;bez povrchových úprav se stanoví podle typu ohraničující svislé nosné konstrukce v závislosti na navrhované šířce schodišťového ramene nebo šikmé rampy.</p>



<p class="wp-block-paragraph" id="tab-4-1"><em>Tab. 4.1</em>&nbsp;&nbsp;Mezní odchylka vzdálenosti protilehlých svislých konstrukcí bez povrchových úprav</p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="width: 27.1354%;"><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td style="text-align: center; vertical-align: middle; width: 28.1866%;"><strong>Betonové monolitické a prefabrikované konstrukce (sloupy, stěny)</strong></td>
<td style="text-align: center; vertical-align: middle; width: 13.929%;"><strong>Ocelové konstrukce (sloupy)<sup>1)</sup></strong></td>
<td style="text-align: center; vertical-align: middle; width: 11.2352%;"><strong>Zděné konstrukce<sup>2)</sup></strong></td>
<td style="text-align: center; vertical-align: middle; width: 19.4481%;"><strong>Dřevěné a ostatní konstrukce (sloupy, stěny)</strong></td>
</tr>
<tr>
<td style="width: 27.1354%;" rowspan="3">Vzdálenost protilehlých svislých konstrukcí bez povrchových úprav</td>
<td style="text-align: center; vertical-align: middle; width: 28.1866%;" rowspan="3">±20 mm pro <em>L</em> ≤ 12 m<br />±L / 600 pro <em>L</em> &gt; 12 m, max. 60 mm</td>
<td style="text-align: center; vertical-align: middle; width: 13.929%;" rowspan="3">Třída 1:<br />±10&nbsp;mm pro <em>L</em> ≤ 5 m,<br />±0,2 (<em>L</em>+45) mm pro <em>L</em> &gt; 5 m<br />Třída 2:<br />±7 mm pro <em>L</em> ≤ 5 m,<br />±0,2 (<em>L</em> + 30) mm pro <em>L</em> &gt; 5&nbsp;m</td>
<td style="text-align: center; vertical-align: middle; width: 11.2352%;" rowspan="3">±40 mm</td>
<td style="text-align: center; vertical-align: middle; width: 19.4481%;">±20 mm pro <em>L</em> ≤ 4 m</td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle; width: 19.4481%;">±25 mm pro 4 m &lt; <em>L</em> ≤ 8 m</td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle; width: 19.4481%;">±30 mm pro 8 m &lt; <em>L</em> ≤ 16 m</td>
</tr>
<tr>
<td style="width: 27.1354%;">Norma</td>
<td style="text-align: center; vertical-align: middle; width: 28.1866%;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=86077&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 13670</a>, obr C.2c</td>
<td style="width: 13.929%; text-align: center; vertical-align: middle;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=506872&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 1090-2</a></td>
<td style="text-align: center; vertical-align: middle; width: 11.2352%;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=77706&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 1996-2</a>, tab. 3.1</td>
<td style="text-align: center; vertical-align: middle; width: 19.4481%;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 0205</a>, tab. A.1</td>
</tr>
<tr>
<td style="width: 99.9343%;" colspan="5">Kde&nbsp;<em>L</em>&nbsp;je vzdálenost mezi protilehlými konstrukcemi bez dokončeného povrchu ohraničující schodišťové rameno/šikmou rampu nebo šířka schodišťového ramene/šikmé rampy.</td>
</tr>
<tr>
<td style="width: 99.9343%;" colspan="5"><sup data-rich-text-format-boundary="true">1)</sup>&nbsp;U ocelových konstrukcí jsou hodnoty odchylek uvedeny pro dvě toleranční třídy. Zvolená toleranční třída musí být specifikována v prováděcí dokumentaci. Pokud v dokumentaci není uvedena toleranční třída, je závazná toleranční třída 1.</td>
</tr>
<tr>
<td style="width: 99.9343%;" colspan="5"><sup data-rich-text-format-boundary="true">2)</sup> Odchylka vzdálenosti pro zděné konstrukce není v <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=77706&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 1996-2</a>:2007 stanovena. Uvedená hodnota odpovídá součtu maximálních odchylek svislosti protilehlých svislých zděných stěn v rámci jednoho podlaží, která činí ±20 mm.</td>
</tr>
<tr>
<td style="width: 99.9343%;" colspan="5"><sup data-rich-text-format-boundary="true">3)</sup> Odchylky vzdálenosti protilehlých konstrukcí pro dřevěné a ostatní konstrukce (např. sádrokartonové) nejsou v aktuálně platných českých prováděcích normách stanoveny. V případě potřeby lze použít doporučené hodnoty uvedené v <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 0205</a>:1995.</td>
</tr>
<tr>
<td style="width: 99.9343%;" colspan="5">V případě souběhu konstrukcí z různých materiálů (např. protilehlá betonová a zděná stěna, nebo zděná stěna a betonové schodiště) se pro odchylku šířky použije odchylka s větší hodnotou.</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(5) Mezní odchylka&nbsp;<strong>šířky</strong>&nbsp;schodišťového ramene nebo šikmé rampy se stanoví podle typu nosné konstrukce v závislosti na navrhované šířce schodišťového ramene nebo šikmé rampy.</p>



<p class="wp-block-paragraph" id="tab-4-2"><em>Tab. 4.2</em>&nbsp;&nbsp;Mezní odchylka šířky schodišťového ramene nebo šikmé rampy</p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="width: 44.9409%;"><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td style="width: 54.9934%;"><strong data-rich-text-format-boundary="true">Betonové monolitické, prefabrikované, dřevěné a ostatní konstrukce</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; width: 44.9409%;" rowspan="3">Odchylka šířky schodišťového ramene nebo šikmé rampy</td>
<td style="text-align: center; width: 54.9934%;">±20 mm pro <em>L</em> ≤ 4 m</td>
</tr>
<tr>
<td style="text-align: center; width: 54.9934%;">±25 mm pro 4 m &lt; <em>L</em> ≤ 8 m</td>
</tr>
<tr>
<td style="text-align: center; width: 54.9934%;">±30 mm pro 8 m &lt; <em>L</em> ≤ 16 m</td>
</tr>
<tr>
<td style="width: 44.9409%;">Norma</td>
<td style="width: 54.9934%; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 0205</a>:1995, tab. A.1</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(6)&nbsp;<strong>Tloušťka povrchové úpravy</strong>&nbsp;ohraničujících protilehlých svislých konstrukcí. Pokud se povrchová úprava svislých konstrukcí v projektové dokumentaci nekótuje, musí být v rámci navrhované světlé šířky schodišťového ramene nebo šikmé rampy počítáno s rezervou, která zahrnuje tloušťku navržené povrchové úpravy ohraničujících svislých stěn:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>z jedné strany schodišťového ramene/šikmé rampy bude&nbsp;<em>t</em><sub>ps</sub>&nbsp;= navrhovaná tloušťka povrchové úpravy stěny;</li>



<li>z obou stran schodišťového ramene/šikmé rampy bude&nbsp;<em>t</em><sub>ps</sub>&nbsp;= navrhovaná tloušťka povrchové úpravy první stěny + navrhovaná tloušťka povrchové úpravy protilehlé stěny;</li>



<li>schodišťového ramene/šikmé rampy, která není ohraničena svislou konstrukcí, bude&nbsp;<em>t</em><sub>ps</sub>&nbsp;= 0 mm.</li>
</ul>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4-2">4.2 ODCHYLKA SKLONU SCHODIŠŤOVÝCH RAMEN A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph">(1) Mezní odchylka&nbsp;<strong>podélného sklonu</strong>&nbsp;schodišťových ramen a šikmých ramp se stanoví v závislosti na jejich délce.</p>



<p class="wp-block-paragraph" id="tab-4-3"><em>Tab. 4.3</em>&nbsp;&nbsp;Mezní odchylka podélného sklonu schodišťových ramen a šikmých ramp</p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td><strong data-rich-text-format-boundary="true">Geometrický parametr</strong></td>
<td><strong data-rich-text-format-boundary="true">Betonové monolitické, prefabrikované, dřevěné a ostatní konstrukce</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;" rowspan="3">Odchylka podélného sklonu</td>
<td style="text-align: center;">±10 mm pro <em>L</em> ≤ 4 m</td>
</tr>
<tr>
<td style="text-align: center;">±12 mm pro 4 m &lt; <em>L</em> ≤ 8 m</td>
</tr>
<tr>
<td style="text-align: center;">±15 mm pro 8m &lt; <em>L</em> ≤ 16m</td>
</tr>
<tr>
<td>Norma</td>
<td style="text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 0205</a>:1995, tab. A.7</td>
</tr>
<tr>
<td colspan="2"><em data-rich-text-format-boundary="true">L</em>&nbsp;je délka ramene schodiště nebo šikmé rampy na výstupní čáře.</td>
</tr>
<tr>
<td colspan="2">Odchylka platí pro vztažnou délku v příslušném rozsahu délek, kolmo na nominální přímku sklonu.</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(2) Mezní odchylka&nbsp;<strong>příčného sklonu</strong>&nbsp;šikmé rampy musí být menší než 0,5 % šířky rampy.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4-3">4.3 ODCHYLKA GEOMETRICKÉ PŘESNOSTI SCHODIŠŤOVÝCH STUPŇŮ A PODEST S POVRCHOVOU ÚPRAVOU</h3>



<p class="wp-block-paragraph">(1) Mezní odchylka&nbsp;<strong>výšky a šířky</strong>&nbsp;schodišťových stupňů od navrhovaných (požadovaných rozměrů) je ±5 mm. Rozdíl výšek dvou po sobě následujících schodů smí být maximálně 5 mm.</p>



<p class="wp-block-paragraph">(2) Mezní odchylka&nbsp;<strong>šířky a délky</strong>&nbsp;podest odpovídá hodnotám uvedeným v <em><a href="#tab-4-2">tab. 4.2</a></em>.</p>



<p class="wp-block-paragraph">(3) Mezní odchylka&nbsp;<strong>rovinnosti</strong>&nbsp;povrchu schodišťového stupně a podesty může být maximálně ±2 mm pro délku ≤ 2 m.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>Mezní odchylka je standardně uvažována na vzdálenost 2 m. V případě, že bude mít kontrolovaný povrch rozměr menší než 2 m, mezní odchylka zůstává konstantní (neinterpoluje se).</p>



<p class="wp-block-paragraph">(4) Schodnice schodišťových stupňů a podest musí být vodorovné, bez příčného a podélného sklonu. Mezní&nbsp;<strong>odchylka od vodorovné roviny</strong>&nbsp;dokončených schodnic a podest může být maximálně:</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>±0,5 % na šířku schodišťového ramene (v podélném směru);</li>



<li>±1 % na šířku stupnice (příčném směru).</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">(5) Na schodištích a šikmých rampách, které jsou vystaveny srážkové nebo jiné vodě, se nesmí tvořit kaluže. U schodišť, kde je požadováno odvodnění, může být v odůvodněných případech vytvořen sklon. Sklon dokončené konstrukce nesmí být větší než 2 % a nesmí být u dokončené konstrukce překročen. Povrch podest vnějších schodišť může mít podélný sklon ve směru sestupu nejvýše 7 %.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5">5 MĚŘENÍ GEOMETRICKÝCH PARAMETRŮ SCHODIŠŤ A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph">(1) Postupy měření geometrických parametrů stavebních konstrukcí jsou popsány v normách řady ČSN 73 0212:1993-1997<a href="#literatura-9">[9]</a>. Níže doplněna metodika měření geometrické přesnosti schodišťových stupňů, která není v platných normách popsána. Cílem této metodiky je stanovení jednotného postupu měření geometrické přesnosti.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-1">5.1 POUŽITÁ MĚŘIDLA</h3>



<p class="wp-block-paragraph">(1) Pro měření by měla být použita především měřidla, která jsou metrologicky navázána (kalibrována):</p>



<ul class="wp-block-list is-style-razeny-list-ABC">
<li>délkové měřidlo s dělením na 1 mm;</li>



<li>úhelník s pravým úhlem.</li>
</ul>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-2">5.2 POSTUP MĚŘENÍ</h3>



<p class="wp-block-paragraph">(1) Měří se&nbsp;<strong>výška a šířka všech stupňů</strong>&nbsp;v rámci jednoho schodišťového ramene. U schodišťových ramen se šířkou do 1500 mm se měření provádí na výstupní čáře schodišťového ramene. U schodišťových ramen širších než 1500 mm se měření provádí ve dvou liniích vedených souběžně s okrajem schodišťového ramene ve vzdálenosti cca 500 mm od zábradlí.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>Výstupní čarou u ramen přímých je přímka a umísťuje se půdorysně v ose ramene. Výstupní čarou u ramen zakřivených (točitých) je křivka a umísťuje se půdorysně ve vzdálenosti 1/3 šířky ramene od vnější hrany oblouku jeho zakřivení. Poloha výstupní čáry smíšených schodišť, přímých a zakřivených, se řídí její polohou v zakřivených částech. Výstupní čára atypických schodišťových ramen (šikmé schodišťové rameno) se umisťuje do <strong>teoretické</strong> osy výstupu.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full" id="obr-5-1"><img loading="lazy" decoding="async" width="476" height="290" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts02-obr5-1.gif" alt="" class="wp-image-1108"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 5.1</em>&nbsp;&nbsp;Měření rozměrů schodišťových stupňů standardního schodiště</p>


<div class="wp-block-image">
<figure class="aligncenter size-full" id="obr-5-2"><img loading="lazy" decoding="async" width="610" height="140" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts02-obr5-2.gif" alt="" class="wp-image-1109"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 5.2</em>&nbsp;&nbsp;Měření rozměrů schodišťových stupňů atypického schodiště</p>



<p class="wp-block-paragraph">(4)&nbsp;<strong>Výška stupně</strong>&nbsp;se měří vždy od horního líce jednoho stupně k hornímu líci následujícího stupně.&nbsp;<strong>Šířka stupně</strong>&nbsp;se měří od hrany čela jednoho stupně k hraně čela následujícího stupně. Rozměry stupňů se měří pomocí úhelníku a délkového měřidla.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full" id="obr-5-3"><img loading="lazy" decoding="async" width="477" height="137" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts02-obr5-3.gif" alt="" class="wp-image-1110"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 5.3</em>&nbsp;&nbsp;Měření výšky a šířky schodišťového stupně</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph"><strong>Poznámka:</strong><br>U schodišťových ramen, jejichž nástupní nebo výstupní stupeň nemá stejnou výšku v rámci celé šířky schodišťového ramene, se výška těchto stupňů neměří.</p>



<p class="wp-block-paragraph">(5)&nbsp;<strong>Místní rovinnost schodišťových stupňů</strong>&nbsp;se měří pomocí latě na podložkách a měrného klínku. Výška podložek by měla být 10 mm. Místní rovinnost se měří pomocí latě délky ≤ 2 m. Vždy je vyžadován minimálně 1 klad latě na každý kontrolovaný stupeň. Lať se musí v ploše umístit min 100 mm od hran a ohraničujících konstrukcí. Měření rovinnosti probíhá tak, že se změří největší a nejmenší prohlubeň pod latí, odečte se od nich výška podložek a výsledné hodnoty se porovnají s doporučenými odchylkami rovinnosti.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-3">5.3 VYHODNOCENÍ PŘESNOSTI MĚŘENÍ</h3>



<p class="wp-block-paragraph">(1) Schodiště je vyhovující z hlediska navržených rozměrů a rovinnosti, když se naměřené hodnoty geometrických parametrů neliší o více než příslušnou mezní odchylku od navrhovaných hodnot.</p>



<p class="wp-block-paragraph">(2) Při měření geometrických parametrů dochází ke vzniku nejistoty měření vlivem odchylky měřicích přístrojů, chyb vnesených lidským faktorem apod. Tato nejistota by měla být připočítána k odchylce měření v rámci vyhodnocení a posouzení shody změřených hodnot.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="6">6 LITERATURA, CITOVANÉ NORMY A PŘEDPISY</h3>



<p class="wp-block-paragraph" id="literatura-1">[1] Vyhláška MMR&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noreferrer noopener">č. 268/2009 Sb.</a>, o technických požadavcích na stavby, ve znění pozdějších předpisů</p>



<p class="wp-block-paragraph" id="literatura-2">[2] Vyhláška&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noreferrer noopener">č. 398/2009 Sb</a>., o obecných technických požadavcích zabezpečujících bezbariérové užívání staveb</p>



<p class="wp-block-paragraph" id="literatura-3">[3] Nařízení&nbsp;<a rel="noreferrer noopener" href="https://www.praha.eu/jnp/cz/o_meste/vyhlasky_a_narizeni/vyhledavani_v_pravnich_predpisech/narizeni_c_10_2016_sb_hl_m_prahy.html" target="_blank">č. 10/2016 Sb. hl. m. Prahy</a>, kterým se stanovují obecné požadavky na využívání území a technické požadavky na stavby v hlavním městě Praze (Pražské stavební předpisy) ve znění nařízení č. 14/2018 Sb. hl. m. Prahy</p>



<p class="wp-block-paragraph" id="literatura-4">[4]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=17348&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN 73 0205</a>&nbsp;– Geometrická přesnost ve výstavbě. Navrhování geometrické přesnosti. ČNI, Praha 1995</p>



<p class="wp-block-paragraph" id="literatura-5">[5]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN 73 4130</a>&nbsp;– Schodiště a šikmé rampy – Základní požadavky. ÚNMZ, Praha 2010</p>



<p class="wp-block-paragraph" id="literatura-6">[6]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=94048&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN EN 13369</a>&nbsp;– Společná ustanovení pro betonové prefabrikáty, ČAS, Praha 2019</p>



<p class="wp-block-paragraph" id="literatura-7">[7]&nbsp;<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=79965&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN EN 14843</a>&nbsp;– Betonové prefabrikáty – Schodiště, ČNI, Praha 2008</p>



<p class="wp-block-paragraph" id="literatura-8">[8] DIN 18 065 – Gebäudetreppen – Begriffe, Messregeln, Hauptmaße. Deutsches Institut für Normung e. V, 2011.</p>



<p class="wp-block-paragraph" id="literatura-9">[9] ČSN 73 0212 – Geometrická přesnost ve výstavbě. Kontrola přesnosti. Část 1–7, ČNI a ITN, Praha 1993–1997</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="prilohy"><strong>PŘÍLOHY</strong></h3>



<ul class="wp-block-list">
<li><a href="#priloha-1">Příloha 1 – Požadované rozměry schodišťových ramen a šikmých ramp</a></li>



<li><a href="#priloha-2">Příloha 2 – Bezpečnost pohybu po schodišti a šikmé rampě</a></li>



<li><a href="#priloha-3">Příloha 3 – Posouzení návrhu schodiště z&nbsp;hlediska úrazovosti</a></li>
</ul>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="priloha-1">PŘÍLOHA 1 – POŽADOVANÉ ROZMĚRY SCHODIŠŤOVÝCH RAMEN A ŠIKMÝCH RAMP</h3>



<p class="wp-block-paragraph" id="p1-1"><strong>P1-1 Požadované rozměry pro schodiště a šikmé rampy platné na území hlavního města Prahy</strong></p>



<p class="wp-block-paragraph" id="p1-1-1"><strong>P1-1.1 Stavby individuálního bydlení, byty</strong></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Parametr</strong></td>
<td style="text-align: center; vertical-align: middle;" colspan="3"><strong data-rich-text-format-boundary="true">Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle;" colspan="2"><strong data-rich-text-format-boundary="true">Nařízení&nbsp;<a href="https://www.praha.eu/jnp/cz/o_meste/vyhlasky_a_narizeni/vyhledavani_v_pravnich_predpisech/narizeni_c_10_2016_sb_hl_m_prahy.html" target="_blank" rel="noopener noreferrer">č. 10/2016 Sb. hl. m. Prahy</a></strong></td>
<td style="text-align: center; vertical-align: middle;"><strong data-rich-text-format-boundary="true">Vyhláška&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a></strong></td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka schodišťového ramene</td>
<td style="text-align: center; vertical-align: middle;">≥ 750 mm<sup>1)</sup></td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka podesty</td>
<td style="text-align: center; vertical-align: middle;">≥ průchodné šířce navazujícího schodišťového ramene</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Sklon schodišťového ramene</td>
<td style="text-align: center; vertical-align: middle;">≤ 35°<sup>2)</sup></td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Počet výšek stupňů v jednom schodišťovém rameni</td>
<td style="text-align: center; vertical-align: middle;">≤ 18</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Výška stupně na výstupní čáře</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupně na výstupní čáře</td>
<td style="text-align: center; vertical-align: middle;">≥ 180 mm</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupnice na výstupní čáře</td>
<td style="text-align: center; vertical-align: middle;">≥ 225 mm</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Poměr mezi výškou stupně <em>h</em> a šířkou stupně <em>b</em></td>
<td style="text-align: center; vertical-align: middle;">610 mm ≤ 2<em>h</em> + <em>b</em> ≤ 650 mm</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka rampy</td>
<td style="text-align: center; vertical-align: middle;">≥ 750 mm</td>
<td style="text-align: center; vertical-align: middle;">příloha č. 1 (6)</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Podélný sklon rampy</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Příčný sklon rampy</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
<td style="text-align: center; vertical-align: middle;">NPD</td>
</tr>
<tr>
<td colspan="4"><sup data-rich-text-format-boundary="true">1)</sup>&nbsp;Konstrukce zábradlí, popř. madel může do průchodné šířky ramene zasahovat nejvýše 100 mm.</td>
</tr>
<tr>
<td colspan="4"><sup data-rich-text-format-boundary="true">2)</sup>&nbsp;Nepřesáhne-li konstrukční výška podlaží ve stavbách individuálního bydlení a ve stavbách pro rodinnou rekreaci 3 m, může být sklon schodišťových ramen schodišť zvýšen až na 41°.</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-1-2"><strong>P1-1.2 Bezbariérově užívané stavby (viz<a href="#p1-4"> kap. P1-4</a>); ostatní stavby nebo části staveb, které nejsou bezbariérově užívané (viz <a href="#p1-4">kap. P1-4</a>)</strong></p>


<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td rowspan="2"><strong>Parametr</strong></td>
<td style="text-align: center;" colspan="4"><strong>Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener">č. 398/2009 Sb.</a></strong></td>
<td style="text-align: center;" colspan="2"><strong>Nařízení <a href="https://www.praha.eu/jnp/cz/o_meste/vyhlasky_a_narizeni/vyhledavani_v_pravnich_predpisech/narizeni_c_10_2016_sb_hl_m_prahy.html" target="_blank" rel="noopener noreferrer">č. 10/2016 Sb. hl. m. Prahy</a></strong></td>
</tr>
<tr>
<td>Průchodná šířka schodišťového ramene</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ 900 mm<sup>4)</sup></td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Průchodná šířka podesty</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ průchodné šířce navazujícího schodišťového ramene</td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Sklon schodišťového ramene</td>
<td style="text-align: center;">α ≤ 28°<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl.2.1.1</td>
<td style="text-align: center;">≤ 35°<sup>5)</sup></td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Počet výšek stupňů v jednom schodišťovém rameni</td>
<td style="text-align: center;">3 ≤ p ≤ 16</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl.2.0.2</td>
<td style="text-align: center;">≤ 18<sup>5)</sup></td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Výška stupně na výstupní čáře</td>
<td style="text-align: center;">≤ 160 mm<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl.2.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Šířka stupně na výstupní čáře</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ 210 mm</td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Šířka stupnice na výstupní čáře</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ 250 mm</td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Poměr mezi výškou stupně h a šířkou stupně b</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">610 mm ≤ 2h + b ≤ 650 mm</td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Průchodná šířka rampy</td>
<td style="text-align: center;">≥ 1500 mm</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≥ 900 mm<sup>5)</sup></td>
<td style="text-align: center;">příloha 1 (6)</td>
</tr>
<tr>
<td>Podélný sklon rampy</td>
<td style="text-align: center;">≤ 1 : 16<sup>2, 3)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 3</a>, čl.2.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Příčný sklon rampy</td>
<td style="text-align: center;">≤ 1 : 100</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 3</a>, čl.2.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td colspan="5"><sup>1)</sup> Neplatí pro stavby bytových domů s výtahem.</td>
</tr>
<tr>
<td colspan="5"><sup>2)</sup> Není-li bezbariérová rampa u změn dokončených staveb delší než 3&nbsp;000 mm, smí mít podélný sklon nejvýše v poměru 1 : 8 (12,5 %); to neplatí pro domy s byty zvláštního určení pro osoby s těžkým pohybovým postižením.</td>
</tr>
<tr>
<td colspan="5"><sup>3)</sup> Bezbariérová rampa delší než 9&nbsp;000 mm musí být přerušena podestou v délce nejméně 1&nbsp;500 mm. Podesty musí mít i kruhová nebo jinak zakřivená bezbariérová rampa. Podesty bezbariérových ramp smí mít sklon pouze v jednom směru a nejvýše v poměru 1 : 50 (2,0 %).</td>
</tr>
<tr>
<td colspan="5"><sup>4)</sup> Konstrukce zábradlí, popř. madel může do průchodné šířky ramene zasahovat nejvýše 100 mm.</td>
</tr>
<tr>
<td colspan="5"><sup>5)</sup> V případě bezbariérově užívaných staveb (viz <a href="#p1-4">kap. P1-4</a> této přílohy) platí požadavek vyhlášky <strong><a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener">č. 398/2009 Sb.</a></strong></td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-2"><strong>P1-2 Požadované rozměry pro schodiště platné na území České republiky (mimo Prahu)</strong></p>



<p class="wp-block-paragraph" id="p1-2-1"><strong>P1-2.1 Rodinné domy a&nbsp;stavby pro rodinnou rekreaci</strong></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Parametr</strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="7"><strong data-rich-text-format-boundary="true">Předpis</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center;" colspan="2"><strong data-rich-text-format-boundary="true">Vyhláška&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener noreferrer">č. 268/2009 Sb.</a></strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">Vyhláška&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a></strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer"><strong data-rich-text-format-boundary="true">ČSN 73 4130</strong></a></td>
<td style="vertical-align: middle; text-align: center;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=70325&amp;cid=5" target="_blank" rel="noopener noreferrer"><strong data-rich-text-format-boundary="true">ČSN 73 4301</strong></a></td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka hlavního schodišťového ramene</td>
<td style="vertical-align: middle; text-align: center;">≥ 900 mm</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_40" target="_blank" rel="noopener noreferrer">§&nbsp;40</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 900 mm<sup>1)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.6.4</td>
<td style="vertical-align: middle; text-align: center;">≥ 900 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 5.3.2.3</td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka vedlejšího schodišťového ramene</td>
<td style="vertical-align: middle; text-align: center;">≥ 750 mm</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_40" target="_blank" rel="noopener noreferrer">§&nbsp;40</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 750 mm<sup>1)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.6.4</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle;">Sklon schodišťového ramene</td>
<td style="vertical-align: middle; text-align: center;">≤ 35°</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_40" target="_blank" rel="noopener noreferrer">§&nbsp;40</a> (3)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≤ 35°<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.1.2</td>
<td style="vertical-align: middle; text-align: center;">≤ 35°</td>
<td style="vertical-align: middle; text-align: center;">čl. 5.3.2.5</td>
</tr>
<tr>
<td style="vertical-align: middle;">Počet výšek stupňů v jednom schodišťovém rameni</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (6)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">3 ≤ <em>p</em> ≤ 18<sup>3)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.4</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupně na výstupní čáře</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 210 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.8</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupnice na výstupní čáře</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 250 mm<sup>4)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.8</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle;">Poměr mezi výškou stupně <em>h</em> a šířkou stupně <em>b</em></td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">2<em>h</em> + <em>b</em> = 630 mm<sup>5)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.6</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">1)</sup>&nbsp;Průchodná šířka ramene se zdvihací plošinou ≥ 550 mm + šířka zdvihací plošiny (čl. 6.6.5). Průchodná šířka mezipodlažní podesty ≥ průchodné šířce navazujícího schodišťového ramene (čl. 7.4.1). Průchodná šířka podlažní podesty ≥ průchodné šířce navazujícího schodišťového ramene +100 až 200 mm (čl. 7.4.2).</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">2)</sup>&nbsp;Nepřesáhne-li konstrukční výška 3&nbsp;000 mm, je možné zvýšit sklon schodišťových ramen až na 41°.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">3)</sup>&nbsp;U dvouramenných a víceramenných schodišť se doporučuje dodržet stejný počet stupňů ve všech ramenech téhož schodiště.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">4)</sup>&nbsp;Stupnice stupňů musí být vodorovné, beze sklonu v příčném i v podélném směru.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">5)</sup>&nbsp;Hodnota 630 mm může být v odůvodněných případech i jiná, nesmí však být mimo interval 600 mm až 650 mm.</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-2-2"><strong>P1-2.2 Byty, obytné části v&nbsp;budovách jiného účelu, nástavby a&nbsp;přístavby budov, jimiž vznikají nové byty, ostatní stavby nebo části staveb, které nejsou bezbariérově užívané (viz. <a href="#p1-4">kap. P1-4</a>)</strong></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Parametr</strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="7"><strong data-rich-text-format-boundary="true">Předpis</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center;" colspan="2"><strong data-rich-text-format-boundary="true">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener noreferrer">č. 268/2009 Sb.</a></strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a></strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer"><strong data-rich-text-format-boundary="true">ČSN 73 4130</strong></a></td>
<td style="vertical-align: middle; text-align: center;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=70325&amp;cid=5" target="_blank" rel="noopener noreferrer"><strong data-rich-text-format-boundary="true">ČSN 73 4301</strong></a></td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka hlavního schodišťového ramene bytového domu</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (8)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 1&nbsp;100 mm<sup>1)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.6.4</td>
<td style="vertical-align: middle; text-align: center;">≥ 1&nbsp;100 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 5.3.2.3</td>
</tr>
<tr>
<td style="vertical-align: middle;">Sklon schodišťového ramene bytového domu s výtahem</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (7)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">25° &lt; <em>α</em> ≤ 35°<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.1.1</td>
<td style="vertical-align: middle; text-align: center;">≤ 35°<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 5.3.2.4</td>
</tr>
<tr>
<td style="vertical-align: middle;">Sklon schodišťového ramene bytového domu bez výtahu</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (7)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">25° &lt; <em>α</em> ≤ 35°<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.1.1</td>
<td style="vertical-align: middle; text-align: center;">≤ 33°</td>
<td style="vertical-align: middle; text-align: center;">čl. 5.3.2.4</td>
</tr>
<tr>
<td style="vertical-align: middle;">Sklon schodišťového ramene na únikové cestě</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (7)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">25° &lt; <em>α</em> ≤ 35°<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 6.1.1</td>
<td style="vertical-align: middle; text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Počet výšek stupňů v jednom schodišťovém rameni</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (6)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">3 ≤ <em>p</em> ≤ 18<sup>3)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.4</td>
<td style="vertical-align: middle; text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupně na výstupní čáře</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 210 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.8</td>
<td style="vertical-align: middle; text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Šířka stupnice na výstupní čáře</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (4)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">≥ 250 mm<sup>4)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.8</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;">Poměr mezi výškou stupně <em>h</em> a šířkou stupně <em>b</em></td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">§&nbsp;22</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">NPD</td>
<td style="vertical-align: middle; text-align: center;">2<em>h</em> + <em>b</em> = 630 mm<sup>5)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 9.1.6</td>
<td style="text-align: center; vertical-align: middle;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">1)</sup> Průchodná šířka ramene se zdvihací plošinou ≥ 550 mm + šířka zdvihací plošiny (čl. 6.6.5). Průchodná šířka mezipodlažní podesty ≥ průchodné šířce navazujícího schodišťového ramene (čl. 7.4.1). Průchodná šířka podlažní podesty ≥ průchodné šířce navazujícího schodišťového ramene +100 až 200 mm (čl. 7.4.2).</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">2)</sup> U schodišť uvnitř bytů s konstrukční výškou menší než 3&nbsp;000 mm a u schodišť do podzemních podlaží a na půdu je možno sklon schodišťových ramen zvýšit až na 41°.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">3)</sup> U dvouramenných a víceramenných schodišť se doporučuje dodržet stejný počet stupňů ve všech ramenech téhož schodiště.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">4)</sup> Stupnice stupňů musí být vodorovné, beze sklonu v příčném i v podélném směru.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="8"><sup data-rich-text-format-boundary="true">5)</sup> Hodnota 630 mm může být v odůvodněných případech i jiná, nesmí však být mimo interval 600 mm až 650 mm.</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-2-3"><strong>P1-2.3 Bezbariérově užívané stavby (viz <a href="#p1-4">kap. P1-4</a>)</strong></p>


<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td rowspan="2"><strong>Parametr</strong></td>
<td style="text-align: center;" colspan="6"><strong>Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a><br /></strong></td>
<td style="text-align: center;" colspan="2"><strong>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener noreferrer">č. 268/2009 Sb.</a><br /></strong></td>
<td style="text-align: center;" colspan="2"><strong><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 4130</a> </strong> <strong>(bezbariérové užívání)</strong></td>
</tr>
<tr>
<td>Průchodná šířka hlavního schodišťového ramene bytového domu</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (8)</td>
<td style="text-align: center;">≥ 1500 mm</td>
<td style="text-align: center;">čl. 6.6.6</td>
</tr>
<tr>
<td>Průchodná šířka schodiště pro hosty (stavby ubytovacích zařízení)</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ 1100 mm</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_43" target="_blank" rel="noopener noreferrer">§ 43</a> (3)</td>
<td style="text-align: center;">≥ 1500 mm</td>
<td style="text-align: center;">čl. 6.6.6</td>
</tr>
<tr>
<td>Průchodná šířka schodiště pro zaměstnance (stavby ubytovacích zařízení)</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≥ 1100 mm</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_43" target="_blank" rel="noopener noreferrer">§ 43</a> (3)</td>
<td style="text-align: center;">≥ 1500 mm</td>
<td style="text-align: center;">čl. 6.6.6</td>
</tr>
<tr>
<td>Sklon schodišťového ramene bytového domu s výtahem</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (7)</td>
<td style="text-align: center;">≤ 28°</td>
<td style="text-align: center;">čl. 6.1.3</td>
</tr>
<tr>
<td>Sklon schodišťového ramene bytového domu bez výtahu</td>
<td style="text-align: center;">≤ 28°<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl. 2.1.1</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (7)</td>
<td style="text-align: center;">≤ 28°</td>
<td style="text-align: center;">čl. 6.1.3</td>
</tr>
<tr>
<td>Sklon schodišťového ramene na únikové cestě</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (7)</td>
<td style="text-align: center;">≤ 28°</td>
<td style="text-align: center;">čl. 6.1.3</td>
</tr>
<tr>
<td>Sklon schodišťového ramene na únikové cestě &#8211; stavby se shromažďovacím prostorem</td>
<td style="text-align: center;">≤ 28°<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl. 2.1.1</td>
<td style="text-align: center;">25° &lt; α ≤ 35°<sup>2)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_41" target="_blank" rel="noopener">§ 41</a> (4)</td>
<td style="text-align: center;">≤ 28°</td>
<td style="text-align: center;">čl. 6.1.3</td>
</tr>
<tr>
<td>Počet výšek stupňů v jednom schodišťovém rameni</td>
<td style="text-align: center;">3 ≤ p ≤ 16<sup>3)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl. 2.0.2</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (6)</td>
<td style="text-align: center;">4 ≤ p ≤ 16<sup>3)</sup></td>
<td style="text-align: center;">čl. 9.1.4</td>
</tr>
<tr>
<td>Výška stupně na výstupní čáře</td>
<td style="text-align: center;">≤ 160 mm<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha 1</a>, čl.2.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≤ 160 mm</td>
<td style="text-align: center;">čl. 9.1.9</td>
</tr>
<tr>
<td>Šířka stupně na výstupní čáře</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (4)</td>
<td style="text-align: center;">≥ 310 mm</td>
<td style="text-align: center;">čl. 9.1.9</td>
</tr>
<tr>
<td>Šířka stupnice na výstupní čáře</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (4)</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Poměr mezi výškou stupně h a šířkou stupně b</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener noreferrer">§ 22</a> (5)</td>
<td style="text-align: center;">2h + b = 630 mm<sup>4)</sup></td>
<td style="text-align: center;">čl. 9.1.6</td>
</tr>
<tr>
<td colspan="7"><sup>1)</sup> Neplatí pro stavby bytových domů s výtahem. Stupnice a podstupnice musí být k sobě kolmé. U změn dokončených staveb v případě šikmé podstupnice může být přesah stupnice nejvýše 25 mm.</td>
</tr>
<tr>
<td colspan="7"><sup>2)</sup> Ramena musí být přímá. Schodiště z tohoto prostoru, s výjimkou schodišť v hledišti, musí mít podestu nejvýše po 15 stupních a podesty před a za dveřmi. Podesta musí být rozšířena tak, aby otevřením dveří nedošlo k zúžení započitatelné šířky únikové cesty.</td>
</tr>
<tr>
<td colspan="7"><sup>3)</sup> U dvouramenných a víceramenných schodišť dodržet stejný počet stupňů ve všech ramenech téhož schodiště. U bezbariérově užívaných schodišť musí být ve všech ramenech téhož schodiště stejný počet stupňů (Vyhláška č. 398/2009 Sb., <a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener">příloha č. 1</a>, čl. 2.0.2).</td>
</tr>
<tr>
<td colspan="7"><sup>4)</sup> Hodnota 630 mm může být v odůvodněných případech i jiná, nesmí však být mimo interval 600 mm až 650 mm.</td>
</tr>
<tr>
<td colspan="7">Schodišťová ramena a ramena šikmých ramp v bezbariérově užívaných stavbách musí být přímá, stupně ve schodišťových ramenech musí být přímé (<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN</a><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer"> 73</a> <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">4130</a>, čl. 6.4.7).</td>
</tr>
<tr>
<td colspan="7">Stupnice stupňů musí být vodorovné, beze sklonu v příčném i v podélném směru (<a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 4130</a>, čl. 9.1.13; Vyhláška č. 268/2009 Sb., <a href="https://e-sbirka.gov.cz/sb/2009/268#par_22" target="_blank" rel="noopener">§ 22</a>, odst.6).</td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-3"><strong>P1-3 Požadované rozměry pro šikmé rampy platné na území České republiky (mimo Prahu)</strong></p>



<p class="wp-block-paragraph" id="p1-3-1"><strong>P1-3.1 Rodinné domy a&nbsp;stavby pro rodinnou rekreaci, byty, obytné části v&nbsp;budovách jiného účelu, nástavby a přístavby budov, jimiž vznikají nové byty, ostatní stavby, které nejsou bezbariérově užívané (viz <a href="#p1-4">kap. P1-4</a>)</strong></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Parametr</strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="4"><strong data-rich-text-format-boundary="true">Předpis</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center;" colspan="2"><strong data-rich-text-format-boundary="true">Vyhláška&nbsp;<a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener noreferrer">č. 268/2009 Sb.</a></strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="2"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer"><strong data-rich-text-format-boundary="true">ČSN 73 4130</strong></a></td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka ramene hlavní, vedlejší a únikové šikmé rampy</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≥ 1&nbsp;500 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 8.2.1</td>
</tr>
<tr>
<td style="vertical-align: middle;">Průchodná šířka ramene pomocných, vyrovnávacích a předložených šikmých ramp</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≥ 900 mm</td>
<td style="vertical-align: middle; text-align: center;">čl. 8.2.2</td>
</tr>
<tr>
<td style="vertical-align: middle;">Délka ramene šikmé rampy</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≤ 9&nbsp;000 mm<sup>1)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 8.1.2</td>
</tr>
<tr>
<td style="vertical-align: middle;">Podélný sklon rampy délky &gt; 3&nbsp;000 mm</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≤ 1 : 12<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 8.1.4</td>
</tr>
<tr>
<td style="vertical-align: middle;">Podélný sklon rampy délky ≤ 3&nbsp;000 mm</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≤ 1: 8 (12,5 %)<sup>2)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 8.1.4</td>
</tr>
<tr>
<td style="vertical-align: middle;">Podélný sklon rampy na únikové cestě</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;">≤ 1 : 8<sup>2,3)</sup></td>
<td style="vertical-align: middle; text-align: center;">čl. 8.1.5</td>
</tr>
<tr>
<td style="vertical-align: middle;">Příčný sklon rampy</td>
<td style="vertical-align: middle; text-align: center;">podle ČSN</td>
<td style="vertical-align: middle; text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§&nbsp;23</a> (5)</td>
<td style="vertical-align: middle; text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="5"><sup>1)</sup> Při větších délkách je třeba přerušit rameno vloženou podestou délky ≥ 1&nbsp;500 mm.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="5"><sup>2)</sup> Podélný sklon ramene má být konstantní po celé jeho délce. Je-li výšková úroveň překonávána jednou šikmou rampou se dvěma, popř. více rameny, má být podélný sklon všech ramen stejný.</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="5"><sup>3)</sup> Výškové rozdíly na únikových cestách z prostorů určených pro shromažďování osob menší než 400 mm musí být vyrovnány rampami s podélným sklonem nejvýše 1: 12 (8,33&nbsp;%).&nbsp;</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-3-2"><strong>P1-3.2 Bezbariérově užívané stavby (viz <a href="#p1-4">kap. P1-4</a>)</strong></p>


<figure class="wp-block-table">
<table>
<tbody>
<tr>
<td rowspan="2"><strong>Parametr</strong></td>
<td style="text-align: center;" colspan="6"><strong>Předpis</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank" rel="noopener noreferrer">č. 268/2009 Sb.</a><br /></strong></td>
<td style="text-align: center;" colspan="2"><strong>Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a><br /></strong></td>
<td style="text-align: center;" colspan="2"><strong data-rich-text-format-boundary="true"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN 73 4130</a></strong>&nbsp;<strong>(bezbariérové užívání)</strong></td>
</tr>
<tr>
<td>Průchodná šířka ramene hlavní, vedlejší a únikové šikmé rampy</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≥ 1&nbsp;500 mm</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≥ 1&nbsp;500 mm</td>
<td style="text-align: center;">čl. 8.2.2</td>
</tr>
<tr>
<td>Průchodná šířka ramene pomocných, vyrovnávacích a předložených šikmých ramp</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≥ 1&nbsp;500 mm</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Délka ramene šikmé rampy</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≤ 9&nbsp;000 mm<sup>1)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.2</td>
<td style="text-align: center;">≤ 9&nbsp;000 mm<sup>1, 2)</sup></td>
<td style="text-align: center;">čl. 8.1.2</td>
</tr>
<tr>
<td>Podélný sklon rampy délky &gt; 3&nbsp;000 mm</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≤ 1 : 16</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≤ 1 : 16 (6,25 %)</td>
<td style="text-align: center;">čl. 8.1.4</td>
</tr>
<tr>
<td>Podélný sklon rampy délky ≤ 3&nbsp;000 mm</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≤ 1 : 16<sup>3)</sup></td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≤ 1 : 16 (6,25 %)</td>
<td style="text-align: center;">čl. 8.1.4</td>
</tr>
<tr>
<td>Podélný sklon rampy na únikové cestě</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≤ 1 : 16</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≤ 1 : 16 (6,25 %)</td>
<td style="text-align: center;">čl. 8.1.4</td>
</tr>
<tr>
<td>Podélný sklon rampy na únikové cestě z prostor určených ke shromažďování překonávající výškový rozdíl ≤ 400 mm</td>
<td style="text-align: center;">≤ 1: 12</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_41" target="_blank" rel="noopener noreferrer">§ 41</a> (3)</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;">≤ 1 : 12</td>
<td style="text-align: center;">čl. 8.1.5</td>
</tr>
<tr>
<td>Podélný sklon rampy délky ≤ 3&nbsp;000 mm v hledištích</td>
<td style="text-align: center;">≤ 1: 8</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_41" target="_blank" rel="noopener noreferrer">§ 41</a> (6)</td>
<td style="text-align: center;" colspan="2">NPD</td>
<td style="text-align: center;" colspan="2">NPD</td>
</tr>
<tr>
<td>Příčný sklon rampy</td>
<td style="text-align: center;">podle ČSN</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/268#par_23" target="_blank" rel="noopener noreferrer">§ 23</a> (5)</td>
<td style="text-align: center;">≤ 1 : 100</td>
<td style="text-align: center;"><a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 3</a>, čl.2.1.1</td>
<td style="text-align: center;">≤ 1 : 100</td>
<td style="text-align: center;">čl. 8.1.6</td>
</tr>
<tr>
<td colspan="7"><sup>1)</sup> Rampa delší než 9&nbsp;000 mm musí být přerušena podestou v délce nejméně 1500 mm. Podesty musí mít i kruhová nebo jinak zakřivená rampa. Podesty bezbariérových ramp smí mít sklon pouze v jednom směru a nejvýše v poměru 1 : 50 (2,0 %).</td>
</tr>
<tr>
<td colspan="7"><sup>2)</sup> Podélný sklon ramene rampy má být konstantní po celé jeho délce. Je-li výšková úroveň překonávána jednou šikmou rampou se dvěma, popř. více rameny, má být podélný sklon všech ramen stejný.</td>
</tr>
<tr>
<td colspan="7"><sup>3)</sup> Není-li bezbariérová rampa u změn dokončených staveb delší než 3&nbsp;000 mm, smí mít podélný sklon nejvýše v poměru 1 : 8 (12,5 %); to neplatí pro domy s byty zvláštního určení pro osoby s těžkým pohybovým postižením.</td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p1-4"><strong><strong>P1-4 BEZBARIÉROVĚ UŽÍVANÉ STAVBY</strong></strong></p>



<ul class="wp-block-list is-style-nerazeny-list-bez-odrazek">
<li>(1) Požadavky vyhlášky&nbsp;č. 398/2009 Sb. (<a href="https://e-sbirka.gov.cz/sb/2009/398#par_2" target="_blank" rel="noreferrer noopener">§ 2</a>, odst. 1)&nbsp;platí pro stavby:
<ul class="wp-block-list">
<li>a) pozemních komunikací a veřejného prostranství,</li>



<li>b) občanského vybavení v částech určených pro užívání veřejností,</li>



<li>c) společných prostor a domovního vybavení bytového domu obsahujícího více než 3 byty, upravitelného bytu nebo bytu zvláštního určení,</li>



<li>d) pro výkon práce celkově 25 a více osob, pokud provoz v těchto stavbách umožňuje zaměstnávat osoby se zdravotním postižením, nebo stavby pro výkon práce osob s těžkým zdravotním postižením.<br></li>
</ul>
</li>



<li>(2) Stavbou občanského vybavení podle vyhlášky č. 398/2009 Sb. (<a href="https://e-sbirka.gov.cz/sb/2009/398#par_6" target="_blank" rel="noreferrer noopener">§ 6</a>, odst.1) se rozumí:
<ul class="wp-block-list">
<li>a) stavba pro veřejnou správu, soudy, státní zastupitelství, policii, obviněné a odsouzené,</li>



<li>b) stavba pro sdělovací prostředky,</li>



<li>c) stavba pro obchod a služby,</li>



<li>d) stavba pro ochranu obyvatelstva,</li>



<li>e) stavba pro sport,</li>



<li>f) školy, předškolní a školská zařízení,</li>



<li>g) stavba pro kulturu a duchovní osvětu,</li>



<li>h) stavba pro zdravotnictví a sociální služby,</li>



<li>i) budova pro veřejnou dopravu,</li>



<li>j) stavba ubytovacího zařízení pro cestovní ruch s celoročním i sezónním provozem pro více než 20 osob.</li>
</ul>
</li>
</ul>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading"><strong>P1-5 CITOVANÉ NORMY A&nbsp;PŘEDPISY</strong></h3>



<p class="wp-block-paragraph" id="literatura-10">[10] Vyhláška MMR&nbsp;<a rel="noreferrer noopener" href="https://e-sbirka.gov.cz/sb/2009/268?zalozka=text" target="_blank">č. 268/2009 Sb.</a>, o technických požadavcích na stavby, ve znění pozdějších předpisů</p>



<p class="wp-block-paragraph" id="literatura-11">[11] Vyhláška MMR&nbsp;<a rel="noreferrer noopener" href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank">č. 398/2009 Sb.</a>, o obecných technických požadavcích zabezpečujících bezbariérové užívání staveb</p>



<p class="wp-block-paragraph" id="literatura-12">[12] Nařízení&nbsp;<a rel="noreferrer noopener" href="https://www.praha.eu/jnp/cz/o_meste/vyhlasky_a_narizeni/vyhledavani_v_pravnich_predpisech/narizeni_c_10_2016_sb_hl_m_prahy.html" target="_blank">č. 10/2016 Sb. hl. m. Prahy</a>, kterým se stanovují obecné požadavky na využívání území a technické požadavky stavby v hlavním městě Praze (pražské stavební předpisy) ve znění nařízení č. 14/2018 Sb. HMP</p>



<p class="wp-block-paragraph" id="literatura-13">[13]&nbsp;<a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=85172&amp;cid=5" target="_blank">ČSN 73 4130</a>:2010&nbsp;Schodiště a šikmé rampy – Základní požadavky, ÚNMZ, Praha 2010</p>



<p class="wp-block-paragraph" id="literatura-14">[14]&nbsp;<a rel="noreferrer noopener" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=70325&amp;cid=5" target="_blank">ČSN 73 4301</a>:2004&nbsp;Obytné budovy, ÚNMZ, Praha 2004</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="priloha-2">PŘÍLOHA 2 – BEZPEČNOST POHYBU PO&nbsp;SCHODIŠTI A&nbsp;ŠIKMÉ RAMPĚ</h3>



<ul class="wp-block-list is-style-nerazeny-list-bez-odrazek">
<li>(1) Geometrie schodišť a šikmých ramp by měly být navrženy s ohledem na jejich bezpečnost. Důležité je zvolit takové rozměry a povrchovou úpravu, aby byly dodrženy technické požadavky na výstavbu a hrozilo co nejmenší riziko úrazu (podklouznutí, zakopnutí apod.).<br></li>



<li>(2) Hlavní faktory, které mohou ovlivnit bezpečnost pohybu po schodišti, jsou následující:
<ul class="wp-block-list">
<li>a) sklon schodišťového ramene nebo ramene šikmé rampy;</li>



<li>b) protiskluzná úprava povrchu schodišťových stupňů nebo šikmé rampy;</li>



<li>c) minimální rozměry a tvar hrany čel schodišťových stupňů nebo šikmé rampy;</li>



<li>d) geometrická přesnost dokončeného schodišťového ramene nebo ramene šikmé rampy.<br></li>
</ul>
</li>



<li>(3) Další faktory bezpečnosti pohybu po schodišti:
<ul class="wp-block-list">
<li>a) z hlediska rizika pádu je důležité kontrastní označení nástupního a výstupního stupně každého schodišťového ramene nebo vyrovnávacích stupňů</li>



<li>b) z hlediska rizika úrazu hlavy je důležité zabezpečení prostoru pod schodištěm nebo rampou.<br></li>
</ul>
</li>



<li>(4) Požadavky na sklon, protiskluznou úpravu a minimální rozměry, kontrastní označení stupnic a zabezpečení prostoru pod schodištěm jsou dány technickými normami a/nebo závaznými předpisy.<br></li>



<li>(5) Doporučené odchylky geometrické přesnosti jsou stanoveny v rámci tohoto standardu.</li>
</ul>



<p class="wp-block-paragraph"><br><strong>Riziko pádu v&nbsp;závislosti na rozměrech schodišťových stupňů</strong>&nbsp;</p>



<p class="wp-block-paragraph">(1) Rozměry (výška a šířka) schodišťových stupňů můžou výrazně ovlivnit bezpečnost pohybu po schodišti. V rámci schodišťového ramene se budou vždy vyskytovat určité odchylky výšky a šířky schodišťových stupňů, vyplývající z možností použité technologie výroby.</p>



<p class="wp-block-paragraph">(2) Rozdíly rozměrů mezi sousedními schodišťovými stupni mohou ovlivnit délku části chodidla, která přesahuje přes hranu schodu. Změna délky části chodidla, která se bude pohybovat na hraně schodu, bude ovlivněna změnou výšky a šířky schodišťových stupňů jdoucích za sebou a bude mnohem významnější při sestupu po schodišťovém rameni v případě, že po stupni s větší šířkou bude ihned následovat stupeň s menší šířkou.</p>


<div class="wp-block-image">
<figure class="aligncenter size-large"><img loading="lazy" decoding="async" width="319" height="165" src="https://profesis.ckait.cz/wp-content/uploads/2020/05/ts02-pril2-obr1.gif" alt="" class="wp-image-1112"/></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 1</em>&nbsp;&nbsp;Poloha chodidla na hraně schodu (uvažováno pro velikost obuvi č. 9)</p>



<p class="wp-block-paragraph">(3) Z pohledu bezpečnosti je tedy lepší navrhnout schodiště s větší šířkou schodišťových stupňů (hrozí menší riziko podklouznutí) a menší výškou schodišťových stupňů (hrozí menší riziko zakopnutí).</p>



<p class="wp-block-paragraph"><em>Tab. 6.1</em>&nbsp;&nbsp;Riziko pádu na schodišťovém rameni se 14 stupni za předpokladu nulové odchylky geometrické přesnosti <a href="#literatura-17">[17]</a></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Šířka stupně</strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="4"><strong data-rich-text-format-boundary="true">Předpokládaný čas mezi jednotlivými zraněními (pády) při</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">5 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">25 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">100 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">2000 průchodech za den</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;">225 mm</td>
<td style="vertical-align: middle; text-align: center;">4 roky</td>
<td style="vertical-align: middle; text-align: center;">298 dnů</td>
<td style="vertical-align: middle; text-align: center;">75 dnů</td>
<td style="vertical-align: middle; text-align: center;">4 dny</td>
</tr>
<tr>
<td style="vertical-align: middle;">250 mm</td>
<td style="vertical-align: middle; text-align: center;">11 let</td>
<td style="vertical-align: middle; text-align: center;">2 roky</td>
<td style="vertical-align: middle; text-align: center;">198 dnů</td>
<td style="vertical-align: middle; text-align: center;">10 dnů</td>
</tr>
<tr>
<td style="vertical-align: middle;">275 mm</td>
<td style="vertical-align: middle; text-align: center;">145 let</td>
<td style="vertical-align: middle; text-align: center;">29 let</td>
<td style="vertical-align: middle; text-align: center;">7 let</td>
<td style="vertical-align: middle; text-align: center;">133 dnů</td>
</tr>
<tr>
<td style="vertical-align: middle;">≥ 300 mm</td>
<td style="vertical-align: middle; text-align: center;">&gt; 1000 let</td>
<td style="vertical-align: middle; text-align: center;">&gt; 1000 let</td>
<td style="vertical-align: middle; text-align: center;">&gt; 1000 let</td>
<td style="vertical-align: middle; text-align: center;">73 let</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><em>Tab. 6.2</em>&nbsp;&nbsp;Riziko pádu na schodišťovém rameni se 14 stupni za předpokladu, že jeden schod je o 5 mm užší <a href="#literatura-17">[17]</a></p>


<table style="border-collapse: collapse; width: 100%;" cellpadding="5px" border="1">
<tbody>
<tr>
<td style="vertical-align: middle;" rowspan="2"><strong data-rich-text-format-boundary="true">Šířka stupně</strong></td>
<td style="vertical-align: middle; text-align: center;" colspan="4"><strong data-rich-text-format-boundary="true">Předpokládaný čas mezi jednotlivými zraněními (pády) při</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">5 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">25 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">100 průchodech za den</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">2000 průchodech za den</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;">225 mm</td>
<td style="vertical-align: middle; text-align: center;">3 roky</td>
<td style="vertical-align: middle; text-align: center;">239 dnů</td>
<td style="vertical-align: middle; text-align: center;">60 dnů</td>
<td style="vertical-align: middle; text-align: center;">3 dny</td>
</tr>
<tr>
<td style="vertical-align: middle;">250 mm</td>
<td style="vertical-align: middle; text-align: center;">9 let</td>
<td style="vertical-align: middle; text-align: center;">2 roky</td>
<td style="vertical-align: middle; text-align: center;">156 dnů</td>
<td style="vertical-align: middle; text-align: center;">8 dnů</td>
</tr>
<tr>
<td style="vertical-align: middle;">275 mm</td>
<td style="vertical-align: middle; text-align: center;">109 let</td>
<td style="vertical-align: middle; text-align: center;">22 let</td>
<td style="vertical-align: middle; text-align: center;">5 let</td>
<td style="vertical-align: middle; text-align: center;">99 dnů</td>
</tr>
<tr>
<td style="vertical-align: middle;">≥ 300 mm</td>
<td style="vertical-align: middle; text-align: center;">&gt; 1000 let</td>
<td style="vertical-align: middle; text-align: center;">&gt; 1000 let</td>
<td style="vertical-align: middle; text-align: center;">990 let</td>
<td style="vertical-align: middle; text-align: center;">50 let</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(4) Z výše uvedených tabulek vyplývá, že například na schodišti, které má šířku schodišťových stupňů 250 mm a denně po něm projde cca 100 lidí, hrozí riziko pádu každých 198 dní v případě, že jsou stupně bez odchylek geometrické přesnosti, a riziko pádu každých 156 dnů v případě, že by jeden stupeň byl užší o cca 5 mm. Zároveň lze konstatovat, že hrozí výrazně vyšší riziko zranění na schodišti, které má šířku schodišťového stupně do 275 mm než na schodišti, které bude mít schodišťové stupně širší.</p>



<p class="wp-block-paragraph">(5) Na bezpečnost pohybu po schodišti má tedy výrazně větší vliv základní (navrhovaný) rozměr schodišťových stupňů než odchylky geometrické přesnosti. Čím větší šířku schodišťový stupeň bude mít, tím menší hrozí riziko zranění při pohybu po schodišti.</p>



<p class="wp-block-paragraph">(6) Doporučené rozměry výšky a šířky schodišťového stupně vychází z normových požadavků na poměr výšky a šířky schodišťového stupně, minimálního, respektive maximálního sklonu schodišťového ramene a výše uvedených rizikových faktorů.</p>



<p class="wp-block-paragraph"><em>Tab. 6.3</em>&nbsp;&nbsp;Doporučené rozměry schodišťových stupňů [rozměry v mm]</p>


<table style="width: 100%; border-collapse: collapse;" border="1" cellpadding="5px">
<tbody>
<tr>
<td style="vertical-align: middle;"><strong data-rich-text-format-boundary="true">Typ schodiště / Objekt</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">Šířka schodu(<em>b</em>)</strong></td>
<td style="vertical-align: middle; text-align: center;"><strong data-rich-text-format-boundary="true">Výška schodu(<em>h</em>)</strong></td>
</tr>
<tr>
<td style="vertical-align: middle;">Hlavní a přiměřeně úniková a ostatní schodiště<sup>1)</sup> / Bezbariérově užívané stavby</td>
<td style="vertical-align: middle; text-align: center;">≥ 310</td>
<td style="vertical-align: middle; text-align: center;">≤ 160</td>
</tr>
<tr>
<td style="vertical-align: middle;">Hlavní a úniková schodiště / Bytové domy, prostory pro shromažďování, únikové cesty</td>
<td style="vertical-align: middle; text-align: center;">≥ 300</td>
<td style="vertical-align: middle; text-align: center;">≤ 180</td>
</tr>
<tr>
<td style="vertical-align: middle;">Hlavní schodiště / Rodinné domy a stavby pro rodinnou rekreaci</td>
<td style="vertical-align: middle; text-align: center;">≥ 275</td>
<td style="vertical-align: middle; text-align: center;">≤ 190</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="3"><sup data-rich-text-format-boundary="true">1)</sup> Vyhláška <a href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank" rel="noopener noreferrer">č. 398/2009 Sb.</a>, <a href="https://e-sbirka.gov.cz/sb/2009/398#prilohy" target="_blank" rel="noopener noreferrer">příloha č. 1</a>, čl. 2.0.1</td>
</tr>
<tr>
<td style="vertical-align: middle;" colspan="3">Vedlejší schodiště mohou mít jiné rozměry (šířku, výšku) schodišťových stupňů za předpokladu, že budou dodrženy předepsané limitní parametry (minimální, maximální sklon schodišťového ramene, minimální šířka stupně a poměr mezi výškou a šířkou schodišťového stupně).</td>
</tr>
</tbody>
</table>


<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph">(7) Na bezpečnost pohybu po schodišti mají vliv také odchylky geometrické přesnosti výšky a šířky dokončených schodišťových stupňů. Mezní odchylky rozměrů schodišťových stupňů, uvedené v tomto dokumentu, jsou doporučeny na základě hodnot zjištěných měřením schodišť dokončených staveb. Z měření vyplývá, že odchylku ±5 mm je možné dosáhnout v 95 % měření. Z výzkumů bezpečnosti pohybu po schodišti vyplývá, že tato odchylka rozměru schodišťového stupně nezvyšuje výrazně riziko úrazu.</p>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph" id="p2-1"><strong>P2-1 LITERATURA, CITOVANÉ NORMY A&nbsp;PŘEDPISY</strong></p>



<p class="wp-block-paragraph" id="literatura-15">[15] BS 5395-1 &#8211; Stairs. Code of practice for the design of stairs with straight flights and winders, BSI 2010</p>



<p class="wp-block-paragraph" id="literatura-16">[16] DIN 18 065 &#8211; Gebäudetreppen &#8211; Begriffe, Messregeln, Hauptmaße. Deutsches Institut für Normung e. V, 2011.</p>



<p class="wp-block-paragraph" id="literatura-17">[17] Information paper IP 15/03 &#8211; Proprietary nosing for non-domestic stairs, BRE 2003</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="9">PŘÍLOHA 3 – POSOUZENÍ NÁVRHU SCHODIŠTĚ Z&nbsp;HLEDISKA ÚRAZOVOSTI</h3>



<p class="wp-block-paragraph">Pomocný výpočet pro posouzení návrhu schodiště z&nbsp;hlediska úrazovosti.</p>



<div class="wp-block-file"><a id="wp-block-file--media-6f23c786-99da-4b1a-b587-721655baf5a5" href="https://profesis.ckait.cz/wp-content/uploads/2020/06/ts-02-priloha-3.xlsx">Soubor ve formátu Excel</a><a href="https://profesis.ckait.cz/wp-content/uploads/2020/06/ts-02-priloha-3.xlsx" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-6f23c786-99da-4b1a-b587-721655baf5a5">Stáhnout</a></div>



<p class="wp-block-paragraph"><br></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TS 03 &#8211; Návrh skleněných prvků ve stavebnictví (Technický standard ČKAIT)</title>
		<link>https://profesis.ckait.cz/dokumenty-ckait/ts-03/</link>
		
		<dc:creator><![CDATA[CKAIT Profesis Admin]]></dc:creator>
		<pubDate>Thu, 31 Mar 2022 15:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://profesis.ckait.cz/?post_type=dokumenty&#038;p=12314</guid>

					<description><![CDATA[Stanoví obecné zásady, postupy a doporučení k navrhování skleněných prvků ve stavebnictví. Upozorňuje na základní oblasti, které je nutné zohlednit při návrhu skleněných prvků pro správnou funkci budoucí stavební konstrukce, obsahující skleněné prvky a pro zajištění jejího ekonomicky efektivního a udržitelného provozu. Verze 2: TS 03-2024]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>Autoři:</strong> <a href="/autori/franek-ondrej/">Ing. Ondřej Franek</a>, <a href="/autori/klecka-jan/">Ing. Jan Klečka</a></p>



<p class="wp-block-paragraph"><strong>Odborní konzultanti:</strong> doc. Ing. Martina Eliášová, CSc., Alena Daňhelovská, Ing. David Kelich, Ing. Roman Šnajdr, Ing. Miroslav Špaček, Ing. Milan Zápotocký</p>



<p class="wp-block-paragraph"><strong>Odborné posouzení:</strong> Technická komise ČKAIT</p>



<p class="wp-block-paragraph"><strong>Stav:</strong> verze 2, vydání duben 2024</p>



<p class="wp-block-paragraph"><strong>Účinnost:</strong> od 1. 7. 2024</p>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong>JEDNOTLIVÁ VYDÁNÍ:</strong></p>



<p class="wp-block-paragraph"><strong>Účinnost verze 1:</strong> od 1. 7. 2022 do 30. 6. 2024</p>



<div class="wp-block-file"><a id="wp-block-file--media-dbb74d51-2f81-49c5-8e5d-469dda0282b6" href="https://profesis.ckait.cz/wp-content/uploads/2022/04/ts-03-v-2022.pdf" target="_blank" rel="noreferrer noopener">TS 03-2022 ČKAIT ve formátu PDF ke stažení</a><a href="https://profesis.ckait.cz/wp-content/uploads/2022/04/ts-03-v-2022.pdf" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-dbb74d51-2f81-49c5-8e5d-469dda0282b6">Stáhnout</a></div>



<p class="wp-block-paragraph"><strong>Účinnost verze 2:</strong> od 1. 7. 2024</p>



<div class="wp-block-file"><a id="wp-block-file--media-72640fc1-1371-427e-a0b4-ea5a08cc10d1" href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024.pdf">TS 03-2024 ČKAIT ve formátu PDF ke stažení</a><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024.pdf" class="wp-block-file__button wp-element-button" download aria-describedby="wp-block-file--media-72640fc1-1371-427e-a0b4-ea5a08cc10d1">Stáhnout</a></div>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong><a href="/upozorneni-k-textum">Upozornění k&nbsp;textu</a></strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide"/>



<p class="wp-block-paragraph"><strong>PŘEDMLUVA</strong></p>



<p class="wp-block-paragraph">Pro správnou funkci stavební konstrukce, obsahující skleněné prvky a zajištění jejího ekonomicky efektivního a udržitelného provozu, je nezbytné již ve fázi návrhu zohlednit řadu faktorů mající vliv na skleněné prvky, jež se mohou vyskytnout v době výstavby či v době provozu budoucí stavby. Rizika spjatá s použitím skleněných prvků lze významně snížit již ve fázi návrhu, kdy vzniká celkové koncepční řešení navrhované konstrukce. Tento technický standard řeší základní oblasti, které je nutné zohlednit při návrhu skleněných prvků ve stavebnictví a na základě dosavadních poznatků z oboru stanovuje obecné zásady, postupy a doporučení k navrhování skleněných prvků.</p>



<p class="wp-block-paragraph">Respektování zásad uvedených v tomto standardu významně přispívá ke snížení rizika ohrožení zdraví a života osob a zvířat z důvodu kolapsu skleněných prvků, dále přispívá k ekonomicky efektivnímu provozu z důvodu minimalizace poruch plynoucích z nevhodného koncepčního řešení.</p>



<hr class="wp-block-coblocks-dynamic-separator is-style-fullwidth" style="height:1px"/>



<p class="wp-block-paragraph"><strong>Technický standard ČKAIT</strong> je doporučený dokument obsahující technické informace, které mají být respektovány, a instrukce popisující činnost, která se má provést. Stanovuje technické požadavky, které má stavební konstrukce, proces, nebo služba splňovat. Technický standard může také uvádět postupy, jejichž pomocí lze určit, zda jsou dané požadavky splněny.</p>



<p class="wp-block-paragraph">Technické standardy ČKAIT nejsou obecně závazné, jsou to však odborně kvalifikované předpisy, na které se mohou odkazovat smluvní strany při specifikaci předmětu smlouvy a podmínek jejího plnění nebo státní autorita ve svých obecně závazných předpisech.</p>



<p class="wp-block-paragraph"><strong>OBSAH</strong></p>


<figure class="wp-block-table">
<table style="border-style: hidden;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="border-style: hidden;" colspan="2"><a href="#predmluva">Předmluva</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right; width: 15px;"><strong>1</strong></td>
<td style="border-style: hidden;"><a href="#1"><strong>Předmět</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>2</strong></td>
<td style="border-style: hidden;"><a href="#2"><strong>Termíny a definice</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.1</td>
<td style="border-style: hidden;"><a href="#2-1">Skleněný prvek</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.2</td>
<td style="border-style: hidden;"><a href="#2-2">Svislé zasklení</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.3</td>
<td style="border-style: hidden;"><a href="#2-3">Šikmé zasklení</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.4</td>
<td style="border-style: hidden;"><a href="#2-4">Vodorovné zasklení</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.5</td>
<td style="border-style: hidden;"><a href="#2-5">Lepené zasklení</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.6</td>
<td style="border-style: hidden;"><a href="#2-6">Jednovrstvé sklo</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.7</td>
<td style="border-style: hidden;"><a href="#2-7">Vrstvené sklo</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.8</td>
<td style="border-style: hidden;"><a href="#2-8">Izolační sklo</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.9</td>
<td style="border-style: hidden;"><a href="#2-9">Chlazené sklo</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.10</td>
<td style="border-style: hidden;"><a href="#2-10">Zasklení s ochrannou funkcí (security glass)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.11</td>
<td style="border-style: hidden;"><a href="#2-11">Zasklení bezpečnostní (safety glass)</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.12</td>
<td style="border-style: hidden;"><a href="#2-12">PVB</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.13</td>
<td style="border-style: hidden;"><a href="#2-13">EVA</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.14</td>
<td style="border-style: hidden;"><a href="#2-14">Lonoplast</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">2.15</td>
<td style="border-style: hidden;"><a href="#2-15">TPU</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>3</strong></td>
<td style="border-style: hidden;"><a href="#3"><strong>Požadavky na skleněné prvky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">3.1</td>
<td style="border-style: hidden;"><a href="#3-1">Mechanická odolnost a stabilita</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">3.2</td>
<td style="border-style: hidden;"><a href="#3-2">Bezpečnost provozu</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">3.3</td>
<td style="border-style: hidden;"><a href="#3-3">Materiálová kompatibilita</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>4</strong></td>
<td style="border-style: hidden;"><a href="#4"><strong>Statické a dynamické požadavky na skleněné prvky</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.1</td>
<td style="border-style: hidden;"><a href="#4-1">Obecné požadavky</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.2</td>
<td style="border-style: hidden;"><a href="#4-2">Zatížení</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">4.3</td>
<td style="border-style: hidden;"><a href="#4-3">Zvláštní požadavky</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>5</strong></td>
<td style="border-style: hidden;"><a href="#5"><strong>Návrh</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.1</td>
<td style="border-style: hidden;"><a href="#5-1">Vodorovné a šikmé skleněné prvky</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.2</td>
<td style="border-style: hidden;"><a href="#5-2">Svislé a šikmé skleněné prvky</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.3</td>
<td style="border-style: hidden;"><a href="#5-3">Speciální aplikace</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.4</td>
<td style="border-style: hidden;"><a href="#5-4">Vandalismus</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.5</td>
<td style="border-style: hidden;"><a href="#5-5">Teplotní šok</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">5.6</td>
<td style="border-style: hidden;"><a href="#5-6">Ostatní</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>6</strong></td>
<td style="border-style: hidden;"><a href="#6"><strong>Dokumentace skleněných prvků</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.1</td>
<td style="border-style: hidden;"><a href="#6-1">Požadavky na projektovou dokumentaci</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.2</td>
<td style="border-style: hidden;"><a href="#6-2">Požadavky na dokumentaci zajišťovanou zhotovitelem</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;">6.3</td>
<td style="border-style: hidden;"><a href="#6-3">Provozní řády, plán kontrol a údržby</a></td>
</tr>
<tr>
<td style="border-style: hidden; text-align: right;"><strong>7</strong></td>
<td style="border-style: hidden;"><a href="#7"><strong>Literatura, citované předpisy a normy</strong></a></td>
</tr>
<tr>
<td style="border-style: hidden;" colspan="2"><a href="#priloha-1">Příloha 1 – Požadovaný charakter lomu skla pro konkrétní aplikace</a></td>
</tr>
</tbody>
</table>
</figure>


<p class="wp-block-paragraph"><br></p>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide"/>



<h3 class="wp-block-heading" id="1">1 PŘEDMĚT</h3>



<p class="wp-block-paragraph">Technický standard stanovuje požadavky na návrh skleněných prvků pozemních staveb ve vnitřním i vnějším prostředí. Pro ostatní oblasti stavebnictví se má při návrhu skleněných konstrukcí přihlížet k požadavkům tohoto standardu. Tento dokument se zabývá požadavky na návrh svislých, šikmých a vodorovných skleněných prvků a jejich umístění ve stavbě z pohledu aktivní a pasivní bezpečnosti, ochrany osob, zdraví a majetku a vazby na vnitřní prostředí budov.</p>



<p class="wp-block-paragraph">Tento standard platí přiměřeně i pro údržbu, výměny a opravy prvků, rekonstrukce a dostavby stávajících staveb. Pro historické objekty nebo stavby chráněné památkovým úřadem platí přiměřeně statusu daného objektu.</p>



<p class="wp-block-paragraph">Technický standard se vztahuje na: zasklení otvorových výplní, zasklení lehkých obvodových plášťů, skleněné obkladové prvky fasád včetně skleněných lamel, prosklené světlíky, prosklené střechy a přístřešky, které jsou nedílnou součástí stavby, podlahy se skleněnými prvky, sklo pochozí pro údržbu a sklo pochozí pro veřejnost, zábradlí celoskleněné či se skleněnými prvky a nenosné skleněné příčky.</p>



<p class="wp-block-paragraph">Technický standard se nevztahuje na sklo dlouhodobě ponořené ve vodě, skleněné prvky u mostních a dopravních konstrukcí, fotovoltaické panely a atypické či dočasné skleněné prvky (např. umělecké instalace apod.).</p>



<p class="wp-block-paragraph">Technický standard nestanovuje metodiku statického a dynamického výpočtového posouzení skleněných prvků, statické a dynamické výpočtové posouzení se provádí podle samostatných technických předpisů. Tento standard se nezabývá použitím skleněných prvků s požadavky na požární odolnost. Pro prvky se specifickými nároky plynoucími z konkrétního požárně bezpečnostního řešení stavby nebo odvodu tepla a kouře má být standard aplikován v přiměřeném rozsahu.</p>



<p class="wp-block-paragraph">Tento dokument se nezabývá uváděním stavebních výrobků na trh.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2">2 TERMÍNY A DEFINICE</h3>



<p class="wp-block-paragraph">Pro účely tohoto standardu platí termíny a definice uvedené v ČSN&nbsp;EN&nbsp;572, ČSN&nbsp;EN&nbsp;1279, ČSN&nbsp;EN&nbsp;1863, ČSN&nbsp;EN&nbsp;12150, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503929&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;12488</a>, ČSN&nbsp;EN&nbsp;ISO 12543, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503693&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;13119</a>, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=500794&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;14019</a>, ČSN&nbsp;EN&nbsp;14178, ČSN&nbsp;EN&nbsp;14179, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=74871&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;14449</a>, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=511483&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;16612</a>, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=511193&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;16613</a>, ČSN&nbsp;73&nbsp;1901, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=15810&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;73&nbsp;3440</a>, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank">ČSN&nbsp;74&nbsp;3305</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503984&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;6077</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=31219&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;6210</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=31236&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;6550</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=504184&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;7250</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=504195&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;7251</a>, a dále uvedené termíny a definice.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-1">2.1 SKLENĚNÝ PRVEK</h3>



<p class="wp-block-paragraph">Skleněná či prosklená část konstrukce umístěna uvnitř či vně budovy.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-2">2.2 SVISLÉ ZASKLENÍ</h3>



<p class="wp-block-paragraph">Část zasklení, jehož sklon je vychýlen od svislice o 15° včetně a méně.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-3">2.3 ŠIKMÉ ZASKLENÍ</h3>



<p class="wp-block-paragraph">Část zasklení, jehož sklon je vychýlen od svislice o více než 15° a méně než 85°.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-4">2.4 VODOROVNÉ ZASKLENÍ</h3>



<p class="wp-block-paragraph">Část zasklení, jehož sklon je vychýlen od svislice o 85° včetně a více.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-5">2.5 LEPENÉ ZASKLENÍ</h3>



<p class="wp-block-paragraph">Definuje <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503693&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;13119</a>, sklo primárně přichyceno po obvodu strukturálním tmelem, případně doplněno příchytným systémem, dříve označováno také jako strukturální zasklení.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-6">2.6 JEDNOVRSTVÉ SKLO</h3>



<p class="wp-block-paragraph">Jednotka složená z jedné monolitické tabule skla, bez vnitřní dutiny.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-7">2.7 VRSTVENÉ SKLO</h3>



<p class="wp-block-paragraph">Jednotka složená z více monolitických tabulí skla, které jsou vzájemně spojeny jednou nebo více mezivrstvami, definuje <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90442&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;ISO 12543-1</a> a na trh je uváděno podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=74871&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;14449</a>.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-8">2.8 IZOLAČNÍ SKLO</h3>



<p class="wp-block-paragraph">Jednotka složená ze dvou nebo více tabulí skla, s meziskelní dutinou, jež je hermeticky utěsněná k zajištění lepší tepelné a zvukové izolace, definuje <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503693&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;13119</a> a na trh je uváděno podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=506964&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;1279-5</a>. Může být použit termín izolační zasklení.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-9">2.9 CHLAZENÉ SKLO</h3>



<p class="wp-block-paragraph">Ploché, průhledné, čiré nebo zabarvené sodnovápenatokřemičité sklo, definuje <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=502414&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;572-1+A1</a>. Jedná se např. o sklo float, sklo ploché tažené, sklo vzorované.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-10">2.10 ZASKLENÍ S OCHRANNOU FUNKCÍ (SECURITY GLASS)</h3>



<p class="wp-block-paragraph">Zasklení se zvýšenou odolností proti náhodnému vandalismu nebo plánovanému útoku, určené k ochraně osob a majetku proti vedenému útoku z opačné strany skla bezpečného prostoru. Složeno ze skla nebo ze skla a plastů, jednovrstvé nebo vícevrstvé konstrukce, přičemž jednotlivé vrstvy mají stejnou tloušťku v celé ploše výrobku. Kategorizováno podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=60147&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;356</a>, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=59664&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;1063</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90560&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;13541</a>.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-11">2.11 ZASKLENÍ BEZPEČNOSTNÍ (SAFETY GLASS)</h3>



<p class="wp-block-paragraph">Zasklení se specifickou vlastností, která zvyšuje jeho odolnost proti rozbití, či s vlastností, která zvyšuje jeho neškodnost v případě překročení mezního stavu použitelnosti a mezního stavu únosnosti. Obvykle je charakter lomu bezpečnostního zasklení kategorizováno jako B a C podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a>. Bezpečnostní sklo splňuje požadavky ČSN&nbsp;EN&nbsp;ISO 12543, ČSN&nbsp;EN&nbsp;12150, <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503536&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;14179-1</a>, <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=75162&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;14321-1</a> nebo <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=94976&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;15683-1</a>.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-12">2.12 PVB</h3>



<p class="wp-block-paragraph">Materiál používaný pro mezilehlé fólie vrstveného bezpečnostního skla na bázi polyvinylbutyralu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-13">2.13 EVA</h3>



<p class="wp-block-paragraph">Materiál používaný pro mezilehlé fólie vrstveného bezpečnostního skla na bázi ethylenvinylacetátu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-14">2.14 IONOPLAST</h3>



<p class="wp-block-paragraph">Materiál používaný pro mezilehlé fólie vrstveného bezpečnostního skla na bázi ionomeru.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="2-15">2.15 TPU</h3>



<p class="wp-block-paragraph">Materiál používaný pro mezilehlé fólie vrstveného bezpečnostního skla na bázi termoplastického polyuretanu.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3">3 POŽADAVKY NA SKLENĚNÉ PRVKY</h3>



<h3 class="wp-block-heading" id="3-1">3.1 MECHANICKÁ ODOLNOST A STABILITA</h3>



<p class="wp-block-paragraph" id="3-1-1"><strong>3.1.1</strong><br>Skleněné prvky musí být navrženy v souladu s technickými normami tak, aby účinky návrhového zatížení a předpokládané nepříznivé vlivy prostředí, kterým jsou vystaveny během výstavby a užívání při řádně prováděné běžné údržbě, plnily svou funkci po celou dobu návrhové životnosti konstrukce.<sup><a href="#poznamka-1">1)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-1"><strong>Poznámka<sup>1)</sup>:</strong><br>Běžnou údržbou se rozumí mytí objektu, provádění vizuálních kontrol a oprava či výměna prvků za pomoci stabilních nebo mobilních mechanismů.</p>



<p class="wp-block-paragraph" id="3-1-2"><strong>3.1.2</strong><br>Skleněné prvky ve vnějším i vnitřním prostředí musí být navrženy tak, aby odolaly předpokládaným teplotním zatížením, které mohou nastat během výstavby a užívání. Zejména se jedná o předpokládané zatížení prouděním, sáláním a vedením tepla či kombinací uvedeného.</p>



<p class="wp-block-paragraph" id="3-1-3"><strong>3.1.3</strong><br>Během návrhové životnosti skleněného prvku nesmí dojít k náhlé ztrátě stability skleněného prvku či jeho části při působení stanovených návrhových podmínek.</p>



<p class="wp-block-paragraph" id="3-1-4"><strong>3.1.4</strong><br>Kapitola 4 uvádí další statické a dynamické požadavky na skleněné prvky.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3-2">3.2 BEZPEČNOST PROVOZU</h3>



<p class="wp-block-paragraph" id="3-2-1"><strong>3.2.1</strong><br>V případě samovolné poruchy skleněného prvku musí být zachována strukturální integrita celého systému a nesmí dojít k ohrožení života a zdraví osob a zvířat a k ohrožení majetku.<sup><a href="#poznamka-2">2)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-2"><strong>Poznámka<sup>2)</sup>:</strong><br>U skleněného prvku existuje vždy riziko samovolné poruchy zejména vlivem přípustných výrobních imperfekcí. To platí především u skleněných prvků z tepelně tvrzeného bezpečnostního skla a prohřívaného tepelně tvrzeného bezpečnostního skla z důvodu rizika inkluze NiS, přičemž u prohřívaného tepelně tvrzeného bezpečnostního skla definovaného podle ČSN&nbsp;EN&nbsp;14179 je riziko výrazně nižší, ale není vyloučeno. Přípustné výrobní imperfekce společně s kombinací dalších vlivů v působení v čase mohou zapříčinit náhlý kolaps skleněného prvku.</p>



<p class="wp-block-paragraph" id="3-2-2"><strong>3.2.2</strong><br>Je doporučeno, aby všechny lepené prvky měly lokální mechanické jištění pro případ selhání lepeného spoje.</p>



<p class="wp-block-paragraph" id="3-2-3"><strong>3.2.3</strong><br>Skleněné prvky mají být navrženy tak, aby porucha libovolné jednotlivé součásti nemohla vést k progresivnímu selhání sousedních skleněných prvků.</p>



<p class="wp-block-paragraph" id="3-2-4"><strong>3.2.4</strong><br>Je doporučeno zpracovat analýzu rizik zohledňující vliv případné poruchy navržených skleněných prvků na ohrožení života a zdraví osob a zvířat a k ohrožení majetku. Zvláštní důraz má být kladen na umístění skleněných prvků navrhovaných nad prostory přístupných uživatelům.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="3-3">3.3 MATERIÁLOVÁ KOMPATIBILITA</h3>



<p class="wp-block-paragraph" id="3-3-1"><strong>3.3.1</strong><br>Materiálové řešení skleněných prvků, jejich uchycení i dílčí části, musí být zvoleno tak, aby nemohlo dojít k negativnímu ovlivnění z důvodu vzájemné nesnášenlivosti materiálů, a to i s ohledem na navržené konstrukční tmely a fólie.</p>



<p class="wp-block-paragraph" id="3-3-2"><strong>3.3.2</strong><br>Materiálové řešení skleněných prvků, jejich uchycení i dílčí části, musí být zvoleno tak, aby po dobu své návrhové životnosti a při běžné údržbě, odolaly všem běžným předvídatelným vlivům prostředí, a to zejména UV záření, kyselým dešťům či chemismu prostředí.<sup><a href="#poznamka-3">3)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-3"><strong>Poznámka<sup>3)</sup>:</strong><br>V návrhu by měla být stanovena a zohledněna maximální funkční teplota všech skleněných prvků včetně jejich dílčích částí a řešeno riziko porušení spojů s ohledem na rozdílné chování různých materiálů při změnách teplot.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4">4 STATICKÉ A DYNAMICKÉ POŽADAVKY NA SKLENĚNÉ PRVKY</h3>



<h3 class="wp-block-heading" id="4-1">4.1 OBECNÉ POŽADAVKY</h3>



<p class="wp-block-paragraph" id="4-1-1"><strong>4.1.1</strong><br>Všechny skleněné prvky musí být staticky a dynamicky posouzeny na účinky všech předpokládaných zatížení.</p>



<p class="wp-block-paragraph" id="4-1-2"><strong>4.1.2</strong><br>Statický i dynamický posudek musí posoudit osoba oprávněná, podle zvláštního právního předpisu.<sup><a href="#poznamka-4">4)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-4"><strong>Poznámka<sup>4)</sup>:</strong><br>Zákon <a rel="noopener noreferrer" href="https://e-sbirka.gov.cz/sb/1992/360?zalozka=text" target="_blank">č. 360/1992 Sb.</a></p>



<p class="wp-block-paragraph" id="4-1-3"><strong>4.1.3</strong><br>Materiálové charakteristiky skleněného prvku musí být stanoveny v projektové dokumentaci. Při dimenzování skleněného prvku musí být známa veškerá návrhová a předpokládaná zatížení.</p>



<p class="wp-block-paragraph" id="4-1-4"><strong>4.1.4</strong><br>Skleněné prvky s požadavky na mechanickou odolnost (např. zábradelní výplň, podlaha) musí mít výpočtem stanovenou pevnost při příčném zatížení skleněných tabulí, a to podle technických norem.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4-2">4.2 ZATÍŽENÍ</h3>



<p class="wp-block-paragraph" id="4-2-1"><strong>4.2.1</strong><br>Zatížení skleněných prvků se stanoví podle ČSN&nbsp;EN&nbsp;1991-1.</p>



<p class="wp-block-paragraph" id="4-2-2"><strong>4.2.2</strong><br>Je-li právními nebo technickými předpisy specifikována minimální požadovaná odolnost skleněného prvku vůči konkrétním mimořádným zatížením, musí takovým zatížením prvek odolat. Mimořádná zatížení, zejména nárazy a výbuchy, se stanoví podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=79645&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1991-1-7</a>.</p>



<p class="wp-block-paragraph" id="4-2-3"><strong>4.2.3</strong><br>Má-li být skleněný prvek navržen na další speciální zatížení, je nutné takové zatížení specifikovat projektem pro stavební povolení.</p>



<p class="wp-block-paragraph" id="4-2-4"><strong>4.2.4</strong><br>V návrhových hodnotách zatížení musí být uvažován předpokládaný způsob údržby, zejména pohyb horolezců po svislých nebo šikmých plochách, pohyb osob po vodorovných a šikmých plochách a mobilní lávky zavěšené na úrovni horní hrany budovy.</p>



<p class="wp-block-paragraph" id="4-2-5"><strong>4.2.5</strong><br>Pokud se mimořádně může vyskytnout zatížení nedefinované v předchozích odstavcích a skleněný prvek nemá předpoklad takovým zatížením odolat, je doporučeno ochránit skleněný prvek jiným způsobem a posoudit následky kolapsu skleněných prvků s ohledem na bezpečnost osob.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="4-3">4.3 ZVLÁŠTNÍ POŽADAVKY</h3>



<p class="wp-block-paragraph" id="4-3-1"><strong>4.3.1</strong><br>Skleněný prvek musí být navržen tak, aby odolal všem předpokládaným zatížením teplotou, zejména od slunečního záření, ale i od jiných zdrojů tepla. Musí být posouzeny především takové účinky, které způsobují nerovnoměrné zahřátí skleněného prvku. Podle předpokládaného teplotního zatížení je nutné volit materiálové řešení skla podle <a href="#tab-1">tab. 1</a>.<sup><a href="#poznamka-5">5)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-5"><strong>Poznámka<sup>5)</sup>:</strong><br>Působení teplotního zatížení na skleněné prvky může vést k trvalému poškození prvku z důvodu teplotního šoku. Rizikové jsou zejména rozdíly teplot v rámci jednoho skleněného prvku.</p>



<p class="wp-block-paragraph" id="tab-1"><em>Tab. 1</em> Maximálně přípustný teplotní rozdíl v rámci skleněného prvku pro jednovrstvé sklo čiré<sup><a href="#poznamka-6">6)</a></sup></p>



<figure class="wp-block-table">
    <table>
        <tbody>
        <tr>
            <td style="background-color: #cccccc;">Druh skla</td>
            <td style="text-align: center; background-color: #cccccc;">Definuje</td>
            <td style="text-align: center; background-color: #cccccc;">Maximální přípustný rozdíl teploty</td>
        </tr>
        <tr>
            <td>Chlazené</td>
            <td style="text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=502414&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;572-1+A1</a></td>
            <td style="text-align: center;">40 K</td>
        </tr>
        <tr>
            <td>Tepelně zpevněné sklo</td>
            <td style="text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90679&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1863-1</a></td>
            <td style="text-align: center;">100 K</td>
        </tr>
        <tr>
            <td>Tepelně tvrzené sklo</td>
            <td style="text-align: center;"><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=509508&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12150-1+A1</a></td>
            <td style="text-align: center;">200 K</td>
        </tr>
        </tbody>
    </table>
</figure>



<p class="wp-block-paragraph"></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-6"><strong>Poznámka<sup>6)</sup>:</strong><br>Charakteristické hodnoty uvedené v <a href="#tab-1">tab. 1</a> jsou pouze orientační. Hodnoty nezohledňují způsob uložení, polohu skla a jeho opracování, typ rámu či typ zatížení. Charakteristické hodnoty maximálního přípustného teplotního rozdílu pro jiné druhy skla (vzorované sklo, vzorované sklo s drátěnou vložkou, sklo s potiskem, sklo pískované, sklo ovlivněné úpravami interiéru apod.) se mohou lišit od hodnot uvedených v <a href="#tab-1">tab. 1</a>.</p>



<p class="wp-block-paragraph" id="4-3-2"><strong>4.3.2</strong><br>Při návrhu skleněných prvků z vrstveného bezpečnostního skla, které jsou zatíženy krátkodobě či dlouhodobě provozní teplotou nižší než 0 °C nebo vyšší než 40 °C, je nutné zohlednit riziko snížení tuhosti (smykového modulu pružnosti) mezilehlé fólie, především s ohledem na statickou, respektive dynamickou funkci prvku.</p>



<p class="wp-block-paragraph" id="4-3-3"><strong>4.3.3</strong><br>Při návrhu skleněných prvků z vrstveného bezpečnostního skla, které dlouhodobě přenáší statické zatížení od dalších konstrukcí nebo zatížení užitné, je nutné zohlednit riziko snížení tuhosti (smykového modulu pružnosti) mezilehlé fólie z důvodu působení kombinace dlouhodobého statického zatížení a zatížení teplotou.</p>



<p class="wp-block-paragraph" id="4-3-4"><strong>4.3.4</strong><br>Vždy je nutné posoudit dilatační podmínky skleněných prvků. Vypočtenou dilataci skla je doporučeno zvětšit minimálně o 30 %. Pro stanovení rozměrů obvodové spáry je nutné zohlednit i výrobní tolerance skleněných tabulí.</p>



<p class="wp-block-paragraph" id="4-3-5"><strong>4.3.5</strong><br>Při návrhu skleněných prvků s nosnou sekundární konstrukcí je nutné zohlednit rozdílnou teplotní roztažnost a rozdílnou tepelnou setrvačnost jednotlivých konstrukčních materiálů. V místě uchycení skleněného prvku musí být zohledněn vliv napětí vyvolaný rozdílným teplotním zatížením v rámci jednotlivých materiálů.<sup><a href="#poznamka-7">7)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-7"><strong>Poznámka<sup>7)</sup>:</strong><br>Namáhání skleněných prvků vyvolané tepelnou setrvačností jednotlivých materiálů je pozorovatelné například u celoprosklené fasády, kterou vynáší z interiérové strany ocelová konstrukce pomocí terčů.  V ranních hodinách slunečného dne se nejdříve významně zahřívá povrch neseného skleněného prvku, přičemž nosná sekundární konstrukce má stále naakumulovaný chlad získaný z noci. Další významné namáhání je ve večerních hodinách, kdy vnější vzduch po západu slunce významně ochlazuje povrch neseného skleněného prvku na fasádě, přičemž nosná sekundární konstrukce má stále naakumulované teplo získané během dne. U zmíněného příkladu mohou být jednotlivé materiály zatíženy značně rozdílnou teplotou a v rámci nosné sekundární konstrukce a nenosného skleněného prvku není dilatační pohyb shodný.</p>



<p class="wp-block-paragraph" id="4-3-6"><strong>4.3.6</strong><br>Při návrhu izolačního skla se má přihlížet k průhybu skla vyvolaného změnami atmosférického tlaku, změnami teplot a působením větru. Je-li požadován konkrétní přípustný průhyb, musí být v projektu pro stavební povolení specifikován.</p>



<p class="wp-block-paragraph" id="4-3-7"><strong>4.3.7</strong><br>Při návrhu skleněných prvků se má přihlížet k plánované životnosti stavby. Určení plánované životnosti skleněných prvků a jejich komponent se stanoví podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=95827&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;ISO&nbsp;15686-1</a> a v projektové dokumentaci.</p>



<p class="wp-block-paragraph" id="4-3-8"><strong>4.3.8</strong><br>Není-li možné postupovat při posuzování podle technických předpisů z důvodu jejich neexistence, nebo jedná-li se o atypickou konstrukci či dosud netestovanou sestavu standardní produktové řady, je nutné posoudit návrh experimentálně, formou výpočtů a testů v akreditované zkušebně. Takové posouzení musí schválit stavebník a připustit stavební úřad.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5">5 NÁVRH</h3>



<h3 class="wp-block-heading" id="5-1">5.1 VODOROVNÉ A ŠIKMÉ SKLENĚNÉ PRVKY</h3>



<p class="wp-block-paragraph" id="5-1-1"><strong>5.1.1</strong><br>Podélně či bodově uložené vodorovné a šikmé zasklení musí být navrženo z vrstveného bezpečnostního skla, jež je složeno ze skla chlazeného nebo ze skla tepelně zpevněného, či jejich kombinací. Použití tepelně tvrzeného bezpečnostního skla a prohřívaného tepelně tvrzeného bezpečnostního skla je přípustné pouze v kombinaci s tepelně zpevněným sklem nebo sklem chlazeným v rámci jedné tabule vrstveného bezpečnostního skla. Použití vrstveného skla složeného pouze z tepelně tvrzeného bezpečnostního skla nebo prohřívaného tepelně tvrzeného bezpečnostního skla může být také použito, bude-li prokázáno, že v případě kolapsu všech vrstev skla zároveň, se porušené skleněné souvrství nevysmekne jako celek z uložení a nedojde k jeho zřícení.</p>



<p class="wp-block-paragraph" id="5-1-2"><strong>5.1.2</strong><br>Použití jednovrstvého skla pro vodorovné a šikmé zasklení není přípustné. Použití jednovrstvého skla s drátěnou vložkou pro vodorovné a šikmé zasklení není přípustné nad veřejnými a nad shromažďovacími prostorami.</p>



<p class="wp-block-paragraph" id="5-1-3"><strong>5.1.3</strong><br>Použití vrstveného skla pro vodorovné a šikmé zasklení musí mít odpovídající kategorii odolnosti pro navržený provoz podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=60147&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;356</a>, kategorie odolnosti musí být minimálně P2A nebo vyšší.</p>



<p class="wp-block-paragraph" id="5-1-4"><strong>5.1.4</strong><br>Skleněný prvek má být navržen tak, aby během své návrhové životnosti při uvážení všech návrhových zatížení nepřesáhl průhyb L/150, kde L je vzdálenost mezi podporami prvku, jak znázorňuje <a href="#obr-1">obr. 1</a>. Při vícestranném uložení je L délkou nejkratší strany. Jsou-li požadovány přísnější hodnoty maximálního přípustného průhybu či limitní absolutní hodnota průhybu, musí to být specifikováno v projektu pro stavební povolení.</p>



<p class="wp-block-paragraph"></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-1"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-001.png"><img loading="lazy" decoding="async" width="910" height="231" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-001.png" alt="" class="wp-image-12962" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-001.png 910w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-001-150x38.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-001-768x195.png 768w" sizes="(max-width: 910px) 100vw, 910px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 1</em> Maximální průhyb skleněného prvku</p>



<p class="wp-block-paragraph" id="5-1-5"><strong>5.1.5</strong><br>U podélně podepřených skleněných prvků je doporučeno mít rozpětí mezi podporami maximálně 1,2 m.</p>



<p class="wp-block-paragraph" id="5-1-6"><strong>5.1.6</strong><br>Návrh vodorovného a šikmého zasklení a jeho uchycení musí být uzpůsoben tak, aby v případě porušení skla nedošlo k pádu celého skleněného prvku, jeho úlomků a dílčích částí, včetně částí sloužících k uchycení skleněného prvku.<sup><a href="#poznamka-8">8)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-8"><strong>Poznámka<sup>8)</sup>:</strong><br>K porušení skla může dojít vlivem mimořádného nepředvídatelného zatížení (např. krupobití s výjimečnou intenzitou, pád břemene z vyšší polohy, pád břemene při extrémním větru, dopravní nehoda). Taková rizika je doporučeno řešit individuálně pro konkrétní aplikace s vyhodnocením analýzy rizik, a to již ve fázi návrhu skleněných prvků, ve stupni Dokumentace pro stavební povolení. Zvláštní důraz má být kladen při použití skleněných prvků nad plochami s pohybem osob a nad shromažďovacími prostory. U vodorovného a šikmého izolačního skla musí spodní tabule splňovat požadavky uvedené v <a href="#5-1-1">odst. 5.1.1</a> až <a href="#5-1-6">5.1.6</a>. Pro horní tabuli izolačního skla, zatíženou klimatickými vlivy, se doporučuje použití tepelně zpevněného a tepelně tvrzeného či prohřívaného tepelně tvrzeného bezpečnostního skla.</p>



<p class="wp-block-paragraph" id="5-1-7"><strong>5.1.7 Nepochozí střešní plochy, světlíky, přístřešky</strong></p>



<p class="wp-block-paragraph" id="5-1-7-1">5.1.7.1<br>Při návrhu střech, světlíků a přístřešků se skleněnými prvky se postupuje podle ČSN&nbsp;73&nbsp;1901.<sup><a href="#poznamka-9">9)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-9"><strong>Poznámka<sup>9)</sup>:</strong><br>Střechy se skleněnými prvky mají být řešeny v připravované ČSN&nbsp;73&nbsp;1901-4. U střešních ploch, světlíků a přístřešků se skleněnými prvky je zvýšené riziko pádu sněhu a ledu z důvodu nižšího součinitele smykového tření oproti tradičním materiálům. Tato vlastnost má být zohledněna zejména při navrhování skleněných prvků nad přístupnými pochozími plochami a komunikacemi.</p>



<p class="wp-block-paragraph" id="5-1-7-2">5.1.7.2<br>Prosklené střešní plochy, světlíky a přístřešky, u kterých se předpokládá zatížení klimatickými vlivy, musí být spolehlivě odvodněny a minimální navržený sklon má být 10° v příčném nebo podélném směru, jak je znázorněno na <a href="#obr-2">obr. 2</a>.<sup><a href="#poznamka-10">10)</a></sup></p>



<p class="wp-block-paragraph"></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-2"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-002.png"><img loading="lazy" decoding="async" width="700" height="610" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-002.png" alt="" class="wp-image-12963" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-002.png 700w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-002-150x131.png 150w" sizes="(max-width: 700px) 100vw, 700px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 2</em> Minimální navržený sklon v příčném nebo podélném směru</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-10"><strong>Poznámka<sup>10)</sup>:</strong><br>Sklon 10° zohledňuje toleranci 1,5° pro provádění, za minimální sklon při provádění se uvažuje 8,5°. Sklon skla 8,5° a více zajišťuje spolehlivé odvádění vody a zároveň je minimalizována tvorba nečistot na skle. Při menších sklonech se zvyšuje míra znečištění skla během provozu a je vyžadováno častější čištění takového prvku.</p>



<p class="wp-block-paragraph" id="5-1-7-3">5.1.7.3<br>Je-li navržen přístřešek ze skla tam, kde se předpokládá pád sněhu a ledu ze stávajících výše položených částí konstrukce, např. ze střechy, musí na to být přístřešek ze skla již v návrhu dimenzován.</p>



<p class="wp-block-paragraph" id="5-1-8"><strong>5.1.8 Podlahy a pochozí vnější plochy</strong></p>



<p class="wp-block-paragraph">5.1.8.1<br>Podlahy a pochozí vnější plochy, u nichž nášlapná vrstva sestává ze skleněných prvků, musí být navrženy tak, aby splňovaly předepsané vlastnosti protiskluznosti podle zvláštních předpisů.<sup><a href="#poznamka-11">11)</a></sup> Při stanovení protiskluzných vlastností má být zohledněn vliv prostředí.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-11"><strong>Poznámka<sup>11)</sup>:</strong><br><a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=89997&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;74&nbsp;4505</a>.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-2">5.2 SVISLÉ A ŠIKMÉ SKLENĚNÉ PRVKY</h3>



<p class="wp-block-paragraph" id="5-2-1"><strong>5.2.1</strong><br>Je-li horní hrana skleněného prvku výše než 4 m nad terénem a jsou-li v přilehlém prostoru ve vzdálenosti menší než 2,5 m veřejně přístupné pochozí plochy nebo komunikace, nebo je-li horní hrana skleněného prvku výše než 30 m nad terénem a jsou-li v přilehlém prostoru ve vzdálenosti <em>h</em>/10 veřejně přístupné pochozí plochy nebo komunikace, kde <em>h</em> je výška horní hrany skleněného prvku nad terénem, má být ze strany volného terénu svislé a šikmé zasklení navrženo z vrstveného bezpečnostního skla. Vrstvené bezpečnostní sklo nesmí být složeno pouze z tabulí tepelně tvrzeného a prohřívaného tepelně tvrzeného skla, nebude-li prokázáno, že se v případě kolapsu všech dílčích tabulí vrstveného zasklení, porušené skleněné souvrství nevysmekne jako celek z uložení a nedojde k jeho zřícení.</p>



<p class="wp-block-paragraph" id="5-2-2"><strong>5.2.2</strong><br>Není-li pro aplikace uvedené v <a href="#5-2-1">odstavci 5.2.1</a> možné z technických důvodů použít vrstvené bezpečnostní sklo, má být použito jednovrstvé tepelně zpevněné sklo, které má být čtyřstranně uložené<sup>.<a href="#poznamka-12">12)</a></sup> <sup><a href="#poznamka-13">13)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-12"><strong>Poznámka<sup>12)</sup>:</strong><br>Použití vrstveného bezpečnostního skla je obtížně aplikovatelné zejména v případě tónovaných skel, např. v pozicích svislých obkladů v místech parapetů, kdy v letních měsících dochází k poškození skla z důvodu nadlimitního zahřívání mezilehlých vrstev.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-13"><strong>Poznámka<sup>13)</sup>:</strong><br>U tepelně zpevněných skel hrozí v případě kolapsu riziko vytvoření úlomku ve tvaru „ostrova“ ve středové části prvku a může dojít k jeho vypadnutí. Takové riziko se zvyšuje se zvětšujícím se formátem skla. Uvedené riziko má být v návrhu zohledněno.</p>



<p class="wp-block-paragraph" id="5-2-3"><strong>5.2.3</strong><br><a href="#5-2-1">Odst. 5.2.1</a> se nevztahuje na případy, kdy je provedeno konstrukční opatření, kdy každá hrana skleněného prvku je v kolmé vzdálenosti od okraje do volného prostoru minimálně 2 m a výška od úrovně konstrukce, jež dělí sklo od volného prostoru, je k hornímu okraji hrany skla menší než 4 m. <a href="#5-2-1">Odst. 5.2.1</a> se nevztahuje na zasklení svislých okenních otvorových výplní, u nichž je plocha tabule skla menší než 2 m<sup>2</sup>. <a href="#5-2-1">Odst. 5.2.1</a> se nevztahuje na případy, kdy je navrženo ochranné zařízení, které zabrání ohrožení života a zdraví osob a zvířat padajícími úlomky v případě kolapsu skleněných prvků.</p>



<p class="wp-block-paragraph" id="5-2-4"><strong>5.2.4</strong><br>Pro aplikace neuvedené v <a href="#5-2-1">odst. 5.2.1</a> může být použito i prohřívané tepelně tvrzené sklo podle výrobkové normy <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=74870&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;EN&nbsp;14179-2</a>. Použití tepelně tvrzeného skla bez zkoušky Heat Soak Test není přípustné.</p>



<p class="wp-block-paragraph" id="5-2-5"><strong>5.2.5</strong><br>Vnější svislé a šikmé obkladové prvky fasád mají odpovídat <a href="#5-2-1">odst. 5.2.1</a> až <a href="#5-2-4">5.2.4</a>.</p>



<p class="wp-block-paragraph" id="5-2-6"><strong>5.2.6</strong><br>U rekonstrukcí stávajících staveb, kde není možné postupovat podle <a href="#5-2-1">odst. 5.2.1</a>, a kde je nad veřejně přístupnými plochami nebo komunikacemi jednovrstvé sklo chlazené, tepelně tvrzené bezpečnostní sklo nebo prohřívané tepelně tvrzené bezpečnostní sklo, má být navrženo ochranné zařízení či konstrukční opatření, které zabrání ohrožení života a zdraví osob a zvířat padajícími úlomky v případě kolapsu skleněných prvků.<sup><a href="#poznamka-14">14)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-14"><strong>Poznámka<sup>14)</sup>:</strong><br>Vztahuje se zejména na svislé a šikmé skleněné obkladové prvky fasád, na dělicí příčky balkónů, na celoskleněné a částečně prosklené zábradelní výplně, na vnější tabule izolačního zasklení otvorových výplní apod.</p>



<p class="wp-block-paragraph" id="5-2-7"><strong>5.2.7 Zábradlí</strong></p>



<p class="wp-block-paragraph" id="5-2-7-1"><strong>5.2.7.1</strong><br>Zábradlí musí být navrženo v souladu s <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;74&nbsp;3305</a>.</p>



<p class="wp-block-paragraph" id="5-2-7-2"><strong>5.2.7.2</strong><br>Celoskleněné samonosné zábradlí a prosklené zábradelní výplně nesmí být navrženy z jednovrstvého skla: skla chlazeného, tepelně zpevněného skla, tepelně tvrzeného bezpečnostního skla, a prohřívaného tepelně tvrzeného bezpečnostního skla.<sup><a href="#poznamka-15">15)</a></sup></p>



<p class="wp-block-paragraph" id="5-2-7-3"><strong>5.2.7.3</strong><br>Při návrhu celoskleněného samonosného zábradlí z vrstveného bezpečnostního skla složeného pouze z tepelně tvrzeného bezpečnostního skla, respektive z prohřívaného tepelně tvrzeného bezpečnostního skla v kombinaci s mezilehlou fólií PVB nebo EVA, má být v návrhu zohledněno riziko vypadnutí skleněné výplně z uložení v případě současného kolapsu všech dílčích tabulí skla v rámci tabule vrstveného bezpečnostního skla. To může nastat v případě nevhodného bodového kotvení, kde nastává při současném kolapsu všech tabulí významné riziko protržení mezilehlé fólie a následný pád skleněného prvku.<sup><a href="#poznamka-15">15)</a> <a href="#poznamka-16">16)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-15"><strong>Poznámka<sup>15)</sup>:</strong><br>Jednovrstvé sklo má nedostatečnou zbytkovou únosnost. Jednoduché vrstvené sklo z tepelně tvrzeného bezpečnostního skla v kombinaci s fólií PVB či EVA, zejména při uložení typu E podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank">ČSN&nbsp;74&nbsp;3305</a>, má minimální zbytkovou únosnost. Zbytková únosnost neboli pokritické chování (post-failure behaviour) je vlastnost prvku plnit strukturální integritu systému i při jeho porušení vlivem přetížení (poškození), vizuálně patrném. Prvek již není schopen přenášet další zatížení. Příkladem zbytkové únosnosti je porušení skleněného prvku z vrstveného bezpečnostního skla složeného ze skel chlazených, od zatížení překračující mezní stav použitelnosti, kdy vznikne viditelné poškození – lom charakteru B, přičemž prvek jako celek nezkolabuje a nadále setrvává z větší míry na svém stanovišti.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-16"><strong>Poznámka<sup>16)</sup>:</strong><br>Riziko současného kolapsu všech dílčích tabulí ve vrstveném bezpečnostním skle složeného pouze z&nbsp;tabulí tepelně tvrzeného bezpečnostního skla, resp. prohřívaného tepelně tvrzeného bezpečnostního skla, se významně zvyšuje při absenci ochrany hran skleněných tabulí, které jsou vůči mechanickému poškození náchylné.</p>



<p class="wp-block-paragraph" id="5-2-7-4"><strong>5.2.7.4</strong><br>Horní hrana celoskleněného zábradlí má být chráněna proti mechanickému poškození a proti působení klimatických vlivů. Pro ochranu horní hrany se doporučuje použití průběžného ochranného profilu pro účinnější redistribuci statického zatížení, jak znázorňuje <a href="#obr-3">obr. 3</a>.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-3"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-003.png"><img loading="lazy" decoding="async" width="410" height="285" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-003.png" alt="" class="wp-image-12964" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-003.png 410w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-003-150x104.png 150w" sizes="(max-width: 410px) 100vw, 410px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 3</em> &nbsp;Ochrana hrany zábradlí</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading">5.3 SPECIÁLNÍ APLIKACE</h3>



<p class="wp-block-paragraph" id="5-3-1"><strong>5.3.1</strong><br>Prosklené otvorové výplně a prosklené příčky v zařízeních a provozovnách pro výchovu a vzdělávání dětí a mladistvých specifikovaných zvláštním právním předpisem<sup><a href="#poznamka-17">17)</a></sup>, dále staveb a prostor ve stavbách s požadavky na bezbariérové užívání staveb specifikovaných zvláštním právním předpisem<sup><a href="#poznamka-17">17)</a></sup>, mají být navrženy z bezpečnostního skla s charakterem lomu typu B podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a>.<sup><a href="#poznamka-18">18)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-17"><strong>Poznámka<sup>17)</sup>:</strong><br>Vyhláška <a rel="noopener noreferrer" href="https://e-sbirka.gov.cz/sb/2005/410?zalozka=text" target="_blank">č. 410/2005 Sb.</a>; Vyhláška <a rel="noopener noreferrer" href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank">č. 398/2009 Sb.</a></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-18"><strong>Poznámka<sup>18)</sup>:</strong><br>Požadavek se nevztahuje na prostory definované v <a href="#5-3-7">odst. 5.3.7</a> a <a href="#5-3-8">5.3.8</a>.</p>



<p class="wp-block-paragraph" id="5-3-2"><strong>5.3.2</strong><br>Místnosti určené pro tělovýchovu, pro sportovní a pohybové aktivity, musí mít ke směru rizika mechanickým poškozením navrženy veškeré vodorovné i svislé skleněné prvky včetně otvorových výplní z bezpečnostního skla s charakterem lomu typu B podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a>.<sup><a href="#poznamka-18">18)</a></sup> Zejména v místnostech pro tělovýchovu a pro sportovní a pohybové aktivity je doporučeno chránit skleněné prvky další mechanickou ochranou, jako je například ochranná mříž či síť.</p>



<p class="wp-block-paragraph" id="5-3-3"><strong>5.3.3</strong><br>Při použití vrstveného bezpečnostního skla složené pouze z tepelně tvrzeného bezpečnostního skla či prohřívaného tepelně tvrzeného bezpečnostního skla v prostorách definovaných v&nbsp;<a href="#5-3-1">odst.&nbsp;5.3.1</a> a <a href="#5-3-2">5.3.2</a>, má být v návrhu zohledněno riziko vypadnutí skleněné výplně z&nbsp;uložení v&nbsp;případě současného kolapsu všech dílčích tabulí skla v rámci tabule vrstveného bezpečnostního skla. Má být navrženo takové uchycení, které spolehlivě zabrání vypadnutí skla při současném kolapsu všech dílčích tabulí vrstveného skla.<sup><a href="#poznamka-15">15)</a> <a href="#poznamka-16">16)</a></sup></p>



<p class="wp-block-paragraph" id="5-3-4"><strong>5.3.4</strong><br>U úprav stávajících staveb je přípustné použití dodatečně lepených fólií na jednovrstvé sklo, pokud bude prokázáno rázovou zkouškou podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a> charakter lomu typu B a zároveň bude-li doloženo, že životnost adheze fólie je při působení všech návrhových vlivů minimálně stejná jako návrhová životnost samotného skleněného prvku.<sup><a href="#poznamka-19">19)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-19"><strong>Poznámka<sup>19)</sup>:</strong><br>Dodatečně lepené fólie mohou zhoršit protipožární vlastnosti skleněných prvků, to musí být posouzeno v požárně-bezpečnostním posouzení. Fólie má být aplikována vždy až k hraně skleněného prvku, respektive skleněné tabule. Před aplikací fólie má být zohledněno a posouzeno riziko teplotního šoku.</p>



<p class="wp-block-paragraph" id="5-3-5"><strong>5.3.5</strong><br>Při návrhu prosklených příček a otvorových výplní musí být zohledněno maximální podélné zkrácení skleněného prvku vlivem příčného průhybu od návrhového zatížení, v souvislosti&nbsp;s&nbsp;minimální hloubkou uložení skleněného prvku a rizika jeho vypadnutí z kluzného uložení, jak je znázorněno na <a href="#obr-4">obr. 4</a>.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-4"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-004.png"><img loading="lazy" decoding="async" width="564" height="514" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-004.png" alt="" class="wp-image-12965" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-004.png 564w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-004-150x137.png 150w" sizes="(max-width: 564px) 100vw, 564px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 4&nbsp; </em>Znázornění příčného průhybu od návrhového zatížení a riziko podélného zkrácení</p>



<p class="wp-block-paragraph" id="5-3-6"><strong>5.3.6</strong><br>Předpokládá-li se v budově pohyb osob na invalidním vozíku, vstup osob s kočárky, nebo pohyb s manipulačními vozíky a úklidovými vozíky, doporučuje se, aby spodní hrana zasklení byla nejméně ve výšce 400 mm nad podlahou nebo bylo zasklení chráněno mechanickou zábranou. Samotné bezpečnostní zasklení nemá být považováno za mechanickou zábranu.</p>



<p class="wp-block-paragraph" id="5-3-7"><strong>5.3.7</strong><br>V bazénových halách, místnostech s vířivkami, šatnách a hygienických zařízeních bazénových provozů a provozů wellness, vyjma prohříváren, musí být skleněné prvky navrženy z bezpečnostního skla s charakterem lomu typu B nebo C podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a>. V těchto prostorech není přípustné použití dodatečně lepené fólie na jednovrstvé sklo pro zajištění charakteru lomu typu B. Při návrhu se má zohlednit úroveň hygroskopie mezilehlé vrstvy s ohledem na riziko delaminace během provozu.<sup><a href="#poznamka-20">20)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-20"><strong>Poznámka<sup>20)</sup>:</strong><br>Mezilehlé vrstvy (fólie) tvoří hygroskopické materiály, které jsou schopny absorbovat vlhkost z prostředí, přičemž z důvodu objemových změn dojde k oddělení fólie od podkladu, tj. k delaminaci. Takové chování je patrné ve vnitřních prostředích s dlouhodobě vysokou vzdušnou vlhkostí nebo ve vnějších i vnitřních prostředích v případě opakovaného smáčení mezilehlé vrstvy u hran.</p>



<p class="wp-block-paragraph" id="5-3-8"><strong>5.3.8</strong><br>Skleněné prvky prohříváren mají být navrženy z bezpečnostního skla s charakterem lomu typu&nbsp;C podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a>.</p>



<p class="wp-block-paragraph"><strong>5.3.9</strong><br>V případě návrhu jednoduchého tepelně tvrzeného bezpečnostního skla s charakterem lomu typu C podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a> pro prostory specifikované v <a href="#5-3-7">odst. 5.3.7</a> a <a href="#5-3-8">5.3.8</a> musí takové sklo odpovídat výrobkové normě ČSN&nbsp;EN&nbsp;14179 a horní hrana takového zasklení musí být ve výšce nižší než 4 metry nad pochozí plochou.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-4">5.4 VANDALISMUS</h3>



<p class="wp-block-paragraph" id="5-4-1"><strong>5.4.1</strong><br>Návrh skleněné konstrukce musí být proveden tak, aby konstrukce během své životnosti byla přiměřeně chráněna vůči vandalismu a proti poškození od uživatelů a zvířat.</p>



<p class="wp-block-paragraph" id="5-4-2"><strong>5.4.2</strong><br>Spodní hrana skleněného prvku ve vnějším prostředí má být osazena minimálně ve výšce&nbsp;400&nbsp;mm nad úrovní přilehlého vnějšího terénu pro minimalizaci rizika poškození skla během provozu. Spodní hrana skla nemá být níže než 150 mm nad terénem pro zajištění spolehlivého odvodnění a napojení hydroizolačního souvrství.</p>



<p class="wp-block-paragraph" id="5-4-3"><strong>5.4.3</strong><br>V bezprostřední blízkosti vnější pěší komunikace či zpevněných ploch má být sklo do výšky minimálně 2 000 mm, respektive 3 000 mm u staveb se shromažďovacími prostory, ze skla odpovídající bezpečnostní kategorii P2A nebo vyšší podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=60147&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;356</a>. Veškeré vodorovné i svislé hrany skla mají být chráněny. Zejména je doporučeno chránit nároží u lepeného zasklení do výšky 2 000 mm, resp. do výšky 3 000 mm u staveb se shromažďovacími prostory, nad přilehlým terénem.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-5">5.5 TEPLOTNÍ ŠOK</h3>



<p class="wp-block-paragraph" id="5-5-1"><strong>5.5.1</strong><br>Je-li navrženo zasklení s úpravou, která může způsobovat nadměrné zahřívání skla v době slunečního záření (např. tónovací a barevné fólie, malby, jiné neprůhledné a neprůsvitné prvky), dále je-li navrženo vnitřní nebo vnější stálé či pohyblivé stínění, nebo navrženy předměty a stavební konstrukce blíže než 400 mm od zasklení, doporučuje se posoudit odolnost navrženého zasklení vůči teplotnímu šoku.</p>



<p class="wp-block-paragraph" id="5-5-2"><strong>5.5.2</strong><br>Jednoduché či izolační zasklení v bezprostřední blízkosti tmavých ploch (např. střešní asfaltová krytina) se má posoudit na odolnost vůči teplotnímu šoku.</p>



<p class="wp-block-paragraph" id="5-5-3"><strong>5.5.3</strong><br>Je-li navržena u prosklené střechy či světlíku přilehlá skleněná svislá či šikmá plocha, která by mohla významným způsobem z důvodu odrazu světla a tepla ovlivňovat jednotlivé skleněné prvky, má se v návrhu posoudit odolnost navrženého zasklení vůči teplotnímu šoku.</p>



<p class="wp-block-paragraph" id="5-5-4"><strong>5.5.4</strong><br>Je-li navrženo opláštění fasády se zasklívací jednotkou umístěnou před stavební konstrukcí (např. stropní deska, sloup), musí být šířka vzniklého volného meziprostoru mezi zadním lícem zasklívací jednotky a předním lícem stavební konstrukce minimálně stejně široká, jako je výška takového meziprostoru, jak znázorňuje <a href="#obr-5">obr. 5</a>. Není-li možné dodržet doporučený poměr, má být posouzeno riziko teplotního šoku přilehlého zasklení.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-5"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-005.png"><img loading="lazy" decoding="async" width="392" height="436" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-005.png" alt="" class="wp-image-12966" style="width:auto;height:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-005.png 392w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-005-135x150.png 135w" sizes="(max-width: 392px) 100vw, 392px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 5</em> &nbsp;Poměr vzdálenosti zasklení od líce konstrukce podle výšky konstrukce</p>



<p class="wp-block-paragraph" id="5-5-5"><strong>5.5.5</strong><br>Není-li možné aplikace uvedené v <a href="#5-5-1">odst. 5.5.1</a> až <a href="#5-5-4">5.5.4</a> adekvátně teoreticky posoudit, má se u rizikových aplikací použít sklo se zvýšenou odolností proti teplotnímu šoku, zejména sklo tepelně zpevněné, tepelně tvrzené bezpečnostní sklo nebo prohřívané tepelně tvrzené bezpečnostní sklo.</p>



<p class="wp-block-paragraph" id="5-5-6"><strong>5.5.6</strong><br>Zasklení má být vzdáleno od přilehlých deskových otopných těles minimálně 300 mm pro sklo chlazené, 250 mm pro sklo tepelně zpevněné, 150 mm pro sklo tepelně tvrzené, jak je zobrazeno na <a href="#obr-6">obr. 6</a>.<sup><a href="#poznamka-21">21)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-21"><strong>Poznámka<sup>21)</sup>:</strong><br>Při navrhování jiných topných zařízení, jako jsou podlahové konvektory, kamna, dveřní clony apod., má být zohledněn návrhový výkon zařízení v kombinaci s rizikem teplotního šoku skleněného prvku. Takové aplikace je nutné posuzovat individuálně.</p>



<p class="wp-block-paragraph" id="5-5-7"><strong>5.5.7</strong><br>Je-li mezi zasklením a přilehlým deskovým otopným tělesem instalován kryt otopného tělesa (clonění), může být vzdálenost snížena o 50 mm. Kryt musí zajistit proudění teplého vzduchu směrem od skla.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-6"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-006.png"><img loading="lazy" decoding="async" width="797" height="293" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-006.png" alt="" class="wp-image-12967" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-006.png 797w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-006-150x55.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-006-768x282.png 768w" sizes="(max-width: 797px) 100vw, 797px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 6</em>&nbsp; Vzdálenost skleněného prvku od deskového otopného tělesa</p>



<p class="wp-block-paragraph" id="5-5-8"><strong>5.5.8</strong><br>Pokud není možné omezit vznik teplotního šoku stavebními úpravami, má se posoudit v projektové dokumentaci pro stavební povolení.</p>



<p class="wp-block-paragraph" id="5-5-9"><strong>5.5.9</strong><br>Při návrhu posuvných dveří, oken nebo jiných stěn s izolačním zasklením, kde při jejich užívání dochází ke vzájemnému překrytí křídel, má být použito prohřívané tepelně tvrzené sklo, a to na ty plochy, které jsou při otevřené poloze vzájemně překryté.<sup><a href="#poznamka-22">22)</a></sup> Plochy, které se nepřekrývají, mají být navrženy z takového materiálu, který odpovídá charakteru provozu. Tyto zásady jsou znázorněny na <a href="#obr-7">obr. 7</a>.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-22"><strong>Poznámka<sup>22)</sup>:</strong><br>Požadavek se neuplatňuje u aplikací, kde se nepředpokládá zatížení slunečním zářením či jiným významným zdrojem teplotního záření nebo tam, kde se výpočtem prokáže, že lze použít i jiný druh skla.</p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-7"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-007.png"><img loading="lazy" decoding="async" width="1520" height="649" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-007.png" alt="" class="wp-image-12968" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-007.png 1520w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-007-150x64.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-007-768x328.png 768w" sizes="(max-width: 1520px) 100vw, 1520px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 7</em>&nbsp; Použití skla u posuvných dveří, oken a jiných stěn</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="5-6">5.6 OSTATNÍ</h3>



<p class="wp-block-paragraph" id="5-6-1"><strong>5.6.1</strong><br>Při návrhu vrstveného bezpečnostního skla ve vnějším prostředí se má přihlížet k úrovni hygroskopie mezilehlé vrstvy s ohledem na riziko delaminace během provozu. Všechny hrany skleněného prvku z vrstveného bezpečnostního skla mají být chráněny vůči smáčení.<sup><a href="#poznamka-20">20)</a></sup></p>



<p class="wp-block-paragraph" id="5-6-2"><strong>5.6.2</strong><br>Návrh skleněného prvku s ohledem na jeho charakter lomu a v návaznosti na umístění a funkci prvku má být v souladu s Přílohou 1 tohoto standardu.</p>



<p class="wp-block-paragraph" id="5-6-3"><strong>5.6.3</strong><br>Veškeré skleněné prvky a jejich přidružené konstrukce musí být navrženy tak, aby nedocházelo k nadměrnému hromadění sněhu a ledu v jejich úžlabích a koutech, veškeré atmosférické srážky musí být spolehlivě odváděny. Není přípustné, aby vzniklo ledové propojení mezi sklem a pevnou přilehlou konstrukcí.<sup><a href="#poznamka-23">23)</a></sup></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-23"><strong>Poznámka<sup>23)</sup>:</strong><br>Ledovým propojením se rozumí zledovatělý usazený sníh, vzniklé ledové rampouchy, námraza, náledí. Neumožňuje-li povaha návrhu předcházet vzniku ledových propojení, doporučuje se navrhnout vyhřívání.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="6">6 DOKUMENTACE SKLENĚNÝCH PRVKŮ</h3>



<h3 class="wp-block-heading" id="6-1">6.1 POŽADAVKY NA PROJEKTOVOU DOKUMENTACI</h3>



<p class="wp-block-paragraph" id="6-1-1"><strong>6.1.1</strong><br>Při jakémkoliv použití skleněných prvků musí být vypracovaná dokumentace pro provádění stavby podle příslušného právního předpisu.<sup><a href="#poznamka-24">24)</a></sup> Další požadované podrobnosti zpracované dokumentace jsou uvedeny v této a v následující kapitole.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-24"><strong>Poznámka<sup>24)</sup>:</strong><br>Vyhláška <a rel="noopener noreferrer" href="https://e-sbirka.gov.cz/sb/2006/499?zalozka=text" target="_blank">č. 499/2006 Sb.</a></p>



<p class="wp-block-paragraph" id="6-1-2"><strong>6.1.2</strong><br>Užití skleněných prvků musí být řešeno již ve stupni dokumentace pro stavební povolení. V&nbsp;dokumentaci pro stavební povolení musí být uveden účel užívání prostor obsahující skleněné prvky a uvedeny návrhové hodnoty zatížení, kterým má skleněný prvek odolat. Skleněné prvky musí být v projektové dokumentaci pro stavební povolení na stanovené návrhové zatížení staticky posouzeny.</p>



<p class="wp-block-paragraph" id="6-1-3"><strong>6.1.3</strong><br>Součástí projektové dokumentace pro provádění stavby musí být statický výpočet, který musí zahrnovat i posouzení skleněných prvků.</p>



<p class="wp-block-paragraph" id="6-1-4"><strong>6.1.4</strong><br>Projektová dokumentace pro provádění stavby, obsahující skleněné prvky, musí být jednoznačná provozně, technicky i esteticky. Musí jednoznačně specifikovat materiálové a konstrukční řešení a rozhodující detaily. Navržené řešení musí být realizovatelné.</p>



<p class="wp-block-paragraph" id="6-1-5"><strong>6.1.5</strong><br>Při změnách je nutné postupovat podle stavebního zákona a jeho prováděcích předpisů.</p>



<p class="wp-block-paragraph" id="6-1-6"><strong>6.1.6</strong><br>Konstrukce se zábradelní funkcí, obsahující skleněný prvek, musí posoudit osoba oprávněná, podle zvláštního právního předpisu.<sup><a href="#poznamka-4">4)</a></sup> Na účinky statického a dynamického zatížení musí být zábradlí posouzeno jako celek v souladu s normou <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank">ČSN&nbsp;74&nbsp;3305</a>. Staticky posouzena musí být i samotná skleněná výplň při zohlednění jejího uchycení.<sup><a href="#poznamka-25">25)</a></sup> Není-li možné konstrukci se zábradelní funkcí, obsahující skleněný prvek, posoudit na účinky dynamického zatížení ve stupni dokumentace pro stavební povolení, je nutné předepsat rázovou zkoušku prosklené části podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank">ČSN&nbsp;74&nbsp;3305</a>, respektive podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=500794&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;14019</a>.</p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-25"><strong>Poznámka<sup>25)</sup>:</strong><br>Zábradelní výplň ze skla nemusí být staticky posouzena, jsou-li prosklené otvory dostatečně malé, jak ustanovuje <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank">ČSN&nbsp;74&nbsp;3305</a>. Zábradlí jako celek posouzeno být musí.</p>



<p class="wp-block-paragraph" id="6-1-7"><strong>6.1.7</strong><br>Technická specifikace návrhu</p>



<p class="wp-block-paragraph">Projektová dokumentace pro provádění stavby by měla specifikovat minimálně následující parametry skleněných prvků:</p>



<ul class="wp-block-list">
<li>návrhové zatížení a způsob využití dotčených prostor;</li>



<li>materiálová specifikace skla, tloušťka skla, úprava hran, druh a počet fólií, rozměry, koncepční způsob uchycení skleněných prvků;<sup><a href="#poznamka-26">26)</a></sup></li>



<li>statické posouzení a dynamické posouzení (kde je relevantní) zohledňující všechna návrhová zatížení a jejich kombinace, včetně posouzení uchycení.</li>
</ul>



<p class="wp-block-paragraph"></p>



<p class="is-style-odstavec-poznamka wp-block-paragraph" id="poznamka-26"><strong>Poznámka<sup>26)</sup>:</strong><br>Příklad materiálové specifikace: jednoduché vrstvené bezpečnostní sklo, skladba 88.2, 2x sklo prohřívané bezpečnostní tepelně tvrzené 8 mm + 2x PVB 0,38 mm, rozměry – 1,2 x 1,0 m, uchycení – podélně čtyřstranně.</p>



<p class="wp-block-paragraph" id="6-1-8"><strong>6.1.8</strong><br>Je-li nutná dokumentace zajišťovaná zhotovitelem (výrobní dokumentace), musí to být požadováno v projektové dokumentaci pro provádění stavby. Odpovědnost projektanta za správnost a úplnost projektové dokumentace pro provádění stavby jako celku tím není dotčena. Doporučuje se odsouhlasení této dokumentace projektantem.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="6-2">6.2 POŽADAVKY NA DOKUMENTACI ZAJIŠŤOVANOU ZHOTOVITELEM</h3>



<p class="wp-block-paragraph" id="6-2-1"><strong>6.2.1</strong><br>Z dokumentace zhotovitele musí být jednoznačně zřejmé řešení upevnění a napojení skleněného prvku na přilehlé stavební konstrukce. Musí být jednoznačně zřejmé veškeré dílčí prvky a jejich rozměry. Výrobní dokumentace by měla obsahovat výkresovou část, technické listy a certifikáty. Podkladem pro výrobní dokumentaci jsou předchozí stupně projektové dokumentace.</p>



<p class="wp-block-paragraph"><br></p>



<h2 class="wp-block-heading" id="6-3">6.3 PROVOZNÍ ŘÁDY, PLÁN KONTROL A ÚDRŽBY</h2>



<p class="wp-block-paragraph" id="6-3-1"><strong>6.3.1</strong><br>Pro všechny skutečně zabudované skleněné prvky, včetně jejich dílčích komponent, musí být stanoven plán údržby. Plán údržby má obsahovat režim prohlídek, kontrol, způsob údržby a obnovy. Takový plán údržby by měl být součástí provozního řádu budovy.</p>



<p class="wp-block-paragraph" id="6-3-2"><strong>6.3.2</strong><br>Pravidelné kontroly skleněných prvků mají být prováděny vizuálně, zejména má být kontrolována funkčnost, bezporuchovost a čistota skleněných prvků, bezvadnost uchycovacích mechanismů a požadovaná těsnost, kde je relevantní.</p>



<p class="wp-block-paragraph" id="6-3-3"><strong>6.3.3</strong><br>Běžná údržba zahrnuje zejména běžné opravy a výměnu skleněných prvků, včetně jejich dílčích komponent, odstraňování nečistot, sněhu a ledu, dále čištění skleněných prvků pro zachování návrhem požadovaných vlastností.</p>



<p class="wp-block-paragraph"><br></p>



<h3 class="wp-block-heading" id="7">7 LITERATURA, CITOVANÉ PŘEDPISY A NORMY</h3>



<p class="wp-block-paragraph" id="literatura-1">[1] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=502414&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;572-1+A1</a>: Sklo ve stavebnictví &#8211; Základní výrobky ze sodnovápenatokřemičitého skla &#8211; Část 1: Definice a obecné fyzikální a mechanické vlastnosti</p>



<p class="wp-block-paragraph" id="literatura-2">[2] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90679&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1863-1</a>: Sklo ve stavebnictví &#8211; Tepelně zpevněné sodnovápenatokřemičité sklo &#8211; Část 1: Definice a popis</p>



<p class="wp-block-paragraph" id="literatura-3">[3] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=90442&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;ISO 12543-1</a>: Sklo ve stavebnictví &#8211; Vrstvené sklo a vrstvené bezpečnostní sklo &#8211; Část 1: Definice a popis součástí</p>



<p class="wp-block-paragraph" id="literatura-4">[4] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=509508&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12150-1+A1</a>: Sklo ve stavebnictví &#8211; Tepelně tvrzené sodnovápenatokřemičité bezpečnostní sklo &#8211; Část 1: Definice a popis</p>



<p class="wp-block-paragraph" id="literatura-5">[5] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503536&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;14179-1</a>: Sklo ve stavebnictví &#8211; Prohřívané tepelně tvrzené sodnovápenatokřemičité bezpečnostní sklo &#8211; Část 1: Definice a popis</p>



<p class="wp-block-paragraph" id="literatura-6">[6] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503693&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;13119</a>: Lehké obvodové pláště &#8211; Terminologie</p>



<p class="wp-block-paragraph" id="literatura-7">[7] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=500663&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;74&nbsp;1901-1</a>: Navrhování střech &#8211; Část 1: Základní ustanovení</p>



<p class="wp-block-paragraph" id="literatura-8">[8] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=503279&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;74&nbsp;3305</a>: Ochranná zábradlí</p>



<p class="wp-block-paragraph" id="literatura-9">[9] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=500794&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;14019</a>: Lehké obvodové pláště &#8211; Odolnost proti nárazu &#8211; Funkční požadavky</p>



<p class="wp-block-paragraph" id="literatura-10">[10] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=89997&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;74&nbsp;4505</a>: Podlahy &#8211; Společná ustanovení</p>



<p class="wp-block-paragraph" id="literatura-11">[11] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=511483&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;16612</a>: Sklo ve stavebnictví &#8211; Stanovení pevnosti při příčném zatížení skleněných tabulí výpočtem</p>



<p class="wp-block-paragraph" id="literatura-12">[12] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=511193&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;16613</a>: Sklo ve stavebnictví &#8211; Vrstvené sklo a vrstvené bezpečnostní sklo &#8211; Stanovení viskoelastických vlastností mezivrstvy</p>



<p class="wp-block-paragraph" id="literatura-13">[13] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=60147&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;356</a>: Sklo ve stavebnictví &#8211; Bezpečnostní zasklení &#8211; Zkoušení a klasifikace odolnosti proti ručně vedenému útoku</p>



<p class="wp-block-paragraph" id="literatura-14">[14] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=59664&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1063</a>: Sklo ve stavebnictví &#8211; Bezpečnostní zasklení &#8211; Zkoušení a klasifikace odolnosti proti střelám</p>



<p class="wp-block-paragraph" id="literatura-15">[15] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a>: Sklo ve stavebnictví &#8211; Kyvadlová zkouška &#8211; Metoda zkoušení nárazem a klasifikace pro ploché sklo</p>



<p class="wp-block-paragraph" id="literatura-16">[16] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=69328&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1991-1-1</a>: Eurokód 1: Zatížení konstrukcí &#8211; Část 1-1: Obecná zatížení &#8211; Objemové tíhy, vlastní tíha a užitná zatížení pozemních staveb</p>



<p class="wp-block-paragraph" id="literatura-17">[17] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=72773&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1991-1-3</a>: Eurokód 1: Zatížení konstrukcí &#8211; Část 1-3: Obecná zatížení &#8211; Zatížení sněhem</p>



<p class="wp-block-paragraph" id="literatura-18">[18] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=77516&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1991-1-4</a>: Eurokód 1: Zatížení konstrukcí &#8211; Část 1-4: Obecná zatížení &#8211; Zatížení větrem</p>



<p class="wp-block-paragraph" id="literatura-19">[19] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=79645&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;1991-1-7</a>: Eurokód 1: Zatížení konstrukcí &#8211; Část 1-7: Obecná zatížení &#8211; Mimořádná zatížení</p>



<p class="wp-block-paragraph" id="literatura-20">[20] <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=95827&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;ISO&nbsp;15686-1</a>: Budovy a jiné stavby &#8211; Plánování životnosti &#8211; Část 1: Obecné principy a rámec</p>



<p class="wp-block-paragraph" id="literatura-21">[21] DIN&nbsp;18008-1: Glass in Building &#8211; Design and construction rules &#8211; Part 1: Terms and general bases. Překlad: Sklo ve stavebnictví &#8211; Návrh a konstrukční zásady &#8211; Část 1: Termíny a obecné zásady.</p>



<p class="wp-block-paragraph" id="literatura-22">[22] DIN&nbsp;18008-2: Glass in Building &#8211; Design and construction rules &#8211; Part 2: Linearly supported glazings. Překlad: Sklo ve stavebnictví &#8211; Návrh a konstrukční zásady &#8211; Část 2: Lineárně uložené zasklení.</p>



<p class="wp-block-paragraph" id="literatura-23">[23] DIN&nbsp;18008-3: Glass in Building &#8211; Design and construction rules &#8211; Part 3: Point fixed glazing. Překlad: Sklo ve stavebnictví &#8211; Návrh a konstrukční zásady &#8211; Část 3: Bodově uložené zasklení.</p>



<p class="wp-block-paragraph" id="literatura-24">[24] NEN&nbsp;2608: Glass in Building &#8211; Requirements and determination method. Překlad: Sklo ve stavebnictví &#8211; Požadavky a determinační metody.</p>



<p class="wp-block-paragraph" id="literatura-25">[25] ÖNORM&nbsp;B&nbsp;3716-1: Glass in building &#8211; Structural glass construction &#8211; Part 1: Basic principles. Překlad: Sklo ve stavebnictví &#8211; Skleněné konstrukce &#8211; Část 1: Základní požadavky.</p>



<p class="wp-block-paragraph" id="literatura-26">[26] ÖNORM&nbsp;B&nbsp;3716-2: Glass in building &#8211; Structural glass construction &#8211; Part 2: Linear glazings. Překlad: Sklo ve stavebnictví &#8211; Skleněné konstrukce &#8211; Část 2: Lineární zasklení.</p>



<p class="wp-block-paragraph" id="literatura-27">[27] ÖNORM&nbsp;B&nbsp;3716-3: Glass in building &#8211; Structural glass construction &#8211; Part 3: Vertical glazings with protective function against fall. Překlad: Sklo ve stavebnictví &#8211; Skleněné konstrukce &#8211; Část 3: Svislé zasklení s&nbsp;ochrannou funkcí proti pádu.</p>



<p class="wp-block-paragraph" id="literatura-28">[28] ÖNORM&nbsp;B&nbsp;3716-4: Glass in building &#8211; Structural glass construction &#8211; Part 4: Accessible, walkable and trafficable glazings. Překlad: Sklo ve stavebnictví &#8211; Skleněné konstrukce &#8211; Část 4: Přístupné, pochozí a dopravní zasklení.</p>



<p class="wp-block-paragraph" id="literatura-29">[29] ÖNORM&nbsp;B&nbsp;3716-7: Glass in building &#8211; Structural glass construction &#8211; Part 7: Applications for glass. Překlad: Sklo ve stavebnictví &#8211; Skleněné konstrukce &#8211; Část 7: Aplikace skla.</p>



<p class="wp-block-paragraph" id="literatura-30">[30] NF&nbsp;DTU&nbsp;39 P3: Building works &#8211; glazing and mirror-glass works &#8211; Part 3: Calculation memorandum for thermal stress. Překlad: Práce stavební &#8211; Zasklívání a práce sklenářské &#8211; Část 3: Metodika výpočtu teplotního namáhání.</p>



<p class="wp-block-paragraph" id="literatura-31">[31] ETAG 002: Systémy zasklení s&nbsp;konstrukčním tmelem &#8211; Část 1: Podepřené a nepodepřené systémy.</p>



<p class="wp-block-paragraph" id="literatura-32">[32] VFF Merkblatt V.02 Thermische Beanspruchung von Gläsern in Fenstern und Fassaden. Překlad: Teplotní namáhání zasklení v&nbsp;oknech a fasádách.</p>



<p class="wp-block-paragraph" id="literatura-33">[33] OIB-330.4-020/19 &#8211; OiB Richtlinie 4: Nutzungssicherheit und Barrierefreiheit. Překlad: Bezpečnost a přístupnost.</p>



<p class="wp-block-paragraph" id="literatura-34">[34] DGUV Regel 107-001: Betrieb von Bädern. Překlad: Provoz koupališť.</p>



<p class="wp-block-paragraph"><s><br></s></p>



<h3 class="wp-block-heading" id="priloha-1">PŘÍLOHA 1 – POŽADOVANÝ CHARAKTER LOMU SKLA PRO KONKRÉTNÍ APLIKACE</h3>



<p class="wp-block-paragraph" id="tab-p1-1"><em>Tab. P1.1</em> &nbsp;Požadovaný charakter lomu skla pro otvorové výplně a LOP</p>



<figure class="wp-block-table">
<table>
<thead>
<tr>
<td style="vertical-align: middle; background-color: #cccccc;" rowspan="3">Podoblast</td>
<td style="vertical-align: middle; background-color: #cccccc;" colspan="2" rowspan="3">Bližší specifikace skleněného prvku</td>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;" rowspan="3">Schéma</td>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;" colspan="4">Charakter lomu podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a></td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;" rowspan="2">Jednotabulové sklo</td>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;" colspan="3">Izolační sklo</td>
</tr>
<tr>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;">Tabule ve vnitřním prostředí</td>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;">Tabule ve vnějším prostředí</td>
<td style="text-align: center; vertical-align: middle; background-color: #cccccc;">Tabule středové</td>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Otvorové výplně – dveře</td>
<td rowspan="2">Dveře se skleněnou výplní</td>
<td>Spodní hrana skla&nbsp;≥&nbsp;1,5&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-8">Obr. 8</a>, 1a)</td>
<td style="text-align: center;" colspan="3">A, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Spodní hrana skla &lt;&nbsp;1,5&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-8">Obr. 8</a>, 1b)</td>
<td style="text-align: center;" colspan="3">B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Dveře celoskleněné</td>
<td>&#8211;</td>
<td style="text-align: center;"><a href="#obr-8">Obr. 8</a>, 1c)</td>
<td style="text-align: center;">B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;" colspan="3">&#8211;</td>
</tr>
<tr>
<td rowspan="12">Okenní otvorové výplně a LOP</td>
<td rowspan="2">Okno otevíravé s výškou horní hrany zasklení nad přilehlým terénem <em>h</em><sub>1</sub> &lt;&nbsp;4,0&nbsp;m</td>
<td>Spodní hrana skla nad podlahou ≥&nbsp;0,85&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-9">Obr. 9</a>, 2a)</td>
<td style="text-align: center;" colspan="3">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Spodní hrana skla nad podlahou &lt;&nbsp;0,85&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-9">Obr. 9</a>, 2b)</td>
<td style="text-align: center;">B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td rowspan="4">Okno otevíravé s výškou horní hrany zasklení nad přilehlým terénem <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m</td>
<td>Spodní hrana skla nad podlahou ≥&nbsp;0,85&nbsp;m a vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub> &lt; 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1</sub> &lt;<em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku &gt; <em>h</em><sub>1</sub> 30 m</td>
<td style="text-align: center;"><a href="#obr-9">Obr. 9</a>, 2c)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Spodní hrana skla nad podlahou &lt;&nbsp;0,85&nbsp;m a vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub>&nbsp;&lt; 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1</sub> &lt; <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku &gt; 30 m</td>
<td style="text-align: center;"><a href="#obr-9">Obr. 9</a>, 2d)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Okno navazující na předsazenou vnější konstrukci, kdy hrana skla je ve vzdálenosti <em>b</em><sub>2</sub>&nbsp;≥&nbsp;2,0&nbsp;m od hrany volného prostoru, u níž je výška od&nbsp;úrovně terénu k hornímu okraji hrany skla <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m a výška horní hrany skla <em>h</em><sub>2</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m nad úrovní předsazené konstrukce; nebo vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub> ≥ 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1</sub> <em>≥ h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt; 30 m</td>
<td style="text-align: center;"><a href="#obr-11">Obr.&nbsp;11</a>, 2e<sub>1</sub>)<br><a href="#obr-11">Obr.&nbsp;11</a>, 2e<sub>2</sub>)</td>
<td style="text-align: center;" colspan="2">Podle <a href="#obr-9">obr. 9</a>, 2c), resp. 2d)</td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Svislé zasklení, jehož plocha 1 tabule skla <em>A</em>&nbsp;&lt;&nbsp;2,0&nbsp;m<sup>2</sup></td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;" colspan="2">Podle <a href="#obr-9">obr. 9</a>, 2a), resp. 2b)</td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td rowspan="2">Fixní zasklení s&nbsp;výškou horní hrany zasklení nad přilehlým terénem <em>h</em><sub>1</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m</td>
<td>Bez zábradelní funkce, spodní hrana skla nad podlahou&nbsp;≥&nbsp;0,85&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-10">Obr. 10</a>, 2f)</td>
<td style="text-align: center;" colspan="3">A<sup>1)</sup>, B, C<sup>2)</sup></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Se zábradelní funkcí, spodní hrana skla nad podlahou&nbsp;&lt;&nbsp;0,85&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-10">Obr. 10</a>, 2g)</td>
<td style="text-align: center;" colspan="2">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td rowspan="4">Fixní zasklení s&nbsp;výškou horní hrany zasklení nad přilehlým terénem <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m</td>
<td>Bez zábradelní funkce a spodní hrana skla nad podlahou&nbsp;≥&nbsp;0,85&nbsp;m a&nbsp;vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub>&nbsp;&lt;&nbsp;2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1 </sub>&lt;<em> h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1&nbsp;</sub>&gt; 30 m</td>
<td style="text-align: center;"><a href="#obr-10">Obr. 10</a>, 2h)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Se zábradelní funkcí nebo spodní hrana skla nad podlahou&nbsp;&lt;&nbsp;0,85&nbsp;m a vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub>&nbsp;&lt; 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1</sub> &lt;<em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt;&nbsp;30&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-10">Obr. 10</a>, 2i)</td>
<td style="text-align: center;" colspan="2">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Zasklení navazující na předsazenou vnější konstrukci, kdy hrana skla je ve vzdálenosti <em>b</em><sub>2</sub>&nbsp;≥&nbsp;2,0&nbsp;m od hrany volného prostoru, u níž je výška od úrovně terénu k hornímu okraji hrany skla <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m a výška horní hrany skla <em>h</em><sub>2</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m nad úrovní předsazené konstrukce; nebo vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub>&nbsp;≥ 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30 m; nebo<em> b</em><sub>1</sub>&nbsp;<span class="ILfuVd" lang="en"><span class="hgKElc"><b>≥</b></span></span> <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt;&nbsp;30&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-11">Obr. 11</a>, 2j<sub>1</sub>)<br><a href="#obr-12">Obr. 12</a>, 2j<sub>2</sub>)</td>
<td style="text-align: center;" colspan="2">Podle <a href="#obr-10">obr. 10</a>, 2h), resp. 2i)</td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Svislé zasklení, jehož plocha 1 tabule skla <em>A</em> &lt; 2,0 m<sup>2</sup></td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;" colspan="2">Podle <a href="#obr-10">obr. 10</a>, 2f), resp. 2g)</td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph"><br>Schémata k&nbsp;<a href="#tab-p1-1">tab. P1.1</a></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-8"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-008.png"><img loading="lazy" decoding="async" width="1092" height="559" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-008.png" alt="" class="wp-image-12969" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-008.png 1092w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-008-150x77.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-008-768x393.png 768w" sizes="(max-width: 1092px) 100vw, 1092px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 8</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-9"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009.png"><img loading="lazy" decoding="async" width="1636" height="759" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009.png" alt="" class="wp-image-20284" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009.png 1636w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009-150x70.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009-768x356.png 768w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-009-1536x713.png 1536w" sizes="(max-width: 1636px) 100vw, 1636px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 9</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-10"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010.png"><img loading="lazy" decoding="async" width="1616" height="758" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010.png" alt="" class="wp-image-20285" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010.png 1616w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010-150x70.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010-768x360.png 768w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-010-1536x720.png 1536w" sizes="(max-width: 1616px) 100vw, 1616px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 10</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-11"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-011.png"><img loading="lazy" decoding="async" width="1266" height="992" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-011.png" alt="" class="wp-image-12972" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-011.png 1266w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-011-150x118.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-011-768x602.png 768w" sizes="(max-width: 1266px) 100vw, 1266px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 11</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-12"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-012.png"><img loading="lazy" decoding="async" width="938" height="729" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-012.png" alt="" class="wp-image-20286" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-012.png 938w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-012-150x117.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-012-768x597.png 768w" sizes="(max-width: 938px) 100vw, 938px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 12</em>&nbsp;</p>



<p class="wp-block-paragraph" id="tab-p1-2"><em>Tab. P1.2</em>&nbsp; Požadovaný charakter lomu skla pro příčky</p>



<figure class="wp-block-table">
<table>
<thead>
<tr>
<td style="background-color: #cccccc; vertical-align: middle;" rowspan="3">Podoblast</td>
<td style="background-color: #cccccc; vertical-align: middle;" colspan="2" rowspan="3">Bližší specifikace skleněného prvku</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" rowspan="3">Schéma</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" colspan="3">Charakter lomu podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a></td>
</tr>
<tr>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" rowspan="2">Jednotabulové sklo</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" colspan="2">Izolační sklo</td>
</tr>
<tr>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Tabule okrajová pozice&nbsp;1</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Tabule okrajová pozice&nbsp;2</td>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="2">Příčky</td>
<td rowspan="2">Vnitřní a vnější příčky celoskleněné nebo příčky se skleněnou výplní</td>
<td>Bez zábradelní funkce a horní hrana skla <em>h</em><sub>1</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m nad pochozí plochou nebo hrana skla je ve vzdálenosti b<sub>2</sub>&nbsp;≥&nbsp;2,0&nbsp;m od hrany volného prostoru, u níž je výška <em>h</em><sub>1</sub> od úrovně terénu k&nbsp;hornímu okraji hrany skla&nbsp;≥&nbsp;4,0&nbsp;m a&nbsp;výška horní hrany skla <em>h</em><sub>2</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m nad úrovni předsazené konstrukce; nebo vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub> ≥ 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30m; nebo <em>b</em><sub>1</sub> ≥ <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt; 30 m</td>
<td style="text-align: center;"><a href="#obr-13">Obr. 13</a>, 3a<sub>1</sub>)<br><a href="#obr-14">Obr. 14</a>, 3a<sub>2</sub>)</td>
<td style="text-align: center;">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
<td style="text-align: center;" colspan="2">A<a href="#priloha-poznamka-1"><sup>1)</sup></a>, B, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
</tr>
<tr>
<td>Se zábradelní funkcí nebo horní hrana skla <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m nad&nbsp;pochozí plochou nebo hrana skla je ve vzdálenosti <em>b</em><sub>2</sub>&nbsp;&lt;&nbsp;2,0&nbsp;m od&nbsp;hrany volného prostoru, u&nbsp;níž je výška <em>h</em><sub>1</sub> od úrovně terénu k&nbsp;hornímu okraji hrany skla&nbsp;≥&nbsp;4,0&nbsp;m a vzdálenost veřejně přístupných pochozích ploch a&nbsp;komunikací <em>b</em><sub>1</sub> &lt; 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30m; nebo <em>b</em><sub>1</sub> &lt; <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt; 30 m</td>
<td style="text-align: center;"><a href="#obr-15">Obr. 15</a>, 3b)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
<td style="text-align: center;">A<sup><a href="#priloha-poznamka-1">1)</a> <a href="#priloha-poznamka-4">4)</a></sup>, B</td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph"><br>Schémata k <a href="#tab-p1-2">tab. P1.2</a></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-13"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-013.png"><img loading="lazy" decoding="async" width="1180" height="688" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-013.png" alt="" class="wp-image-12974" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-013.png 1180w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-013-150x87.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-013-768x448.png 768w" sizes="(max-width: 1180px) 100vw, 1180px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 13</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-14"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-014.png"><img loading="lazy" decoding="async" width="870" height="755" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-014.png" alt="" class="wp-image-20287" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-014.png 870w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-014-150x130.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-014-768x666.png 768w" sizes="(max-width: 870px) 100vw, 870px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 14</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-15"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-015.png"><img loading="lazy" decoding="async" width="1336" height="736" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-015.png" alt="" class="wp-image-20288" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-015.png 1336w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-015-150x83.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-015-768x423.png 768w" sizes="(max-width: 1336px) 100vw, 1336px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 15</em>&nbsp;</p>



<p class="wp-block-paragraph" id="tab-p1-3"><em>Tab. P1.3</em>&nbsp; Požadovaný charakter lomu skla zábradlí a skleněný obklad</p>



<figure class="wp-block-table">
<table border="1">
<thead>
<tr>
<td style="background-color: #cccccc; vertical-align: middle;" rowspan="2">Podoblast</td>
<td style="background-color: #cccccc; vertical-align: middle;" colspan="2" rowspan="2">Bližší specifikace skleněného prvku</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" rowspan="2">Schéma</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" colspan="2">Charakter lomu podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a></td>
</tr>
<tr>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Jednotabulové sklo</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Izolační sklo (tabule nad volným prostorem)</td>
</tr>
</thead>
<tbody>
<tr>
<td>Zábradlí</td>
<td>Zábradlí se skleněnou výplní a celoskleněné (vnitřní i&nbsp;vnější prostředí)</td>
<td>Hloubka volného prostoru&nbsp;≥&nbsp;0,3&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-16">Obr. 16</a>, 4a)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a> <a href="#priloha-poznamka-5"><sup>5)</sup></a></td>
<td style="text-align: center;">&#8211;</td>
</tr>
<tr>
<td rowspan="2">Obklad</td>
<td rowspan="2">Svislé, šikmé a vodorovné vnější a vnitřní obkladové prvky ze skla</td>
<td>Horní hrana skla nad volným terénem či pochozí plochou je ve výšce <em>h</em><sub>1</sub>&nbsp;&lt;&nbsp;4,0&nbsp;m nebo vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub> ≥ 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30m; nebo <em>b</em><sub>1</sub> <span class="ILfuVd" lang="en"><span class="hgKElc"><b>≥</b></span></span> <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt;&nbsp;30&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-17">Obr.&nbsp;17</a>, 5a)</td>
<td style="text-align: center;" colspan="2">A<a href="#priloha-poznamka-4"><sup>4)</sup></a> <a href="#priloha-poznamka-6"><sup>6)</sup></a>, B<a href="#priloha-poznamka-3"><sup>3)</sup></a>, C<a href="#priloha-poznamka-2"><sup>2)</sup></a></td>
</tr>
<tr>
<td>Horní hrana skla nad volným terénem či pochozí plochou je ve výšce <em>h</em><sub>1</sub>&nbsp;≥&nbsp;4,0&nbsp;m a vzdálenost veřejně přístupných pochozích ploch a komunikací <em>b</em><sub>1</sub> &lt; 2,5 m je-li <em>h</em><sub>1</sub> ≤ 30m; nebo <em>b</em><sub>1</sub> &lt; <em>h</em><sub>1</sub>/10 je-li horní hrana skleněného prvku <em>h</em><sub>1</sub> &gt;&nbsp;30&nbsp;m</td>
<td style="text-align: center;"><a href="#obr-18">Obr.&nbsp;18</a>, 5b)</td>
<td style="text-align: center;" colspan="2">A<a href="#priloha-poznamka-4"><sup>4)</sup></a> <a href="#priloha-poznamka-6"><sup>6)</sup></a>, B<a href="#priloha-poznamka-3"><sup>3)</sup></a></td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph">Schémata k <a href="#tab-p1-3">tab. P1.3</a></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr16"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-016.png"><img loading="lazy" decoding="async" width="788" height="544" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-016.png" alt="" class="wp-image-12977" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-016.png 788w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-016-150x104.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-016-768x530.png 768w" sizes="(max-width: 788px) 100vw, 788px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 16</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-17"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-017.png"><img loading="lazy" decoding="async" width="777" height="667" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-017.png" alt="" class="wp-image-20289" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-017.png 777w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-017-150x129.png 150w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-017-768x659.png 768w" sizes="(max-width: 777px) 100vw, 777px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 17</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-18"><a href="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-018.png"><img loading="lazy" decoding="async" width="366" height="707" src="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-018.png" alt="" class="wp-image-20290" style="width:auto;height:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-018.png 366w, https://profesis.ckait.cz/wp-content/uploads/2024/04/ts-03-v-2024-obr-018-78x150.png 78w" sizes="(max-width: 366px) 100vw, 366px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 18<br></em></p>



<p class="wp-block-paragraph" id="tab-p1-4"><em>Tab. P1.4</em>&nbsp; Požadovaný charakter lomu skla pro pochozí a nepochozí plochy</p>



<figure class="wp-block-table">
<table>
<thead>
<tr>
<td style="background-color: #cccccc; vertical-align: middle;" rowspan="3">Podoblast</td>
<td style="background-color: #cccccc; vertical-align: middle;" colspan="2" rowspan="3">Bližší specifikace skleněného prvku</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" rowspan="3">Schéma</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" colspan="4">Charakter lomu podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN EN 12600</a></td>
</tr>
<tr>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" rowspan="2">Jednotabulové sklo</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;" colspan="3">Izolační sklo</td>
</tr>
<tr>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Tabule okrajová pozice 1</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Tabule okrajová pozice 2</td>
<td style="text-align: center; background-color: #cccccc; vertical-align: middle;">Tabule středové</td>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="2">Nepochozí plochy</td>
<td>Prosklené zastřešení vnější i vnitřní</td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;"><a href="#obr-19">Obr. 19</a>, 6a)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a> <a href="#priloha-poznamka-7"><sup>7)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a> <a href="#priloha-poznamka-7"><sup>7)</sup></a></td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a>, C<a href="#priloha-poznamka-2"><sup>2)</sup></a>, (A)<a href="#priloha-poznamka-8"><sup>8)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
<tr>
<td>Prosklené přístřešky vnější i vnitřní</td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;"><a href="#obr-19">Obr. 19</a>, 6b)</td>
<td style="text-align: center;">B<a href="#priloha-poznamka-3"><sup>3)</sup></a> <a href="#priloha-poznamka-7"><sup>7)</sup></a></td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;">&#8211;</td>
</tr>
<tr>
<td>Pochozí plochy</td>
<td>Prosklené plochy vnější i vnitřní</td>
<td style="text-align: center;">&#8211;</td>
<td style="text-align: center;"><a href="#obr-20">Obr. 20</a>, 6c)</td>
<td style="text-align: center;" colspan="3">B<a href="#priloha-poznamka-3"><sup>3)</sup></a> <a href="#priloha-poznamka-9"><sup>9)</sup></a></td>
<td style="text-align: center;">A, B, C</td>
</tr>
</tbody>
</table>
</figure>



<p class="wp-block-paragraph"><br>Schémata k <a href="#tab-p1-4">tab. P1.4</a></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-19"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-019.png"><img loading="lazy" decoding="async" width="797" height="595" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-019.png" alt="" class="wp-image-12980" style="width:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-019.png 797w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-019-150x112.png 150w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-019-768x573.png 768w" sizes="(max-width: 797px) 100vw, 797px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 19</em></p>


<div class="wp-block-image">
<figure class="aligncenter size-full is-resized" id="obr-20"><a href="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-020.png"><img loading="lazy" decoding="async" width="511" height="785" src="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-020.png" alt="" class="wp-image-12981" style="width:auto;height:400px" srcset="https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-020.png 511w, https://profesis.ckait.cz/wp-content/uploads/2022/03/ts-03-v-2022-obr-020-98x150.png 98w" sizes="(max-width: 511px) 100vw, 511px" /></a></figure>
</div>


<p class="wp-block-paragraph"><em>Obr. 20&nbsp; </em><em><br></em></p>



<p class="wp-block-paragraph"><strong>Vysvětlující dodatky k&nbsp;<a href="#tab-p1-1">tab. P1.1</a> až <a href="#tab-p1-4">P1.4</a>:</strong></p>



<p class="wp-block-paragraph" id="priloha-poznamka-1"><sup>1)</sup> Použití skel s&nbsp;charakterem lomu A podle <a rel="noopener noreferrer" href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank">ČSN&nbsp;EN&nbsp;12600</a> u přilehlých pochozích ploch jak ve vnitřním, tak vnějším prostředí, omezují dále požadavky zvláštních právních a technických předpisů, zejména vyhlášky <a rel="noopener noreferrer" href="https://e-sbirka.gov.cz/sb/2009/398?zalozka=text" target="_blank">č. 398/2009 Sb.</a> a <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=504184&amp;cid=5" target="_blank" rel="noreferrer noopener">ČSN&nbsp;74&nbsp;7250</a>.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-2"><sup>2)</sup> Použití skla s charakterem lomu C podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a> je podmíněno použitím skla s Heat Soak Testem podle ČSN&nbsp;EN&nbsp;14179.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-3"><sup>3)</sup> Vrstvené bezpečnostní sklo s mezilehlou fólií nelze nahradit dodatečně lepenou fólií z vnější strany skla, nebudou-li výrobcem deklarovány vlastnosti odpovídající vrstvenému bezpečnostnímu sklu s&nbsp;mezilehlou fólií.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-4"><sup>4)</sup> Sklo s&nbsp;charakterem lomu A podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a> může být použito pouze v&nbsp;případech, kde není technicky možné použít sklo s&nbsp;charakterem lomu B podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a>. Použití skla s&nbsp;charakterem lomu A podle ČSN&nbsp;EN 12600 je podmíněno použitím skla tepelně zpevněného podle ČSN&nbsp;EN&nbsp;1863.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-5"><sup>5)</sup> Při použití pouze tepelně tvrzeného bezpečnostního skla a prohřívaného tepelně tvrzeného bezpečnostního skla v&nbsp;kombinaci s&nbsp;fólií PVB či EVA má být zohledněno riziko současného kolapsu všech dílčích tabulí v&nbsp;rámci vrstveného bezpečnostního skla. Má být navrženo takové uchycení, které spolehlivě zabrání vypadnutí skla při současném kolapsu všech dílčích tabulí vrstveného skla. Hrany mají být chráněny před poškozením.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-6"><sup>6)</sup> Aplikace je podmíněna čtyřstranně podélným uložením skleněného prvku.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-7"><sup>7)</sup> Nejedná-li se o prostor nad veřejným nebo shromažďovacím prostorem, může být použito i jednovrstvé sklo s&nbsp;drátěnou vložkou. Při aplikaci skla s&nbsp;drátěnou vložkou mají být zohledněna rizika v&nbsp;případě kolapsu takového skla.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-8"><sup>8)</sup> Použití jednovrstvého monolitického skla s&nbsp;charakterem lomu A podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a> na vnější pozici nepochozího izolačního skla je přípustné, ale nedoporučuje se z&nbsp;důvodu nižší odolnosti vůči klimatickým vlivům.</p>



<p class="wp-block-paragraph" id="priloha-poznamka-9"><sup>9)</sup> Pochozí sklo má být navrženo z&nbsp;vrstveného bezpečnostního skla s&nbsp;charakterem lomu B podle <a href="http://seznamcsn.agentura-cas.cz/login.aspx?k=67976&amp;cid=5" target="_blank" rel="noopener noreferrer">ČSN&nbsp;EN&nbsp;12600</a>, přičemž u skla na pozici nášlapné vrstvy má být zohledněna odolnost vůči návrhovému provozu (otěr, vryp).</p>



<p class="wp-block-paragraph"><br></p>



<p class="wp-block-paragraph"><strong>Obecně k&nbsp;<a href="#tab-p1-1">tab. P1.1</a> až <a href="#tab-p1-4">P1.4</a>:</strong></p>



<p class="wp-block-paragraph">V&nbsp;případě aplikace skleněných prvků s&nbsp;horní hranou výše než 4 m nad přilehlým terénem či plochou, se významně zvyšuje riziko ohrožení života a zdraví osob a zvířat, dále ohrožení majetku, při kolapsu skleněného prvku s&nbsp;charakterem lomu A nebo C. Z&nbsp;tohoto důvodu se má u takových aplikací navrhovat sklo s&nbsp;charakterem lomu B, které má předpoklad zůstat v&nbsp;konstrukci po nezbytně nutnou dobu, tzn.&nbsp;do&nbsp;doby výměny za prvek nový nebo bezpečný dočasný. Nepostupuje-li návrh podle předchozí věty, doporučuje se zpracovat analýzu rizik, která posoudí, že případný kolaps skleněného prvku nemůže ohrozit život a zdraví osob a zvířat, a ohrožení majetku je zanedbatelné.</p>



<p class="wp-block-paragraph">Výše uvedené požadavky platí obecně. Pro speciální aplikace (např. budovy škol, bazény, budovy zatížené vandalismem apod.) platí dodatečné požadavky plynoucí z obecných právních předpisů a ze základního znění technického standardu.</p>



<p class="wp-block-paragraph">Požadovaný charakter lomu skla pro konkrétní aplikace, zmíněný v této příloze, nenahrazuje potřebu statického posouzení skleněných prvků. Veškeré použité skleněné prvky musí být samostatně dimenzovány v&nbsp;projektové dokumentaci.</p>